030-039
040-049
050-059
060-069
070-079
080-089
090-099
100-109
110-119
120-139
140-149
150-159
160-199
200-209
210-219
220-229
230-255
Dimmer Curve Linear
Dimmer Curve Square Law
Dimmer Curve Inv SQ Law
Dimmer Curve S
No Function
No Function
No Function
Led Frequency Setting Enable
Led Frequency Setting Disable
No Function
Pan/Tilt Reset
Zoom Reset
No Function
All Reset
Dimmer Speed: Fast
Dimmer Speed: Smooth
No Function
6. Error Information
Error codes are shown continuously in the display when the fixture fails and they will not
disappear until the fixture is repaired.
1. CPU-B/C/D Error
Check whether the 485 (DATA) leads on the PCB board are installed in place or disconnected.
Check whether the related 485 (DATA) signal circuit on the PCB board is damaged.
2. Pan Reset Error
Check whether the position of the pan where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the pan operating range.
Check whether the Hall element on the pan is damaged.
Check whether the lead connecting the Hall element on the pan and the PCB board is in poor
contact or disconnected.
Check whether the motor on the pan is damaged.
Check whether the related circuit of the motor drive board on the pan is damage.
3. Pan Encode Error
Check whether the encoder on the pan is damaged.
Check whether the lead connecting the encoder on the pan and the PCB board is in poor contact
or disconnected.
55C