Chapter 4
98
Memory Test:
This message displays during a full memory test, counting
down the memory areas being tested.
Memory test fail
If POST detects an error during memory testing, additional
information appears giving specifics about the type and
location of the memory error.
Override enabled - Defaults loaded
If the system cannot boot using the current CMOS
configuration, the BIOS can override the current
configuration with a set of BIOS defaults designed for the
most stable, minimal-performance system operations.
Press TAB to show POST screen
System OEMs may replace the Phoenix Technologies
Award BIOS POST display with their own proprietary
display. Including this message in the OEM display permits
the operator to switch between the OEM display and the
default POST display.
Primary master hard disk fail
POST detects an error in the primary master IDE hard
drive.
Primary slave hard disk fail
POST detects an error in the secondary master IDE hard
drive.
Secondary master hard disk fail
POST detects an error in the primary slave IDE hard drive.
Secondary slave hard disk fail
POST detects an error in the secondary slave IDE hard
drive.
BIOS Messages
Action/FRU
Summary of Contents for Veriton 7600GTR
Page 6: ...VI ...
Page 9: ...IX Table of Contents ...
Page 76: ...Chapter 3 67 Veriton 5600GT V ...
Page 77: ...68 Chapter 3 Veriton 3600GT V ...
Page 98: ...Chapter 3 89 ...
Page 116: ...107 Chapter 5 ...
Page 119: ...Chapter 6 110 Veriton 5600GT 5600V Exploded Diagram ʳ ʳ ʳˆ ʳˇ ʳˈ ʳˉ ʳˊ ʳˋ ʳˌ ˆ ˇ ˈ ˉ ˊ ˋ ˌ ˆ ...
Page 129: ...Chapter 6 120 ...
Page 136: ...127 Appendix C ...