background image

 
 

 

1.   Safety   Instructions       

 

 

WARNING

 

Please   keep   this   User   Manual   for   future   consultation.   If   you   sell   the   unit   to   another   user,   be   sure   

that   they   also   receive   this   instruction   booklet.   

 

Unpack   and   check   carefully   there   is   no   transportation   damage   before   using   the   unit.   

 

Before    operating,    ensure    that    the    voltage    and    frequency    of    power    supply    match    the    power   

requirements   of   the   unit.       

 

It’s   important   to   ground   the   yellow/green   conductor   to   earth   in   order   to   avoid   electric   shock.   

 

The   unit   is   for   indoor   use   only.   Use   only   in   a   dry   location.   

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   least   50cm   from   adjacent   

surfaces.   Be   sure   that   no   ventilation   slots   are   blocked.       

 

Disconnect   main   power   before   replacement   or   servicing.       

 

Make   sure   there   are   no   flammable   materials   close   to   the   unit   while   operating   as   it   is   fire   hazard.       

 

Use   safety   cables   when   installing   this   unit.   DO   NOT   handle   the   unit   by   taking   its   head   only,   but   

always   carry   by   its   base.           

 

Maximum   ambient   temperature   is   Ta:   40   degrees   C.   DO   NOT   operate   it   where   the   temperature   

is   higher   than   this.   

 

In   the   event   of   a   serious   operating   problem,   stop   using   the   unit   immediately.   Never   try   to   repair   

the   unit   by   yourself.   Repairs   carried   out   by   unskilled   people   can   lead   to   damage   or   malfunction.   

Please    contact    the    nearest    authorized    technical    assistance    center.    Always    use    the    same    type   

spare   parts.   

 

DO   NOT   touch   any   cables   during   operation   as   high   voltage   may   cause   electric   shock.   

Warning:   

 

To    prevent    or    reduce    the    risk    of    electrical    shock    or    fire,    do    not    expose    the    unit    to    rain    or   

moisture.   

 

The   housing   and   lenses   must   be   replaced   if   they   are   visibly   damaged.   

Please   read   carefully   the   instruction,   which   includes   important   information   
about   the   installation,   usage   and   maintenance.   

Summary of Contents for LED STROBE 50

Page 1: ...LED ST50 User Manual Please read the instruction carefully before use ...

Page 2: ... The Unit 4 3 1 Control panel 4 3 2 Main Functions 5 4 How To Control The Unit 9 4 1 Master Slave Built In Pre programmed Function 10 4 2 Easy Controller CA 8 10 4 3 DMX Controller 11 5 DMX 512 Configuration 11 6 DMX 512 Connection 14 7 Troubleshooting 14 8 Fixture Cleaning 15 ...

Page 3: ...materials close to the unit while operating as it is fire hazard Use safety cables when installing this unit DO NOT handle the unit by taking its head only but always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by ...

Page 4: ...ble that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed in a place where it is out of the reach of people and no one can pass by or under it 2 Technical Specifications 5 DMX Channel Modes 1 2 10 12 3 Operation modes DMX Master Slave mode Sound Activation Variable strobe speed and intensity Built in programs ...

Page 5: ...supply 3 POWER OUT Connect to supply power to the next fixture 4 DISPLAY To show the various menus and the selected functions BUTTON 5 MENU To select the programming functions 6 DOWN To go backward in the selected functions 7 UP To go forward in the selected functions 8 ENTER To confirm the selected functions LED 9 DMX On DMX input present 10 MASTER On Master Mode ...

Page 6: ... Stand by Function and Mode 17 DMX INPUT DMX 512 link use a 3 pin XLR cable to link the unit and DMX controller 18 DMX OUTPUT DMX 512 link use a 3 pin XLR cable to link to the next unit 3 2 Main Functions To select any of the given functions press the MENU button up to the required selection as shown on the display Select the function by pressing the ENTER button and the display will blink Use the...

Page 7: ...6 ...

Page 8: ...s and hold the MENU button for about one second or wait for one minute to exit the menu mode SLAVE MODE To select press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP buttons to select the SLAVE 1 SLAVE 2 modes Once the mode has been selected press the ENTER button to setup To go back to the functions without any changes press the MENU button again Press and hold the MENU b...

Page 9: ...without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode BLACKOUT MODE To select press the ENTER button to show BLACKOUT MODE on the display Use the DOWN UP buttons to select the blackout or normal mode Once the mode has been selected press the ENTER button to setup To go back to the functions without any chang...

Page 10: ... the functions without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode FIXTURE USE HOURS To select press the ENTER button to show the FIXTURE USE HOURS on the display and the display will show the number of working hours of the unit To go back to the functions without any changes press the MENU button again Pr...

Page 11: ... master mode and select random show or show 1 or or show 12 mode Any other units will have to be set in slave mode and select normal or 2 light show mode 2 light show In slave mode means the unit works normally and means 2 light show In order to create a great light show you can set on the second unit to get contrast movement to each other 4 2 Easy Controller CA 8 The CA 8 remote control is used o...

Page 12: ... will blink Use the DOWN UP buttons to change the DMX 512 address Once the address has been selected press and hold the ENTER button until the display stops blinking or it will store automatically after 7 seconds To go back to the functions without any changes press the MENU button again Please refer to the following diagram to address your DMX 512 channel for the first 4 units 5 DMX 512 Configura...

Page 13: ...12 3 Channels Mode ...

Page 14: ...13 10 Channels Mode 12 Channels Mode ...

Page 15: ...and input connectors are pass through type to maintain the DMX circuit when one of the units power is disconnected 3 Each fixture unit needs to have an address set to receive the data sent by the controller The address number is between 0 512 usually 0 1 are equal to 1 4 The end of the DMX 512 system should be terminated to reduce signal errors 7 Troubleshooting Following are a few common problems...

Page 16: ...ng Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the unit Set the correct address D No response to the sound 1 Make sure the unit is set into the correct mode 2 Check the microphone by tapping it 3 Make sure the fixture is not set into Blackout mode 8 Fixture Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency d...

Page 17: ...16 ...

Page 18: ...th the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 19: ...18 Innovation Quality Performance ...