GENERAL DESCRIPTION OF BASyC
™
• Non-proprietary Honeywell NiagaraAX framework hardware and software to achieve stand-alone,
computerized control of the recirculating domestic hot water system.
• Web browser capability and can be accessed 1) via the user’s LAN, 2) via the portable LCD display
3) via the integral BAS adapter or 4) via the internet using VPN interface. In all cases, no special
software is required.
• Real-time temperature, pressure and flow monitoring.
• Alarms and Alerts to multiple users via email and/or text.
• Data logging with data transfer capabilities through the user’s LAN or BAS interface.
• A highly customizable report generator with the ability to export the data to a pdf, HTML, TEXT
or CSV file for analysis beyond BASyC’s powerful internal capabilities
• Internal BAS adapters for BACnet, Lonworks, ModBus or oBIX without external adapters or gateways.
• Primary and Secondary LAN adapters with full isolation from each other
• Internal RS-232 and RS-485 adapters
• The capability of 34 inputs/outputs: 16 universal inputs, 10 relay outputs, and 8 analog outputs
• One BASyC™ system can control up to 4 valves in one or two separate temperature loops.
• Temperature control per ASSE 1017 during: power failure, outlet sensor failure, electric actuator or
thermostatic sensor failure and/or software/system reboot.
• Based on an MV17 control valve included as part of a Command Station or SFMMV Supply Fixture
assembly. If not ordered initially with BASyC™, Command Stations and SFMMV Supply Fixtures are
upgradeable to BASyC™ at a minimal cost.
• User-programmable sanitization with available email alarm includes “Safe Start” confirmation to minimize
the risks associated with high sanitization temperatures.
• BASyC’s open architecture allows for cost-effective customization. Any input or output not used for the
recirculation LTHW application can be assigned to monitor and activate or control 3rd party devices.
Contact Acorn for details and a price quotation.
• BASyC offers calculated flow and HW energy consumption data that’s accurate and reliable for identifying
user demand for flows ranging from 1 psid to the maximum pressure drop/flow.
• A flow sensor option gives BASyC™ the capability to provide the most accurate flow and energy data
at all user demand requirements.
• BASyC™ units are shipped with a standard 120vac/60hz cord/plug. The unit is capable of being
hardwired but this can be done after installation and start-up, thereby eliminating the need for
electrical coordination/timing.