Installation parameters
INSTALLER
25
ADIP
Installation Guide
System
description
Installation
parameters
Events
Accessories
Configuration
and cabling
Tables
Data
Compatible
elements
Functions
description
Delete
Supervision
Configuration of the 2 readers of the access point pag.1/4
Access point Reader 1:
Designation:
Indicate Designation
Input:
Output:
Free:
Active:
the reader works
Anti-Timeback:
00 mn.
time indicated in minutes, from 00 to 99
Access verification:
permission to access a second time, if the first one is not con-
sumed
Access point Reader 2:
Designation:
Indicate Designation
Input:
Output:
Free:
Active:
the reader works
Anti-Timeback:
00 mn
Access verification:
Exit with schedule control:
Do not select to allow to exit off-hours.
Do not forget to save the changes made with
Press
to advance to the next page
Input configuration pag.2/4
Input:
IN6
select inputs IN1 to IN6
Function:
select input function
Normally open
Normally closed
Designation of the function:
Do not forget to save the changes made with
Outputs configuration pag.2/4
Output:
RL4
select outputs RL1 to RL4
Configuration relay :
Timed -->
Temporisation relay:
Activation time from 1 to 240 seconds
Start/Stop
Follower
Function:
select output function
Timing function:
tempo of the selected output function
Function input:
Function Access point:
1
Function designation:
Access Point Configuration
Next page...