background image

HY-PTK-120WPX20A

 

 
 

www.ACOPower.com

4120 Valley Blvd Walnut, CA 91789, USA

+1-626-737 1140

Power Your Green Life!

 

2.2 CHARGING STAGE-

The unit has a 6-stage charging algorithm.

Diagnose* - Soft Charge – Bulk Charge - Absorption charge – Equalizing Charge* - Float Mode 

Diagnose *

 – Only for Lithium battery type, subjected to the Lithium battery initial voltage then determinegoing to

Soft start or Bulk charge; if the Lithium battery is protected by BMS, the controller will automatically send the sign

al periodically to the battery terminal to activate the BMS against protection.

Soft start 

-

 

When batteries suffer an over-discharge, the controller will softly ramp the battery voltage upto 10V for

 12V battery, 20V for 24V battery.

Bulk Charge 

- Maximum current charging until batteries rise to Absorption level.

For Lead crystal battery type, the charge controller will deliver two step level of Bulk charge, when the first 

level rises the battery voltage up to14.4V, then switch into the second level of the 50% of the first bulk charge 

rate, until the Lead crystal battery voltage up to 14.7V. 

Absorption 

-

 

Constant voltage charging and battery is over 85% for lead acid battery; a Li-ion battery, LiFePO4

battery and LTO battery will close fully charging after absorption stage, the absorption voltage level will reach 12.6V 

for Li-ion battery, 14.4V for LiFePO4 battery; 14.0V for LTO battery. 14.7V for Lead crystal battery.

Equalization * 

Only for WET battery or Calcium battery type, when the battery is deeply drained below 10V or 

every 28 days cycle, it will automatically run this stage to bring the internal cells as an equal state and fully comp

lement the loss of capacity. (Lead crystal, Li-ion, LiFePO4, LTO, Gel and AGM battery do not run Equalization ch

arge)

Float Charge or Re-Bulk charge 

- Battery is fully charged and maintained at a safe level.A fully charged Lead 

acid battery (Crystal, GEL, AGM, WET battery) has a voltage of more than 13.8 Volts;if the lead acid battery volta

ge drops to 12.8V at float mode, it will return to Bulk charge; Li-ion,LiFePO4 and LTO battery have no float mode; 

If a Li-ion battery voltage drops to 12.0V after absorption stage, it willreturn to Bulk charge; if a LIFePO4 battery 

voltage drops to 13.4V, or LTO battery voltage drops to 13.2V after Absorption stage, they will return to Bulk 

charge. (voltage x 2 for 24V use)

Summary of Contents for HY-PTK-120WPX20A

Page 1: ...ve MC4 Cable 8 Junction box 9 Support fixing block 10 Solar panel 11 Hinge 12 Soft bag 13 Anderson Plug www ACOPower com HY PTK 120WPX20A 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 Summary of folding solar panel structure Notice When the bracket is folded to the extreme position please avoid using force to prevent the bracket from deforming A A position HX025 A 1000V HX025 B 1000V 2 1 10 ...

Page 2: ...ble with MC4 Connectors Max 240W Solar Panel needs adapter cables After receiving the solar panel kit please check if all accessories are included in the package and prepare to test your kit 1 Locate a sunlit area clear from hanging branches or obstacles 2 Unclip the two latches 2 Table 1 on the side of the unit and fold two panels outward Extend the two support legs 4 Table 1 to desired length an...

Page 3: ... will not power on with a bad battery A good thing to do is to test with your 12 V car battery Step 1 Clamp the red positive battery clip 5a Table1 to the positive terminal of 12V battery black negative battery clip 5b Table 1 to the negative terminal and make sure the connection is secure Step 2 When all the connections are complete the Battery status indicator 13 Figure 1 should light up if the ...

Page 4: ...re used as car battery RV battery boat battery and emergency back up battery Step 1 understand your battery battery type capacity and voltage Step 2 check the charge controller s set up We have defaulted the setting of the charge controller is for SEALED AGM is also included in SEALED type If your battery s type is different please set your battery type with the charge controller following the ins...

Page 5: ...tension Cable then connect the positive and negative MC4 of the controller to the MC4 Male Female Y Shape Branch output section MC4 Male Female Y Shape Branch is not included please purchase that if you need it Please see the connection diagram 4 Charge Your 24V battery Series 24V battery charging first connect two 120W PV modules in positive and negative connection to form a series system if the ...

Page 6: ...0 Power Your Green Life 5 RV Camper battery charging A If your RV Camper has a built in solar controller please refer to Figure 1 B If your RV Camper has no built in solar controller please refer to Figure 2 Note that please charge the battery please select the appropriate battery type ...

Page 7: ...ww ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 Power Your Green Life Figure 1 Figure 2 Please choose the right connector adapter Purchase separately Anderson Furrion Adapter Anderson Furrion Adapter ...

Page 8: ...Max Power Voltage Max Power Current Open Circuit Voltage Shortcircuit Current Module mm Kg W V A V A 2 60w 615 515 50 6 3 120 19 8 6 06 23 4 6 42 The ProteusX is ACOPOWER s first waterproof PWM charge controller It is a negative ground controller This ensure compatibility with any negative ground system which is the standard and most conventional way of grounding There are 8 Battery Type Compatibl...

Page 9: ...nting Figure 1 characteristic 2 Indicators Description and Operation 2 1 OPERATION LCD DISPLAY Please check your battery manufacturer s specifications to select correct battery type The unit provides eight 8 battery types for selections Lead crystal Lithium ion LiFePO4 LTO Gel AGM WET conventional lead acid and Calcium battery ...

Page 10: ...y LFP battery LTO battery shown in LCD indicates Lithium titianate oxidized Li4Ti5O12 battery Caution Incorrect battery type setting may damage your battery When the controller powers on the unit will run self qualify mode and automatically show below items on LCD before going into charging process Self test starts digital meter segments test Software version test Rated voltage and current test Ex...

Page 11: ...o 14 7V Absorption Constant voltage charging and battery is over 85 for lead acid battery a Li ion battery LiFePO4 battery and LTO battery will close fully charging after absorption stage the absorption voltage level will reach 12 6V for Li ion battery 14 4V for LiFePO4 battery 14 0V for LTO battery 14 7V for Lead crystal battery Equalization Only for WET battery or Calcium battery type when the b...

Page 12: ...t overvoltage protection a varistor or transient voltage suppressor TVS at the solar input and battery output against surge voltage Safety and EMC compliance IEC EN 60335 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 FCC Class B EN61000 4 6 EN61000 4 11 EN61000 3 3 CISPR14 1 4 MAINTENANCE Occasionally clean the case using a damp cloth and mild cleaning agent Check with terminals without loose ru...

Page 13: ... 0 2 VDC Gel type battery 14 1 0 2 VDC AGM type battery default setting 14 4 0 2 VDC WET type battery 14 7 0 2 VDC Calcium type battery 14 9 0 2 VDC LTO battery 14 0 0 2 VDC LFP battery 14 5 0 2 VDC Li ion battery 12 6 0 2 VDC 2 6 Absorption transits to Equalizing or Float condition Charging current drops to 1 5 0 1 AMP or Absorption charging timer timed out 4 Hour 2 7 Equalization charging active...

Page 14: ...re size 6 AWG stranded 16 mm2 5 3 Power terminal torque Up to 17 in lb 0 2n m 5 4 Mounting Vertical wall mounting 5 5 IP grade IP65 5 6 Net weight Approx 0 5KG 6 Environmental characteristics 6 1 Operating temperature 25 50 13 122 6 2 Storage temperature 40 85 40 185 6 3 Operating Humidity range 100 no condensation 6 Technical Specifications A There are 8 batteries can be used with it Lithium ion ...

Page 15: ...HY PTK 120WPX20A www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 Power Your Green Life ...

Page 16: ...HY PTK 120WPX20A www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 Power Your Green Life ...

Page 17: ... to 18 months Items can be replaced refurbished due to quality issues buyer pays for all shipping Charge Controller The controller itself comes with a 1 year warranty Within 30 days of purchase Items can be returned for a full refund or replacement we will cover return shipping due to quality issues buyer pays return shipping and replacement shipping due to non quality issues Within 30 days to 6 m...

Reviews: