background image

 
 

1. Safety Instructions   

 

 

 

WARNING

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 

that they also receive this instruction booklet. 

 

Unpack and check carefully there is no transportation damage before using the unit. 

 

Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

The unit is for indoor use only. Use only in a dry location. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 

surfaces. Be sure that no ventilation slots are blocked.   

 

Disconnect main power before replacement or servicing.   

 

Make sure there are no flammable materials close to the unit while operating as it is fire hazard.   

 

Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always 

by taking its base.     

 

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the temperature is higher 

than this. 

 

Unit surface temperature may reach up to 85

. DO NOT touch the housing bare-hand during its 

operation.  Turn off the power  and allow about 15 minutes  for the  unit  to cool down before 

replacing or serving. 

 

In the event of serious operating problem, stop using the unit immediately. Never try to repair 

the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. 

Please contact the nearest authorized technical assistance center. Always use the same type 

spare parts. 

 

DO NOT touch any wire during operation as high voltage might be causing electric shock. 

 

Please read carefully the instruction, which includes important information 
about the installation, usage and maintenance. 

 

2A 

Summary of Contents for LED-ST50

Page 1: ...LED ST50 User Manual Please read the instruction carefully before use...

Page 2: ...The Unit 5 3 1 Control panel 5 3 2 Main Function 6 4 How To Control The Unit 11 4 1 Master Slave Built In Preprogrammed Function 11 4 2 Easy Controller 11 4 3 DMX Controller 12 5 DMX 512 Configuratio...

Page 3: ...close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature i...

Page 4: ...n the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to...

Page 5: ...justable by knobs Great built in lighting shows under Master Slave mode triggered by music Optional CA 8 for instant lighting shows Smooth 0 100 dimming and variable strobe speeds Ideal for pubs clubs...

Page 6: ...ed functions BUTTON 5 MENU To select the programming functions 6 DOWN To go backward in the selected functions 7 UP To go forward in the selected functions 8 ENTER To confirm the selected functions LE...

Page 7: ...of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the m...

Page 8: ...7A...

Page 9: ...Hold and press the MENU button for one second or wait for one minute to exit the menu mode SLAVE MODE To select the press the ENTER button to show the SLAVE MODE on the display Use the DOWN UP button...

Page 10: ...s without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode BLACKOUT MODE To select the press the ENTER button to show...

Page 11: ...the unit To go back to the functions without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode FIXTURE HOURS To select...

Page 12: ...d light show This function is good when you want an instant show You have to set the first unit in master mode and select random show or show 1 or or show 12 mode Its DMX input jack will have nothing...

Page 13: ...X address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP...

Page 14: ...5 DMX 512 Configuration 1 2 Channels Mode 13A...

Page 15: ...10 Channels Mode 12 Channels Mode 14A...

Page 16: ...peed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintai...

Page 17: ...eck the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damag...

Page 18: ...on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass clean...

Page 19: ...he provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2...

Page 20: ...Innovation Quality Performance 19A...