XP-5R Beam
-
29
-
19 Channels mode1
:
Ch2
Ch1
Ch3
Ch4
Ch5
Pan
Tilt
Pan Fine
Tilt Fine
Function
P/T Macro speed
Ch6
Ch8
Ch7
0
0
255
540
0
0
255
270
19Channels(Mode1)
0
255
255
0
255
0
Slow
Fast
Pan/Tilt Speed
240-255 No Function
230-239 Lamp Off
220-229 Disable blackout while pan/tilt
gobo color change
210-219 Enable blackout while pan/tilt
gobo color change
200-209 Reset all
190-199 Frost/Focus/zoom reset
180-189 No function
170-179 Shutter/prism/R-Prism rest
160-169 Gobo reset
150-159 Color reset
140-149 Pan/tilt reset
130-139 Lamp on
120-129 Disable blackout while gobo change
110-119 Enable blackout while gogo change
100-109 Disable blackout while color change
90-99 Enable blackout while color change
80-89 Disable blackout while pan/tilt move
70-79 Enable blackout while pan/tilt move
60-69 Pan/tilt normal mode
50-59 Pan/tilt fast mode
40-49 Dimmer linear mode
30-39 Dimmer conventional mode
0-29 No Function
248-255 Macro31
240-247 Macro30
232-239 Macro29
224-231 Macro 28
216-223 Macro27
208-215 Macro26
200-207 Macro25
192-199 Macro24
184-191 Macro 23
176-183 Macro22
168-175 Macro21
160-167 Macro20
152-159 Macro19
144-151 Macro 18
136-143 Macro17
128-135 Macro16
120-127 Macro15
112-119 Macro14
104-111 Macro 13
096-103 Macro12
088-095 Macro11
080-087 Macro10
072-079 Macro9
064-071 Macro 8
056-063 Macro7
048-055 Macro6
040-047 Macro5
032-039 Macro4
024-031 Macro 3
016-023 Macro2
008-015 Macro1
000-007 Off
255
0
Slow
Fast
P/T Macro
10-
DANGER!
Install/change the gobo-wheel with the device switched off only.
5.2 Lamp
Philips MSD Platinum 5R (8000K)
y
Because of its high internal pressure, there might be a risk that the Discharge
lamp would explode during operation. The lamp emits intense UV radiation which
is harmful to the eyes and skin. The high luminance of the arc can cause severe
damage to the retina if you take a close look at the lamp.
y
To protect the lamp, always turn off the lamp first (via control panel or DMX
controller) and let the unit run at least five minutes to cool down before switching
off the mains supply. Never handle the lamp or luminary when it is hot.
y
Do not touch the bulb with bare hands. If this happens, clean the lamp with
denatured alcohol and wipe it with a lint free cloth before installation.
y
The lamp generates UV radiation. Never operate the lamp without appropriate
shielding.
y
When lighting up, the lamp operates at high pressure and there is a slight risk of arc
tube rupture. The risk increases with age, temperature and improper handling of the
lamp. Do not use the lamp longer than its lifespan.
y
Make sure the lamp is located in the center of the reflector for the best projection.
www.bluelight.at