BASyC

MODEL NO. ABMV

Optional User Interface

I N S T A L L A T I O N   &   M A I N T E N A N C E   G U I D E

DIGITAL MIXING VALVE

AND MONITORING SYSTEM

BASyC Operating Overview Screen

BASyC Control Panel

Belimo Acuator

Command Station  
upgraded with BASyC

Summary of Contents for BASyC ABMV

Page 1: ...ional User Interface I N S T A L L A T I O N M A I N T E N A N C E G U I D E DIGITAL MIXING VALVE AND MONITORING SYSTEM BASyC Operating Overview Screen BASyC Control Panel Belimo Acuator Command Stati...

Page 2: ...or whole building water systems Acorn is proud to continue its track record of providing valves while updating the product line with state of the art technology that keeps people safe Acorn Engineeri...

Page 3: ...ion Pump by Others 14 Inlet Temperature Sensor 14 Return Temperature Sensor 14 Pressure Sensor 15 Flow and Hot Water BTU Data 15 RECIRCULATION PUMP CONTROL 15 FLOW SENSOR 16 STARTUP 16 ADDING BASyC TO...

Page 4: ...s in one or two separate temperature loops Temperature control per ASSE 1017 during power failure outlet sensor failure electric actuator or thermostatic sensor failure and or software system reboot B...

Page 5: ...de kit and requires no change in plumbing piping or system operation Simply install the items included in the kit and your system is ready to go This is an exclusive benefit to purchasers of these sys...

Page 6: ...ired with 120vac 60hz power Disconnect power before servicing or doing any work within the control cabinet to prevent electrical shock and or equipment damage Make all connections in accordance with n...

Page 7: ...Inclusion and quantity varies by order CONTROL CABINET A Bypass Valve G Outlet Temperature Pressure Sensors H Test Port J MIXING VALVE B Electronic Actuator C Inlet HW temperature pressure sensors D I...

Page 8: ...djustment are the responsibility of the installer Optional pre configured units and or start up assistance are available please contact Acorn for details DISCONNECT LEAD THEN REVERSE Mixing Valve Hard...

Page 9: ...l component Install the upgrade bonnet noting the longer stem that s designed to accept the Belimo Actuator provided in the upgrade kit Electronic Actuator Installation Instructions Ensure that the ac...

Page 10: ...rovided mounted on a custom SS bracket and is shipped with the mounting hardware required to attach it to the strut framing The bottom of each control cabinet should be positioned so it is in line wit...

Page 11: ...on the configuration of your single or multi valve mixing assembly NETWORK COMMUNICATIONS Acorn BASyC includes several different types of network interfaces to ensure both versatility and adaptability...

Page 12: ...N CON TROLS ACORN CON TROLVALVES COM 1 8 0 0 4 8 8 8 9 9 9 12 Refer to this diagram for the model number of your BASyC system Available features will be explained on the following pages BASyC CONFIGUR...

Page 13: ...ACORN CON TROLS ACORN CON TROLVALVES COM 1 8 0 0 4 8 8 8 9 9 9 13...

Page 14: ...a high temp safety shutdown in the event that something goes wrong with the system We recommend setting this 10 degrees above the mixing station setpoint Relay Pump Control If equipped with this feat...

Page 15: ...flow or BTU values at the Operating Overview Screen and using the links that appear RECIRCULATION PUMP CONTROL If equipped with a recirculation pump option your BASyC Mixing Valve Assembly may have be...

Page 16: ...lush pipes of debris Open the isolation ball valves at the hot cold inlets the outlet and the return Look at T P gauges to make sure pressure is available at each Plug the Acorn BASyC unit into a stan...

Page 17: ...onds After all these LED s light as expected it will take another 5 10 minutes to boot load software and begin normal operation The first indicator of this is that the D1 LED will light up indicating...

Page 18: ...ld LCD display controller All units ship from the factory preset with a 4 digit LCD passcode of 0101 to access the system If your system is preconfigured please refer to your documentation or contact...

Page 19: ...1 Press to enter code and access unit After pressing enter you should see the screen above Navigate to the system settings and then TCP IP settings to see the following above Modify the values accord...

Page 20: ...b browser from any computer on this local area network If you re not sure how to ping a network do this 1 Open a cmd prompt Start Run cmd 2 Type in the command ping IP Address For example ping 10 1 10...

Page 21: ...shown in the icon name in case there is more than one BASyC system on the local area network The icons apps can be renamed to something more meaningful such as Building A HW You may want to keep the I...

Page 22: ...endix A has a list of items available based on the login credentials used The first time you log into each username the system will require a password reset Use passwords that are not easily guessed t...

Page 23: ...o click on the sensor data view button in the navigation menu shown above This button will take you to the screen shown below At each screen within the software you will see the navigation menu except...

Page 24: ...second loop if applicable Whenever you re servicing your actuator uncheck the box next to the actuator to disable it electronically The valve remains under thermostatic control at the current setpoint...

Page 25: ...number of degrees the temperature must drop below the setpoint before the pump is turned on again Dead band prevents relay chatter and fast cycling of the pump a condition that could result in a shor...

Page 26: ...TE Setting the maximum value below the minimum will trigger an alert and the indictor will change color from green in range to yellow out of range To enable an email alert you check the email checkbox...

Page 27: ...view in pdf Available user selections for are Time Range Today Last 24 hours Yesterday Week to Date Last week Last 7 days Month to Date Last Month Year to Date Last Year Title Give your report any na...

Page 28: ...on you aren t sure that all the fixtures served are not fully protected to insure the bather s safety during sanitization select cancel and restart sanitization after the proper safety precautions hav...

Page 29: ...nt of the outlet sensor all functionality will return OPERATING ACTUATOR MANUALLY To operate the Acorn BASyC electronic actuator manually 1 Make sure there is flow through the valve by opening fixture...

Page 30: ...oes below this value an alert will result 2 CW High Limit 35 to 200o F 130o F If the CW temp goes above this value an alert will result 2 HW Low Limit 35 to 200o F 110o F If the HW temp goes below thi...

Page 31: ...Fixture sensor will use that sensor for the pump control relay 5 Customization for Automatically Alternating Recirculation Pumps CONTACT ACORN FOR AVAILABILITY AND ADDITIONAL INFORMATION Pump Make an...

Page 32: ...ET PRESSURE 0 10 VDC 150 psi TRANSDUCER T4 3 T3 3 U11 GRND HW INLET PRESSURE 0 10 VDC 150 psi TRANSDUCER T4 4 T3 4 U10 GRND RETURN TEMP LOOP 1 0 5 VDC THERMISTOR 0V U9 CW INLET TEMPERATURE 0 5 VDC THE...

Page 33: ...d Acorn is notified in writing within one year from date of shipment F O B Industry California This warranty does not cover installation or labor charges and does not apply to materials which have bee...