4. Tilt Reset Error
Check whether the position of the tilt where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the tilt operating range.
Check whether the Hall element on the tilt is damaged.
Check whether the lead connecting the Hall element on the tilt and the PCB board is in poor
contact or disconnected.
Check whether the motor on the tilt is damaged.
Check whether the related circuit of the motor drive board on the tilt is damage.
5. Tilt Encode Error
Check whether the encoder on the tilt is damaged.
Check whether the lead connecting the encoder on the tilt and the PCB board is in poor contact or
disconnected.
6. Zoom Reset Error
Check whether the position of the zoom where the magnet is installed falls off or is damaged.
Check whether there are obstacles in the zoom operating range.
Check whether the Hall element on the zoom is damaged.
Check whether the lead connecting the Hall element on the zoom and the PCB board is in poor
contact or disconnected.
Check whether the motor on the zoom is damaged.
Check whether the related circuit of the motor drive board on the zoom is damage.
7. LED Temp.1/2 Error
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board are damaged.
Check whether the lead on the temperature detecting board is installed in place or disconnected.
8. BaseFan1/2 Start Error
Check whether the fan is not running.
Check whether the fan leads are installed in place or disconnected.
Check whether the fan is damaged.
Check whether there are obstacles in the fan operating range.
9. BaseFan1/2 Stop Error
Check whether the fan circuit on the motherboard breaks down.
Check whether the component is damaged.
56C