July 2020 |
Page
30
NSW/WA/SA/ACT
02 8708 4400
VIC/TAS
03 8773 5300
QLD/NT
07 3442 6200
www.
acprod
.com.au
Product & Installation Manual: MAX-Tension
TM
TL-2
Walk-Up Inspection
Item
Comment
Damage caused by vehicle impacts
Minor damage caused by impacts from roadside
maintenance equipment
Misalignment
Missing components
Damage from vandalism
Sagging cables
Clear and dispose of any debris in and around the
system
Cutting tooth is in correct position
Disengaged friction plate
Frayed cable
Grading around system
Loose hardware
The cable sleeves shall rest a minimum of 150mm below
the impact head
Inspector signature
Date
Print Name
Location
If any of the above items are identified during the walk-up inspection, swift action should be taken
to repair and return the MAX-Tension™ TL-2 Guardrail Terminal System (MAX TL-2) to the proper
condition as outlined in this manual.