background image

 
 

 

DMX 512 ADDRESS 

To select the 

, press the 

ENTER

 button to show the 

DMX ADDRESS

 on the display. Use the 

DOWN

/

UP

 button to adjust the address from 

1

 to 

512

. Once the address has been selected, press 

the

 ENTER

 button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press the 

MENU

 button for one second or wait for one minute to exit the 

menu mode. 

 

 

CHANNEL MODE

 

To select the 

, press the 

ENTER

 button to show the 

CHANNEL MODE

 on the display. Use the 

DOWN

/

UP

 button to select the 

1

2

10

12

 channel modes. Once the mode has been selected, 

press the 

ENTER

 button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press the 

MENU

 button for one second or wait for one minute to exit the 

menu mode. 

 

 

SLAVE MODE

 

To select the 

, press the 

ENTER

 button to show the 

SLAVE MODE

 on the display. Use the 

DOWN

/

UP

 button to select the 

  (

SLAVE 1)

  (

SLAVE 2)

 modes.

 

Once the mode has 

been selected, press the 

ENTER

 button to setup, to go back to the functions without any changes 

press the 

MENU 

button again. Hold and press the 

MENU

 button for one second or wait for one 

minute to exit the menu mode. 

 

 

SHOW MODE

 

To select the 

, press the 

ENTER

 button to show the 

SHOW MODE

 on the display. Use the 

DOWN

/

UP

 button to select the 

  (Random show), 

  (Show 1) or … or 

 

(Show 

12)

 

mode and 

  (

Manual show

)

.

 

Once the mode has been selected, press the 

ENTER

 button 

to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and 

press the 

MENU

 button for one second or wait for one minute to exit the menu mode. 

 

 

8A 

Summary of Contents for LED-ST50

Page 1: ...LED ST50 User Manual Please read the instruction carefully before use...

Page 2: ...The Unit 5 3 1 Control panel 5 3 2 Main Function 6 4 How To Control The Unit 11 4 1 Master Slave Built In Preprogrammed Function 11 4 2 Easy Controller 11 4 3 DMX Controller 12 5 DMX 512 Configuratio...

Page 3: ...close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature i...

Page 4: ...n the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to...

Page 5: ...justable by knobs Great built in lighting shows under Master Slave mode triggered by music Optional CA 8 for instant lighting shows Smooth 0 100 dimming and variable strobe speeds Ideal for pubs clubs...

Page 6: ...ed functions BUTTON 5 MENU To select the programming functions 6 DOWN To go backward in the selected functions 7 UP To go forward in the selected functions 8 ENTER To confirm the selected functions LE...

Page 7: ...of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the m...

Page 8: ...7A...

Page 9: ...Hold and press the MENU button for one second or wait for one minute to exit the menu mode SLAVE MODE To select the press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP button...

Page 10: ...s without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode BLACKOUT MODE To select the press the ENTER button to show...

Page 11: ...the unit To go back to the functions without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode FIXTURE HOURS To select...

Page 12: ...d light show This function is good when you want an instant show You have to set the first unit in master mode and select random show or show 1 or or show 12 mode Its DMX input jack will have nothing...

Page 13: ...X address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP...

Page 14: ...5 DMX 512 Configuration 1 2 Channels Mode 13A...

Page 15: ...10 Channels Mode 12 Channels Mode 14A...

Page 16: ...peed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintai...

Page 17: ...eck the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damag...

Page 18: ...on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass clean...

Page 19: ...he provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2...

Page 20: ...Innovation Quality Performance 19A...

Reviews: