In the case of long connection lengths, the 
setting of the potentiometer may change due 
to the capacitive load of the electrode input. 
Therefore, it may be advisable to have the set-
ting checked after a change of cable length by 
a qualified contractor 

(notes on chapter 5)

.

General

 

Please read through the notes mentioned below and in the following chapters prior to commissioning! The symbols 
used in the manual are to point to safety risks.

 

The symbol used cannot replace the text of the safety note. Therefore, the text must always be read completely!

Symbol

Description

Texts with this symbol point to dangerous situations which could lead to 
death or severe injuries in case of non-observance of directions given. 
Texts with this symbol point to dangerous situations which could lead to 
light or severe injuries in case of non-observance of directions given.
Texts with this symbol point to situations which could cause faults during 
operation of the appliance in case of non-observance of directions given. 

The product may only be applied and operated 
in accordance with its intended use, as descri-
bed in this manual

 

(also refer to chapter 3.4)

.

The electrical connection must be carried out 
by a qualified contractor as per the pertinent 
VDE regulations.

The appliance may not be altered or subjected 
to other modifications.

•  The assembly or maintenance works may 

only be carried out by trained staff mem-
bers, authorised for this work thanks to their 
education.

•  Assembly and service works may only be 

carried out in dead-voltage condition.

The terminal can be damaged by incorrect 
bolting torques at the connecting terminals or 
by inappropriate tools by what insulation or 
contact making is jammed. Cables which were 
improperly connected can disconnect during 
operation and present a considerable safety 
risk. By transfer resistance at clamp connec-
tions, an increased heat build-up is generated 
which could cause a fire. Incorrectly wired con-
nections may damage electrical components 
and cause other damages 

(notes on chapter 5) 

.

Notes, safety notes and warnings

DANGER

CAUTION

NOTICE

DANGER

DANGER

DANGER

DANGER

DANGER

NOTICE

Summary of Contents for 3300.11.50

Page 1: ...tion I n s t a l l a t i o n a n d o p e r a t i n g m a n u a l GREASE LEVEL CONTROL Measuring device for grease layer thickness Please read through this manual carefully and completely prior to comm...

Page 2: ...4 1 Disassembly of appliance 5 4 2 Preparations at grease separator 6 4 3 Assembly of appliance in the grease separator 6 5 Commissioning 8 6 Operation 6 1 Function 9 6 2 Description of front wall of...

Page 3: ...ituations which could cause faults during operation of the appliance in case of non observance of directions given The product may only be applied and operated in accordance with its intended use as d...

Page 4: ...s are still flashing and when reaching 80 only 1 red LED is still lighting Emptying of the separator must be arranged Two relays with change over contact activate the aggregates signals The NC connect...

Page 5: ...rent use of the device is not permitted 4 1 Disassembly of appliance Step 2 Remove evaluation device and gripper clamps from measuring stick Step 1 Loosen spigot nut of angle plug and remove from meas...

Page 6: ...he grease separator With assembly opening Dismantle dummy plug with sealing and counter nut ACO grease separators are generally supplied with assembly opening for measuring device of grease layer thic...

Page 7: ...3 In the case of separators with high pressure HP internal cleaning fig A sensors 1 point towards HP Orbital cleaning head 2 and with separators without HP internal cleaning fig B towards a maintenan...

Page 8: ...must be carried out by an external fuse Observe operator protection Error current protective circuit Put the safety plug of the plug in evaluation device into the socket with earth contact mounted in...

Page 9: ...pacity Fuse protection of the load circuit must be car ried out externally via a fuse if required max 5A NC connection 2A NO connection For switching of higher currents relevant switching elements hav...

Page 10: ...r Evaluation at evaluation device Table C Half level signal 50 max grease storage cap Display Lights Sensors Water Grease off green red exists exists LED 4 LED 3 LED 2 LED 1 By pressing test button 1...

Page 11: ...s should be in the same position Only in the case of very different distances of electrodes to the reference electrode or in the case of long connection lines it is reasonable to adjust sensitivity in...

Page 12: ...feld Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 www aco haustechnik de www aco com ACO H a u s t e c h n i k Installation and Operating Manual As per 03 2010 Origin German Manual Art no 3300 11 50 HT...

Reviews: