background image

number of short sound signals and will confirm the entry into a given programme by means of a short sound signal
modulated upward. At any moment we can interrupt the programming and exit the given programme by pressing push-
button [#] – the changes will not be saved then. 

The numbers of the respective programmes and the functions which they perform:
1_1

  – service activation of output 1 – causes activation of output 1 in accordance with the pre-set parameters in

programme 5 (time, beeper, generator). After completion of this programme, the automatic exit from the programming
function occurs. In order to call out the programme, select: [

key

][1507xxxx][11].

1_2

  – service activation of output 2 – causes activation of output 2 in accordance with the pre-set parameters in

programme 6 (time, beeper, generator). After completion of this programme, the automatic exit from the programming
function occurs. In order to call the programme, select: [

key

][1507xxxx][12].

2

 – Shift value setting (only in the mode of 255 codes). The function enables deduction or addition of shift value codes

from 1 to 998 to the code ordinal numbers, which will enable the selection of codes with ordinal numbers greater than
255 (the maximum number of codes does not change and still amounts to 255). For instance, for the negative shift
setting 500, we can select [502][[key]code No. 2 from Table of Codes] from the keypad. We can set (in programme
10), the positive or negative direction of shift, which enables the addition or deduction of the ordinal number of codes.
Owing to these settings, we can reproduce the codes and the method of their selection accurately, in the same way as
in ACO doorphone control units. In order to change the shift value, select:
[

key

][1507xxxx][2][shift value from 1 to 998] [

key

 (if this is a one- or two-digit value)].

3

 – the change in the 4-digit opening code. For instance, if we want to change code No. 9 to 4444, the following is

necessary: enter digit 3 (programme number) in the programming mode, the control unit will confirm the acceptance
with three short sound signals, and then digit 9 (code ordinal number ranging from 1 to 255), confirm with push-button
[key] and enter the new code value – 4444. If the shift is set, specify the code number together with the added shift. In
order to change the code, select [

key

][1507xxxx][3][code ordinal number 1-255] [

key

] [new 4-digit code].

4

 - selection of the lock operating mode – method of opening by means of a code.

-

Mode [0] – available 255 codes (before selection of the code, it is necessary to enter its ordinal number).

-

Mode [1-8] – available (depending on the entered value) from 1 to 8 codes selected directly without specifying
the code ordinal number. The respective codes correspond to the codes from the table of codes with ordinal
numbers 1, 2,…., 8. Upon entering the mode, the automatic exit from the programming function will take
place. In order to change the lock operating mode, select:
[

key

][1507xxxx][4][y], 

where [y] means the operating mode: y = [0] for the operating mode of 255 codes

  y = [number from 1 to 8] for the mode from 1 to 8 codes

NOTE!!!

If Output 2 is switched off (activity time equal to zero) 

all

 the codes switch on 

Output 1

If Output 2 is switched on (activity time other than zero), the codes with uneven ordinal numbers switch on

Output 1

, and those with even number switch on 

Output 2

5 – 

Output 1

 parameter setting 

The output parameters are entered as a three-digit number [xyz], where the respective digits mean:
x – [0 or 1] – activation / deactivation of the sound signal (beeper) during the output activity (0 – on, 1 – off),
y – [0 or 1] – method of shorting the output to ground (0 – pulse, 1 – permanently),
z – [number from 1 to 9] output activity time from 1 to 9 seconds (opening time e.g. electrical door strike)
For instance, if the setting of the electrical door strike opening time to 3s is required (pulse-controlled output), as the
sound signal is heard, enter number [003] in programme 5.
In order to change the parameters of Output 1, select [

key

][1507xxxx][5][xyz].

NOTE!!!
In order to control the electrical door strike, use the pulse control (y=0), and for relay control, use the permanent
control (y=1). 

6

 – 

Output 2

 parameter setting 

The setting is identical as for Output 1. 

Output 2

 is switched on, setting its activity time as other than zero.

7

  - a change in the installer code. In order to change the installer code: enter digit 7 (programme number) in the

programming mode, the control unit will confirm the acceptance by means of seven short sound signals, and then enter
four digits of the new code. After entering the last digit, the code will be saved and the exit from the programming
function will take place. The order of procedure: 
[

key

][1507xxxx][7][a new 4-digit installer code].

Reviews: