The access point controller must be powered
by a 12 V DC power supply and backed up by
a battery. The power terminals are polarized.
-
+
Alim
Auto protec-
tion
The A-P terminals follow the status of the mi-
croswitch positioned on the motherboard. Un-
der pressure the contact is normally closed.
Without pressure the contact is normally
open. This information can be returned to an
alarm center.
A-P
Reader
Connection
nº1
The reader can be powered by the + and -
Vout
terminals (12v DC - 500mA max).
The controller can receive the reader in
Wiegand or Clock & Data formats via the W0-
CK and W1-DT terminals.
Fresh out of the factory
:
The IN1 (PB1) input - C is dedicated to the
door control (relay 1) by pushbutton normally
open at idle.
The IN2 (G1) input - C is dedicated to the
supervision of the door by normally closed
magnetic contact.
The IN3 (I1) input - C is dedicated to read
enable by sensor normally open when it
is not in use. When the sensor switches to
the normally closed state, the reading is no
longer possible.
W1
DT
Vout
-
+
G1
IN2
I1
IN3
C
PB1
IN1
W0
CK
NO C NC NO C NC
NO C NC NO C NC
-
+
A-P
READER 1
BATTERY
DL1
PROGRAMMING
BRIDGE
N P
READER 2
RJ45
RJ45
RL4
RL3
RL2
RL1
W1
DT
Vout
-
+
G
IN2
I
IN3
C
PB
IN1
W0
CK
W1
DT
Vout
-
+
G
IN5
I
IN6
C
PB
IN4
W0
CK
Connectivity overview
Connection bounds description
ADIP Unity - Connection bounds description