4.
Connect the power supply
The product can take its power supply from one or two power sources (called
“Power1” and “Power2”) of 9 to 75 V DC, 7W min. Both sources come from
the same 5-ways M12 plug.
The product can also be powered from a POE injector (48 V DC) connected
to the “Lan2” plug.
Warning
: If you provide a POE power supply source,
do not
connect the 5-
way M12 power supply plug and cover it with the provided waterproof cap.
The device has no ON/OFF switch. It turns on automatically when power is
applied. Check the two Power1 and Power2 LEDs:
-
“Power1” is lit if POWER1 power supply or POE source is detected.
-
“Power2” is lit if POWER 2 power supply is detected.
The Diag led stays ON until the device is ready to use, usually in less than
10s.
5.
Connect the Ethernet cable
Plug the provided Ethernet cable to one of the Lan1 or Lan2 M12 connectors
of the device. Connect the RJ45 side to any RJ45 plug of the network, and
then check that either the “Lan1” or “Lan2” LED is ON (according to the
Ethernet port which is plugged in).
SOFTWARE CONFIGURATION
6.
Modifying the default IP address 192.168.1.253
The default configuration settings of the two Hyperlan-Pack systems have the
same IP address:
192.168.1.253
.
To access the web configuration pages of
the Hyperlan-Pack, the IP address of one of the two systems should be
changed the following way:
From any P.C. of the network, run the
ACKSYS NDM
multi-platform
application (found on the CD ROM).
Select the device and click on the «
Configure IP
» button.
You can configure the IP address or activate DHCP.
- 4 -