1.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
DMX-output of the last unit.
2.
Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can
easily distort the signal and shut down the system.
3.
The DMX output and input connectors are pass-through to maintain the DMX circuit, when
power is disconnected to the unit.
4.
Each lighting unit needs to have an address set to receive the data sent by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
5.
The end of the DMX 512 system should be terminated to reduce signal errors.
6.
3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Pin 4/5: Not used.
7. Troubleshooting
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A.
The fixture does not work, no light
1.
Check the connection of power and main fuse.
2.
Measure the mains voltage on the main connector.
15B
Summary of Contents for Color Par 36
Page 1: ...User Manual Please read the instruc on carefully before use CP 36S ...
Page 7: ...6B ...
Page 18: ...17B ...