background image

Revised A: 10/24/22

Page 2 of 18

Part #: 6216-011-000

Important:  Some  options  may  slightly  alter  installation. To  ensure  proper  installation 
review the manual thoroughly and verify rough-ins before beginning any work. File this 
manual with the owner or maintenance personnel upon completion of installation.

Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall 
anchors and wall anchoring hardware must be appropriate for wall construction, and 
have a minimum pull-out rating of 1000 lbs. (453.6 kg).

ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the 
local code authority and is the responsibility of the installer for verification.

Single Temp Valve Assembly: Recommended working water pressure is 30 PSI (2.07 
bars)  minimum  to  100  PSI  (6.89  bars)  maximum.  Maximum  temperature  is  130°F 
(54.4°C).  Maximum  outlet  temperature  is  recommended  is  105°F  (40.6°C).  Valve 
assembly  must  be  drained  prior  to  being  subjected  to  freezing  temperatures.  A 
checkstop is provided with this valve assembly.

T/P Mixing Valve Assembly: Recommended working water pressure is 30 PSI (2.07 
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum hot water temperature is 
180°F  (82°C).  Temperature  adjustment  range  is  95°F-110°F  (43°C-48°C).  Valve 
assembly must be drained prior to being subjected to freezing temperatures. The valve 
assembly has a check integral to the inlet however, angle stop is to be provided by the 
installer.

Prior to installation, supply lines must be flushed of all foreign material such as pipe 
dope, chips, or solder. Debris or foreign material in water supply may damage valve.

Teflon tape is recommended on all threaded waste and supply connections to reduce the 
possibility of leaks.

Provide:  110-120  VAC/60Hz/3A  (MAX)  electrical  receptacle  for  factory  supplied 
120VAC/9VDC, 100mA plug-in transformer when -SO and -SOS options are selected.

Provide:  110-120  VAC/60Hz/15A  dedicated  circuit  when  Dyson  Air  Blade  Faucet 
selected. Refer to Dyson installation instructions  for more information. 

NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth 
grounded per N.E.C. (National Electrical Code). 

INSTALLATION, OPERATION 

& MAINTENANCE MANUAL

 NEO-METRO FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

Summary of Contents for NEO-METRO SLAB-EDGE 3802

Page 1: ...riate Tools Part 6216 011 000 Revised A 10 24 22 Page 1 of 18 TABLE OF CONTENTS Prior to Installation 2 Accessibility Comparison 3 Dimensional Data 4 Rough Ins 5 Installation 6 12 Finished Layouts 13...

Page 2: ...bly T P Mixing Valve Assembly Recommended working water pressure is 30 PSI 2 07 bars minimum to 100 PSI 6 89 bars maximum Maximum hot water temperature is 180 F 82 C Temperature adjustment range is 95...

Page 3: ...33 4 34 RIM MAX 27 17 9 22 33 4 31 RIM MAX 27 17 9 22 33 4 17 9 34 RIM MAX 22 33 4 34 RIM MAX 17 9 ADA PROFILE CBC PROFILE OBC PROFILE ADA PROFILE OBC Ontario Building Code CBC California Building Cod...

Page 4: ...DIMENSIONAL DATA 56 22 17 Revised A 10 24 22 Page 4 of 18 Part 6216 011 000 INSTALLATION OPERATION MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863...

Page 5: ...all Anchoring 9 16 Mounting Hole Support Bracket Mounting 2 Places I Wall Anchoring 3 8 x 3 4 Long Trap Cover Mounting Slots 2 Places J Supply Stub Out with Stop for Valve 1 2 NPSM Tempered Supply Inl...

Page 6: ...tional MC Mounting Carrier plus consideration for fixture Water Supply and Waste Piping 261 4 667 251 2 648 7 177 181 2 470 6 152 6 152 A 4 102 FINISHED FLOOR 61 2 165 4 102 23 4 70 4 102 SQ 4X 9 16 1...

Page 7: ...wall using 1 2 mounting hardware supplied by others Assemble deck to P Trap enclosure using the 1 4 20 hardware 2provided 6 places 1 4 20 UNC X 1 2 HEX HEAD CAP SCREW PROVIDED 1 4 MOUNTING BOLTS PROVI...

Page 8: ...Assemble waste piping using teflon tape on all 5threaded connections and make up waste connections to 1 1 2 P Trap HINT Teflon tape is recommended on all threaded waste and supply connections NOTE ADD...

Page 9: ...ng ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting 1 Cut t...

Page 10: ...water temperature at outlet If water is not at desired temperature adjust as necessary 1 Loosen locknut 2 Turn on fixture and run water for at least 2 minutes Allow supply temperature to stabilize 3 T...

Page 11: ...per tubing connection Timing Screw To adjust timing turn timing screw HAND OPERATION CONNECTIONS Turn timing screw clockwise to increase timing Do not over tighten ferrule nuts Revised A 10 24 22 Page...

Page 12: ...to soap filler assembly and soap reservoir with provided hose clamps C Install soap dispenser s onto deck NOTE Gasket and Washer are located beneath the deck D Attach 3 8 O D Tubing to the dispenser...

Page 13: ...HED LAYOUTS SHOWN FOR REFERENCE Revised A 10 24 22 Page 13 of 18 Part 6216 011 000 INSTALLATION OPERATION MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 8...

Page 14: ...lean with scale remover solution or pressurized air Debris or scale in diaphragm Remove diaphragm and clean Sensor flashes once when user s hands are within range Remove strainer and clean CONDITION F...

Page 15: ...riser tubing is crimped Straighten valve riser tubing Debris or scale in checkstop strainer Remove checkstop strainer and clean Blockage in valve flow control Remove blockage Low water pressure at su...

Page 16: ...h polishing surfaces RECOMMENDED CLEANING MATERIALS Sponge natural or artificial Nylon or other soft bristle material brush Soft cloth as used on automobile finishes RECOMMENDED CLEANING SOLUTIONS Han...

Page 17: ...1070 Mixing Valve Assembly 2598 202 001 2598 302 001 Description Part No Diagram SO VALVE AND SPOUT DETAILS 3802 SO Binho Industrial Sensor Operated Spout 9VDC provided with Power Supply and Battery P...

Page 18: ...ap Waste Assembly 4970 040 003 Trap Enclosure 6216 200 002 ENCLOSURES NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 PDM SOAP OPTION Soap Filler Assembly 1391 008 0...

Reviews: