24. ArmFan5 Start Err 

Check if the fan is not running. 
Check if the fan leads are installed in place or disconnected. 
Check if the fan is damaged. 
Check if there are other interference items in the fan operating range. 

25. ArmFan5 Stop Err 

Check if the fan circuit on the motherboard breaks down. 
Check if the component is damaged. 

26. ArmFan5 Too Low 

Check if the fan is out of order. 
Check if there are other interference items in the fan operating range. 

27. ArmFan5 Too High 

Check if the fan is out of order. 
Check if the fan circuit on the motherboard breaks down. 

28. Lamp Hot Power Off 

Check if the temperature switch of the lamp is off. 
Check if the fans are still running properly. 

29. Gravity Sensor Error 

Check if the gravity sensor on board E is damaged. 

30. Lamp Maintenance 

Check lamp use time and replace the lamp in time. 

 
 
 
 
 
 
 
 
 
 
 

 

31G 

Summary of Contents for CETUS

Page 1: ......

Page 2: ...ht Source 7 4 3 Change The Lamp 8 4 4 Lamp Replacement Warning 10 5 How To Set The Unit 10 5 1 Main Function 10 5 2 Home Position Adjustment 18 6 Control By Universal DMX Controller 21 6 1 DMX512 Connection 21 6 2 Address Setting 22 6 3 DMX512 Configuration 22 7 Error Information 27 8 Troubleshooting 32 9 Fixture Cleaning 33 1G ...

Page 3: ...ise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 DO NOT connect the device to any dimmer pack During initial start up some smoke or smell may ar...

Page 4: ...ssistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials before transporting it again Hot lamp explosion hazard DO NOT open the unit within 15 minutes after switching off DO replace the bulb once it is damaged deformed or life expired DO NOT look directly at the light while the bulb is on Never touch bulb with b...

Page 5: ...solution 16 bit Dimmer Shutter Smooth dimming from 0 100 outstanding strobe effect with variable speed Color wheel 1 color wheel with 14 colors plus open and rainbow effect Gobo wheel 1 static gobo wheel with 16 gobos plus open Control DMX Channel 14 17 Channels Protocols DMX512 RDM Firmware Upgrade via DMX link Construction Display LCD Color display Data In Out 3 pin XLR Power In Out Power Connec...

Page 6: ...risms rotatable in both directions and overlayable Outstanding color macro effect Independent frost effect 2 fixed clamps for 50mm truss 2 pairs locking points of removable clamp for 70mm truss Dimension Weight 434x344x606mm 21 3kgs 17 1 x13 5 x23 9 in 47lbs 5G ...

Page 7: ...ter into move backward or leave the menu UP To go backward to move up in the menu DOWN To go forward to move down in the menu ENTER To perform the desired functions 3 BATTERY DISPLAY 4 DMX IN For DMX512 operation use 3 pin XLR cable to link the unit and DMX controller 5 DMX OUT For DMX512 operation use 3 pin XLR cable to link the next units 6G ...

Page 8: ... with the device switched off only Unplug from mains before changing the color wheel gobo wheels 4 2 Light Source OSRAM SIRIUS HRI 370W LL PHILIPS MSD Platinum 18 R LL Because of its high internal pressure there might be a risk that the Discharge lamp would explode during operation The lamp emits intense UV radiation which is harmful to the eyes and skin The high luminance of the arc can cause sev...

Page 9: ... 4 3 Change The Lamp Attention The entire light path and lens of the luminaire must be thoroughly cleaned before changing the bulb In the Work Mode the lamp life is 1500 hours when the Work Mode and the Sleep Mode are used alternately the lamp life is between 1500 and 6000 hours according to the ratio of lamp use time in the Sleep Mode the lamp life is 6000 hours Do not use the bulb beyond its lif...

Page 10: ... the lamp out of its recess disconnect the lamp and connect a new lamp that must be the same type with the old one And then place the new lamp into the lamp recess Finally reinstall the head cover fastening it securely before reapplying power Warning The installing direction of lamp 9G ...

Page 11: ...ssage Lamp Timeout Use Replace Lamp Now for up to 10 minutes After 10 minutes the fixture will return to normal operation Attention Damages caused by the failure to replace the bulb in time are not subject to warranty 5 How To Set The Unit 5 1 Main Function Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the monitor Select ...

Page 12: ...OSRAM SIRIUS HRI 370W LL 11G ...

Page 13: ...PHILIPS MSD Platinum 18 R LL 12G ...

Page 14: ...irm Use the UP DOWN button to select Blackout fixture blacks out if DMX signal stops or Hold fixture continues to obey the last command it received Via DMX if DMX signal stops press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode View DMX Value To select View DMX Value press the ENTER button to confirm Use the UP DOWN button t...

Page 15: ...utton to confirm Use the UP DOWN button to select On lamp on or Off lamp off press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode State Power On To select State Power On press the ENTER button to confirm Use the UP DOWN button to select On Lamp on while power on or Off Lamp off while power on press the ENTER button to store P...

Page 16: ...ER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Fixture Test To select Fixture Test press the ENTER button to confirm use the UP DOWN button to select Auto Test or Manual Test Auto Test Select Auto Test press the ENTER button to confirm the unit will run built in programs to automatically test pan tilt shutter color gobo prism prism ...

Page 17: ...let the unit idle 30 seconds to exit menu mode Lamp Time Reset Select Lamp Time Reset press the ENTER button to confirm use the UP DOWN button to set the password 050 press the ENTER button to reset lamp time Press the MENU button back to the last menu or exit menu mode idling 30 seconds Temperature Select Temperature press the ENTER button to confirm fixture temperature will show on the display p...

Page 18: ...to confirm use the UP DOWN button to select No normal or Yes the unit will run built in program to reset pan and tilt to their home positions press the ENTER button to store Press the MENU button to exit Effect Select Effect press the ENTER button to confirm use the UP DOWN button to select No or Yes the unit will run built in program to reset effect to their home positions press the ENTER button ...

Page 19: ... running time of the fixture Select the LAMP HOURS menu to display the running time of the lamp Select the LAMP STATE menu to turn on off the lamp Select the PAN INVERT menu and the fixture will run the pan invert mode Select the TILT INVERT menu and the fixture will run the tilt invert mode Select the RESET DEVICE menu the WARM RESET COLD RESET option will be displayed When WARM RESET is selected...

Page 20: ...e Select Shutter press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Color Enter offset mode Select Color press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 pres...

Page 21: ...on to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit R Prism 2 Enter offset mode Select R Prism 2 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Focus Enter offset mode Select Focus press the ENTER...

Page 22: ...signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 1 512 5 The end of the DMX...

Page 23: ...nit idle 30 seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 14 channels 1 15 29 43 17 channels 1 18 35 52 6 3 DMX512 Configuration Please refer to below configurations to control the fixtures Attentions 1 The unit will maintain the last condition until reset...

Page 24: ...17 019 020 022 023 025 026 028 029 031 032 034 035 037 038 040 041 043 044 046 047 049 050 052 053 055 056 127 128 189 190 193 194 255 GOBO White Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo 15 Gobo 16 Gobo shaking slow to fast Clockwise Rotation Fast to Slow Stop Counter Clockwise Rotation Slow to Fast 6 000 007 008 255 PRISM1 Close O...

Page 25: ...m Strobe Open 11 000 255 DIMMER 0 100 12 000 255 FOCUS 0 100 13 000 007 008 255 FROST Close Open 14 000 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 199 200 209 210 229 230 239 240 255 SPECIAL FUNCTION No Function Blackout While Pan Tilt Move Enable Blackout While Pan Tilt Move Disable Blackout While Color Move Enable Blackout While Color Move Disable Blackout Wh...

Page 26: ...6 059 060 127 128 189 190 193 194 255 COLOR White Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color 12 Color 13 Color 14 White to Color 14 Clockwise Rotation Fast to Slow Stop Counter Clockwise Rotation Slow to Fast 7 000 007 008 010 011 013 014 016 017 019 020 022 023 025 026 028 029 031 032 034 035 037 038 040 041 043 GOBO White Gobo 1 Gobo 2 Gobo 3 ...

Page 27: ...RISM 2 Close Open 11 000 127 128 189 190 193 194 255 R PRISM 2 0 100 Counter Clockwise rotation fast to slow Stop Clockwise rotation slow to fast 12 000 007 008 015 016 131 132 167 168 203 204 239 240 247 248 255 SHUTTER Close Open Strobe from slow to fast Fast close slow open Fast open slow close Pulsation from slow to fast Random Strobe Open 13 000 255 DIMMER 0 100 14 000 255 FOCUS 0 100 15 000 ...

Page 28: ... falls off or is damaged Check if there are other interference items in the pan operating range Check if the pan Hall elements is damaged Check if the pan Hall elements is in poor contact with the lead of the PCB board or disconnected Check if the pan motor is damaged Check if there is any damage to the circuit of the pan motor drive board 3 Pan Encode Error Check if the pan encoder is damaged Che...

Page 29: ...bo wheel operating range Check if the gobo wheel Hall elements is damaged Check if the gobo wheel Hall elements is in poor contact with the lead of the PCB board or disconnected Check if the gobo wheel motor is damaged Check if there is any damage to the circuit of the gobo wheel motor drive board 8 Focus Reset Error Check if the position of the focus mounting magnetic steel falls off or is damage...

Page 30: ...other interference items in the prism1 2 operating range Check if the prism1 2 Hall elements is damaged Check if the prism1 2 Hall elements is in poor contact with the lead of the PCB board or disconnected Check if the prism1 2 motor is damaged Check if there is any damage to the circuit of the prism1 2 motor drive board 12 BaseFan1 2 Start Err Check if the fan is not running Check if the fan lead...

Page 31: ... 2 4 Too High Check if the fan is out of order Check if the fan circuit on the motherboard breaks down 20 StrobeFan3 Start Err Check if the fan is not running Check if the fan leads are installed in place or disconnected Check if the fan is damaged Check if there are other interference items in the fan operating range 21 StrobeFan3 Stop Err Check if the fan circuit on the motherboard breaks down C...

Page 32: ...ent is damaged 26 ArmFan5 Too Low Check if the fan is out of order Check if there are other interference items in the fan operating range 27 ArmFan5 Too High Check if the fan is out of order Check if the fan circuit on the motherboard breaks down 28 Lamp Hot Power Off Check if the temperature switch of the lamp is off Check if the fans are still running properly 29 Gravity Sensor Error Check if th...

Page 33: ...hat may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED to see if it can be light up or not 32G ...

Page 34: ...e IC on the PCB might be out of condition D The lamp is cutting out intermittently 1 The lamp is not working well Check the mains voltage either too high or too low 2 Internal temperature may be too high Check if replacement of fan is needed on the head 9 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output C...

Page 35: ...ance with the provision of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 55032 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55035 2017 Harmonized Standard EN 60598 1 2015 A1 2018 EN 60598 2 17 2018 EN 62493 2015 Safety of household and similar electrical appliances Part 1 General requirements Part 2 Particular requirements 34G ...

Page 36: ...Innovation Quality Performance ...