Fixturlaser Laser Kit
S T E P 2
1.
Rough Alignment
• Vertical: Place scale or straightedge on highest hub
and
raise or lower the movable shaft to within 0,5 mm of the
stationary hub.
• Horizontal: Place scale or straightedge on hub nearest
to you and adjust the movable shaft to within 0,5 mm of
the stationary hub.
2.
Correct Obvious Soft Foot
Loosen all the bolts and find any obviously loose
shim
packs. Add shims as needed to make a snug fit.
3.
Follow Tightening Sequence
Follow the same sequence throughout the alignment pro-
cess, and tighten in 3 passes: snug first, 50% on second
pass, completely tight on the third pass (view sequence
on next page).