Operation
49
6.4.2
Specific Faults
The
Magic
Mark
marking software monitors the laser device for possible faults and pro-
vides the user with status messages about the state of individual system components.
The messages are displayed in the system windows
Messages
on the monitor.
Status/Error
Trigger
Message
Evaluation per Software
+/-15V Error,<13V >-13V
Head Control
ERROR 15V
D Cut Off
+/-15 Error,<13.5V >-13.5V
Head Control
WARNING 15V
Display Warning
Interlock circuits closed during the
starting process
Laser Safety Device
SD WARNING interlock
closed during startup
Display Warning
Interlock circuits open during
current labelling
Laser Safety Device
SD WARNING interlock
opened during operation
Display Warning
Shutter fault
Laser Safety Device
SD shutter ERROR
D Cut Off
Interlock fault
Laser Safety Device
SD interlock ERROR
D Cut Off
SD undervoltage
Laser Safety Device
SD ERROR internal
undervoltage
D Cut Off
SD error
Laser Safety Device
SD internal ERROR
D Cut Off
24V Error, <22.0V
LaserIFace
ERROR 24V
D Cut Off
24V Error, <22.5V
LaserIFace
WARNING 24V
Display Warning
Overload I/O
LaserIFace I/O
ERROR Overload I/O
D Cut Off
Laser fault
Laser beam source/
LaserIFace
ERROR Laser beam
source
D Cut Off
Temperature fault, Laser beam
source
Laser beam source/
LaserIFace
WARNING Temp > 40
deg.C
Display Warning