91                                                                     Altos R520 Installation Configuration Guide 

IOAT 

2.15 

EasyBUILD 8.0 build 200 (or later) 

Software Required 

The management utility of integrated SAS SW RAID can be found in the 
EasyBUILD. 

Software Version 

EasyBUILD 

Version 

RAID Web Console 

2.19-01 

EasyBUILD 8.0 build 100 (or later) 

Configuring integrated SAS hardware RAID 

Please refer to the Appendix B. for the integrated SAS SW RAID configuration.

 

Installation Tips 

NOTE. There is no built-in driver for Integrated SAS SW RAID in the Red Hat 
Enterprise Linux 5.0. You need an external USB floppy drive for applying driver 
during the OS installation.  

1. 

Since Red Hat Enterprise Linux 5.0 cannot recognize the integrated SAS 
SW RAID, you need to make a driver diskette from the EasyBUILD first 
before the installation. 

2. 

Type linux dd when the prompt boot: appears at the start. 

3. 

Please select the sda as the Driver Disk Source. 

4. 

Follow the instruction to load the integrated SAS hardware RAID driver 
from the driver diskette. 

5. 

At the package selection step, select Software Development for the 
installation package. 

6. 

Please follow the normal procedure to finish the installation. 

Gigabit Ethernet Driver Installation 

NOTE. Please install the 

kernel-devel-<version>

 package with the CD #1 of 

Red Hat Enterprise Linux 5 prior to install the Gigabit Ethernet driver. 

1.

 

You can find the Gigabit Ethernet driver in EasyBUILD. Please copy the 
driver from the EasyBUILD to HDD first. 

# mount /dev/dvd /mnt 

# cp –R /mnt/Disk/R520/NIC/Intel/pro1000.lx/. /tmp 

2.

 

Remove the OS built-in NIC driver 

# rmmod e1000.ko 

3.

 

Change the directory to the driver source and install the driver 

# cd /tmp/src/ 

# make install 

Summary of Contents for Network Device Altos R520

Page 1: ...dows Server 2008 Windows Server 2008 x64 Windows Server 2003 Windows Server 2003 x64 Windows 2000 Red Hat Enterprise Linux 4 0 32 bit 64 bit Red Hat Enterprise Linux 5 0 32 bit 64 bit SuSE Linux Enterprise Server 9 32 bit 64 bit SuSE Linux Enterprise Server 10 32 bit 64 bit NetWare 6 5 and VMware ESX Server 3 5 Version 1 4 December 2008 ...

Page 2: ... informational purposes only ACER MAKES NO WARRANTIES EXPRESS OR IMPLIED IN THIS DOCUMENT Acer Acer Altos are registered trademarks or trademarks of Acer Incorporation Other product or company names mentioned herein may be the trademarks of their respective owners ...

Page 3: ...nstallation 8 Gigabit Ethernet Driver Installation 8 IOAT Driver Installation 9 VGA Driver Installation 9 RAID Utility Installation 9 Network Utility Installation 9 Windows Server 2008 Enterprise x64 Edition Installation with integrated SAS hardware RAID 2 9 BIOS Required 9 Drivers Required 9 Software Required 10 Configuring integrated SAS hardware RAID 2 10 Installation Tips 10 Chipset Driver Ins...

Page 4: ... Network Utility Installation 18 Windows Server 2008 Enterprise Edition Installation with integrated SAS hardware RAID 18 BIOS Required 18 Drivers Required 18 Software Required 19 Configuring integrated SAS hardware RAID 19 Installation Tips 19 Chipset Driver Installation 20 Gigabit Ethernet Driver Installation 20 IOAT Driver Installation 20 VGA Driver Installation 21 RAID Utility Installation 21 ...

Page 5: ...tallation 29 Gigabit Ethernet Driver Installation 29 IOAT Driver Installation 29 VGA Driver Installation 30 RAID Utility Installation 30 Network Utility Installation 30 Windows Server 2003 Enterprise x64 Edition Installation with integrated SAS hardware RAID 30 Drivers Required 30 Software Required 30 Configuring integrated SAS hardware RAID 31 Installation Tips 31 Chipset Driver Installation 31 G...

Page 6: ...nstallation 41 RAID Utility Installation 41 Network Utility Installation 42 Windows Server 2003 Enterprise x64 Edition Installation with onboard SATA RAID 42 Drivers Required 42 Software Required 42 Configuring onboard SATA RAID 43 Installation Tips 43 Chipset Driver Installation 43 Gigabit Ethernet Driver Installation 44 IOAT Driver Installation 44 VGA Driver Installation 44 Microsoft Scalable Ne...

Page 7: ...AS SW RAID 53 Drivers Required 53 Software Required 54 Configuring integrated SAS SW RAID 54 Installation Tips 54 Chipset Driver Installation 54 Gigabit Ethernet Driver Installation 55 IOAT Driver Installation 56 VGA Driver Installation 56 Microsoft Scalable Networking Pack Installation 56 RAID Utility Installation 56 Network Utility Installation 57 Windows Server 2003 Enterprise Edition SP1 Insta...

Page 8: ...Driver Installation 66 VGA Driver Installation 67 RAID Utility Installation 67 Network Utility Installation 67 Windows 2000 Advanced Server SP4 Installation with integrated SAS SW RAID 67 Drivers Required 68 Software Required 68 Configuring integrated SAS SW RAID 68 Installation Tips 68 Chipset Driver Installation 68 Gigabit Ethernet Driver Installation 69 IOAT Driver Installation 69 VGA Driver In...

Page 9: ... RAID 79 Drivers Required 79 Software Required 79 Configuring integrated SAS hardware RAID 80 Installation Tips 80 Gigabit Ethernet Driver Installation 80 IOAT driver installation 81 RAID Utility Installation 81 Red Hat Enterprise Linux 5 0 EM64T Installation with Onboard SATA RAID 82 Drivers Required 82 Software Required 82 Configuring integrated SAS hardware RAID 82 Installation Tips 82 Gigabit ...

Page 10: ...Ethernet Driver Installation 94 IOAT driver installation 95 RAID Utility Installation 95 Red Hat Enterprise Linux 4 0 EM64T Update 3 Installation with integrated SAS hardware RAID 96 Drivers Required 96 Software Required 96 Configuring integrated SAS hardware RAID 96 Installation Tips 96 Gigabit Ethernet Driver Installation 97 RAID Utility Installation 97 Red Hat Enterprise Linux 4 0 EM64T Update ...

Page 11: ...equired 106 Software Required 106 Configuring integrated SAS hardware RAID 2 106 Installation Tips 106 Gigabit Ethernet Driver Installation 107 RAID Utility Installation 107 Red Hat Enterprise Linux 4 0 Update 3 Installation with integrated SAS SW RAID 108 Drivers Required 108 Software Required 108 Configuring integrated SAS SW RAID 108 Installation Tips 108 Gigabit Ethernet Driver Installation 10...

Page 12: ... installation 121 RAID Utility Installation 121 SUSE Linux Enterprise Server 10 EM64T Installation with onboard SATA RAID 122 Drivers Required 122 Software Required 122 Configuring onboard SATA RAID 122 Installation Tips 123 Gigabit Ethernet Driver Installation 124 IOAT driver installation 124 RAID Utility Installation 125 SUSE Linux Enterprise Server 9 EM64T Service Pack 3 Installation with integ...

Page 13: ...re Required 134 Configuring integrated SAS hardware RAID 134 Installation Tips 134 Gigabit Ethernet Driver Installation 136 IOAT driver installation 136 RAID Utility Installation 137 SUSE Linux Enterprise Server 10 Installation with integrated SAS hardware RAID 2 137 Drivers Required 137 Software Required 138 Configuring integrated SAS hardware RAID 2 138 Installation Tips 138 Gigabit Ethernet Dri...

Page 14: ...lation 151 SUSE Linux Enterprise Server 9 Service Pack 3 Installation with integrated SAS SW RAID 152 Drivers Required 152 Software Required 152 Configuring integrated SAS SW RAID 152 Installation Tips 152 Gigabit Ethernet Driver Installation 153 RAID Utility Installation 153 SUSE Linux Enterprise Server 9 Service Pack 3 Installation with onboard SATA RAID 154 Drivers Required 154 Software Require...

Page 15: ...e integrated SAS SW RAID Configuration Utility 165 Loading integrated SAS SW RAID default setting 165 Create RAID 1 volume 165 Initial RAID Volume 166 Save and Exit Embedded RAID II Configuration Utility 166 APPENDIX C ONBOARD SATA RAID CREATION 167 Configuring the onboard SATA RAID 167 Load BIOS default setting 167 Enable onboard SATA RAID function 167 Enter the onboard SATA RAID Configuration Ut...

Page 16: ......

Page 17: ...you a briefly and quick hardware information about Altos R520 The operating system installation tips Where Can I Download the Latest Altos R520 Installation Configuration Guide The Altos R520 Installation Configuration Guide would be updated on a monthly basis Please download the latest release from the Acer Support web site INTRODUCTION ...

Page 18: ...B 2GB FB DIMM 533 or FB DIMM 667 Maximum memory of 32GB when 4GB DIMM is available Up to 17 GB s maximum b w for FB DIMM 533 Up to 21 GB s maximum b w for FB DIMM 677 Support memory sparing and memory mirroring Storage Interface LSI SAS 1068 1078 3Gb s SAS controller Six SATA ports One ATA 100 port Expansion Slots Total 2 slots one full height slot one low profile slot Low profile riser slot One x...

Page 19: ... O Acceleration Technology BMC BMC Baseboard Management Controller IPMI 2 0 compliant Option Can be upgraded to Intel Remote Management Module with Virtual Media and remote KVM support Availability sub system System Power Supply 1 1 redundant 650W power supply Hot Swap Storage Subsystem Drive Bays Six front accessible drive bay for 2 5 SAS SATA HDD Optional front accessible bay space for 7th 8th H...

Page 20: ...Altos R520 Installation Configuration Guide 4 System Block Diagram BOARD LAYOUT ...

Page 21: ... 512 MB 1 GB 512 MB 2 512 MB Sparing 512 MB 512 MB Sparing 512 MB 2 GB 1 GB 3 512 MB Sparing 512 MB 512 MB Sparing 512 MB 512 MB Sparing 512 MB 512 MB Sparing 512 MB 4 GB 2 GB 4 1 GB Sparing 1 GB 2 GB 1 GB 5 1 GB Sparing 1 GB 1 GB Sparing 1 GB 4 GB 2 GB 6 1 GB Sparing 1 GB 1 GB Sparing 1 GB 1 GB Sparing 1 GB 1 GB Sparing 1 GB 8 GB 4 GB 7 2 GB Sparing 2 GB 4 GB 2 GB 8 2 GB Sparing 2 GB 2 GB Sparing...

Page 22: ...erprise Server 10 EM64T n a Certified NetWare 6 5 SP5 Certified NOTE1 Altos R520 BIOS P88 or later BMC 63 or later and FRUSDR 47 or later are required to support Windows Server 2008 NOTE2 This Windows Server 2008 certification also applies to Standard Edition and Web Server 2008 NOTE3 EasyBUILD 8 0 build 200 or later can support Windows Server 2008 The drivers required for the OS installation can ...

Page 23: ...ter Onboard VGA 8 240 50 3000 EasyBUILD 8 0 build 200 or later Onboard USB 2 0 N A OS built in IOAT 1 2 79 9 EasyBUILD 8 0 build 200 or later Hot swap backplane N A OS built in Software Required The management utility of integrated SAS hardware RAID and NIC can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 2 63 EasyBUILD 8 0 build 200 or later Intel PROSet Utility...

Page 24: ...tes you would see the following devices with yellow mark in Device Manager Chipset Driver Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Drivers Altos R520 Chipset select Windows Server 2008 x64 and click on Setup 3 Follow the instruction to install the driver and reboot the server after the chipset driver is installed Gigabit Ethernet Driver Installation 1 There is bui...

Page 25: ...ect Windows Server 2008 x64 and click on Setup 3 Follow the instruction to install the VGA driver and reboot the server after the driver is installed RAID Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Integrated SAS hardware RAID select RAID Web Console 2 Windows and click on Setup 3 Follow the instruction and use the default setting to com...

Page 26: ...D 8 0 build 200 or later Configuring integrated SAS hardware RAID 2 Please refer to the APPENDIX D for the integrated SAS hardware RAID 2 configuration Installation Tips NOTE The Windows Server 2008 x64 can recognize integrated SAS hardware RAID 2 Please replace the driver with the one provided by EasyBUILD You need an external USB floppy drive or USB Flash drive to load driver during the OS insta...

Page 27: ...r with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 x64 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Install...

Page 28: ...lation The PROSet utility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise x64 Edition Installation with integrated SAS SW RAID Below information describes how to manually install Windows Server 2008 Enterprise x64 Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63...

Page 29: ... driver of Integrated SAS SW RAID in the Windows Server 2008 x64 You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel Embedded Server RAID Technology II A MegaSR inf as target...

Page 30: ...r with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 x64 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Install...

Page 31: ...llation The PROSet utility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise x64 Edition Installation with onboard SATA RAID Below information describes how to manually install Windows Server 2008 Enterprise x64 Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63 or ...

Page 32: ...of Onboard SATA RAID in the Windows Server 2008 x64 You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel Embedded Server RAID Technology II A MegaSR inf as target driver 4 Aft...

Page 33: ...r with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 x64 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Install...

Page 34: ...lity for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise Edition Installation with integrated SAS hardware RAID Below information describes how to manually install Windows Server 2008 Enterprise Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63 or later and FRUSDR 47...

Page 35: ...integrated SAS hardware RAID Please replace the driver with the one provided by EasyBUILD You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel R RAID Controller SROMBSAS18E A ...

Page 36: ...with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation ...

Page 37: ...tility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise Edition Installation with integrated SAS hardware RAID 2 Below information describes how to manually install Windows Server 2008 Enterprise Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63 or later and FRUSD...

Page 38: ...e integrated SAS hardware RAID 2 Please replace the driver with the one provided by EasyBUILD You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel R RAID Controller SROMBSASMP...

Page 39: ...with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation ...

Page 40: ...stallation The PROSet utility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise Edition Installation with integrated SAS SW RAID Below information describes how to manually install Windows Server 2008 Enterprise Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63 or ...

Page 41: ... of Integrated SAS SW RAID in the Windows Server 2008 x64 You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel Embedded Server RAID Technology II A MegaSR inf as target driver...

Page 42: ...with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation ...

Page 43: ...nstallation The PROSet utility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2008 Enterprise Edition Installation with onboard SATA RAID Below information describes how to manually install Windows Server 2008 Enterprise Edition on Altos R520 BIOS Required Altos R520 BIOS P88 or later BMC 63 or late...

Page 44: ... onboard SATA RAID in the Windows Server 2008 You need an external USB floppy drive or USB Flash drive to load driver during the OS installation 1 Please make a driver diskette from the EasyBUILD first before the installation 2 Click on Load Driver when Where do you want to install Windows message displayed 3 Select Intel Embedded Server RAID Technology II A MegaSR inf as target driver 4 After loa...

Page 45: ...with EasyBUILD Please do the same on both of the devices 2 Please insert the EasyBUILD into the optical drive 3 Expand Drivers Altos R520 Network adapters Intel 82563EB Gigabit Ethernet Controller select Windows Server 2008 and click on Setup 4 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation ...

Page 46: ...utility for the onboard Gigabit Ethernet controller will be installed automatically when you installing the onboard Gigabit Ethernet driver Windows Server 2003 Enterprise x64 Edition Installation with integrated SAS hardware RAID Below information describes how to manually install Windows Server 2003 Enterprise x64 Edition on Altos R520 Drivers Required For Windows Server 2003 x64 Installation the...

Page 47: ...driver of Integrated SAS hardware RAID in the Windows Server 2003 x64 You need an external USB floppy drive to load driver during the OS installation 1 As Windows Server 2003 x64 can t recognize the integrated SAS hardware RAID you need to make a driver diskette from the EasyBUILD first before the installation 2 Press F6 at the beginning of installation for providing the driver diskette for the in...

Page 48: ...abit Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in the se...

Page 49: ...under Other device in Windows Device Manager It is the hot swap SAS backplane for R520 2 Right click on the ESG SHV SCA HSBP M11 SCSI Enclosure Device and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in th...

Page 50: ...ick on Setup 3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gigabit Ethernet Controller Intel PRO 1000 Network Adapter select PROSet Utility Windows Server 2003 x64 and click on Setup 3 Follow the instruction and use the default setti...

Page 51: ...egrated SAS hardware RAID 2 Please refer to the APPENDIX D for the integrated SAS hardware RAID 2 configuration Installation Tips NOTE There is no built in driver of Integrated SAS hardware RAID 2 in the Windows Server 2003 x64 You need an external USB floppy drive to load driver during the OS installation 1 As Windows Server 2003 x64 can t recognize the integrated SAS hardware RAID 2 you need to ...

Page 52: ...abit Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in the se...

Page 53: ...under Other device in Windows Device Manager It is the hot swap SAS backplane for R520 2 Right click on the ESG SHV SCA HSBP M11 SCSI Enclosure Device and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in th...

Page 54: ... and click on Setup 3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gigabit Ethernet Controller Intel PRO 1000 Network Adapter select PROSet Utility Windows Server 2003 x64 and click on Setup 3 Follow the instruction and use the defaul...

Page 55: ... refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE There is no built in driver of Integrated SAS SW RAID in the Windows Server 2003 x64 You need an external USB floppy drive to load driver during the OS installation 1 As Windows Server 2003 x64 can t recognize the integrated SAS SW RAID you need to make a driver diskette from the EasyBUILD first before the...

Page 56: ... the onboard Intel 82563EB Gigabit Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check I...

Page 57: ...ation 1 Windows will treat onboard VGA as Standard VGA device You can find the ATI ES1000 driver in EasyBUILD Please insert the EasyBUILD into the optical drive 2 Expand Drivers Altos R520 Graphics adapters ATI ES1000 select Windows Server 2003 x64 and click on Setup 3 Follow the instruction to install the VGA driver and reboot the server after the driver is installed 4 After installing the driver...

Page 58: ... Windows Server 2003 Enterprise x64 Edition on Altos R520 Drivers Required For Windows Server 2003 x64 Installation the following device drivers are required Device Version EasyBUILD Version onboard SATA RAID 04 24 0620 20 06 EasyBUILD 7 1 build 400 or later Onboard Chipset 7 4 0 1005 EasyBUILD 7 1 build 400 or later Onboard Gigabit Ethernet 9 3 39 EasyBUILD 7 1 build 400 or later Onboard VGA 8 24...

Page 59: ...nboard SATA RAID you need to make a driver diskette from the EasyBUILD first before the installation 2 Press F6 at the beginning of installation for providing the driver diskette for the onboard SATA RAID 3 Select Intel Embedded Server RAID Technology II Windows XP 2003 64 bit as target driver 4 After loading the RAID driver from diskette follow the normal procedure to finish the installation Chip...

Page 60: ... driver 7 Click on Next and follow the instruction to finish the driver update 8 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation 1 For Base System Device it should be the onboard IOAT device You could find the driver in EasyBUILD 2 Right click on the Base System Device and select Update Drive...

Page 61: ...lled RAID Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Onboard SATA RAID select RAID Web Console 2 Windows and click on Setup 3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gi...

Page 62: ...t Utility 10 4 4 2 EasyBUILD 7 1 build 400 or later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE There is no built in driver of Integrated SAS hardware RAID in the Windows Server 2003 You need an external USB floppy drive to load driver during the OS installation 4 As Windows Server 2003 can t reco...

Page 63: ...it Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in the sear...

Page 64: ...d under Other device in Windows Device Manager It is the hot swap SAS backplane for R520 2 Right click on the ESG SHV SCA HSBP M11 SCSI Enclosure Device and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in ...

Page 65: ...ck on Setup 3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gigabit Ethernet Controller Intel PRO 1000 Network Adapter select PROSet Utility Windows Server 2003 and click on Setup 3 Follow the instruction and use the default setting to...

Page 66: ...tegrated SAS hardware RAID 2 Please refer to the APPENDIX D for the integrated SAS hardware RAID 2 configuration Installation Tips NOTE There is no built in driver of Integrated SAS hardware RAID 2 in the Windows Server 2003 You need an external USB floppy drive to load driver during the OS installation 1 As Windows Server 2003 can t recognize the integrated SAS hardware RAID 2 you need to make a ...

Page 67: ...it Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in the sear...

Page 68: ...d under Other device in Windows Device Manager It is the hot swap SAS backplane for R520 2 Right click on the ESG SHV SCA HSBP M11 SCSI Enclosure Device and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in ...

Page 69: ...d click on Setup 3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gigabit Ethernet Controller Intel PRO 1000 Network Adapter select PROSet Utility Windows Server 2003 and click on Setup 3 Follow the instruction and use the default setti...

Page 70: ...refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE There is no built in driver of Integrated SAS SW RAID in the Windows Server 2003 You need an external USB floppy drive for applying driver during the OS installation 1 As Windows Server 2003 can t recognize the integrated SAS SW RAID you need to make a driver diskette from the EasyBUILD first before the ins...

Page 71: ...it Ethernet controller You could find the driver in EasyBUILD Please do the same on both of the devices 2 Right click on the Ethernet Controller and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check Include this location in the sear...

Page 72: ...ATI ES1000 driver in EasyBUILD Please insert the EasyBUILD into the optical drive 2 Expand Drivers Altos R520 Graphics adapters ATI ES1000 select Windows Server 2003 and click on Setup 3 Follow the instruction to install the VGA driver and reboot the server after the driver is installed 4 After installing the driver you would see ATI ES1000 listed in Display adapters Microsoft Scalable Networking ...

Page 73: ...allation the following device drivers are required Device Version EasyBUILD Version onboard SATA RAID 04 24 0620 20 06 EasyBUILD 7 1 build 400 or later Onboard Chipset 7 4 0 1005 EasyBUILD 7 1 build 400 or later Onboard Gigabit Ethernet 9 3 39 0 EasyBUILD 7 1 build 400 or later Onboard VGA 8 24 3 0 EasyBUILD 7 1 build 400 or later Onboard USB 2 0 N A OS built in IOAT 1 2 52 0 EasyBUILD 7 1 build 4...

Page 74: ... to provide the driver disk for the onboard SATA RAID 3 Select Intel Embedded Server RAID Technology II Windows XP 2003 as target driver 4 After loading the RAID driver from diskette follow the normal procedure to finish the installation Chipset Driver Installation 1 After the installation completes you would see the following devices with yellow mark in Device Manager 2 Please insert the EasyBUIL...

Page 75: ...rk adapters IOAT Driver Installation 1 For Base System Device it should be the onboard IOAT device You could find the driver in EasyBUILD 2 Right click on the Base System Device and select Update Driver 3 Select No not this time Do not connect to Windows Update to search the driver 4 Select Install from a list or specific location Advanced 5 Select Search the best driver these locations and check ...

Page 76: ...3 Follow the instruction and use the default setting to complete the RAID Utility Installation Network Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Intel Gigabit Ethernet Controller Intel PRO 1000 Network Adapter select PROSet Utility Windows Server 2003 and click on Setup 3 Follow the instruction and use the default setting to complete th...

Page 77: ... for the integrated SAS hardware RAID configuration Installation Tips NOTE There is no built in driver Integrated SAS hardware RAID in the Windows Server 2003 You need an external USB floppy drive to load driver during the OS installation 1 As Windows 2000 can t recognize the integrated SAS hardware RAID you need to make a driver diskette from the EasyBUILD first before the installation 2 Press F6...

Page 78: ...nboard Intel 82563EB Gigabit Ethernet controller You could find the driver in EasyBUILD Please do the same on the both of the devices 2 Right click on the Ethernet Controller and select Properties 3 Select Driver tab and click on Update Driver 4 Follow the instructions Select Search for a suitable driver for my device Recommended and click on Next 5 Check on the Specify a location and click on Nex...

Page 79: ...ager It is the hot swap SAS backplane for R520 2 Right click on the ESG SHV SCA HSBP M11 SCSI Enclosure Device and select Properties 3 Select Driver tab and click on Update Driver 4 Follow the instructions Select Search for a suitable driver for my device Recommended and click on Next 5 Check on the Specify a location and click on Next to specify the path for the driver 6 Follow the instruction to...

Page 80: ... integrated SAS hardware RAID 2 Below information describes how to manually install Microsoft Windows 2000 Advanced Server SP4 on Altos R520 with integrated SAS hardware RAID 2 Drivers Required For Windows 2000 Installation the following device drivers are required Device Version EasyBUILD Version Integrated SAS hardware RAID 2 2 20 0 32 EasyBUILD 8 0 build 200 or later Onboard Chipset 8 3 0 1011 ...

Page 81: ...e to load driver during the OS installation 1 As Windows 2000 can t recognize the integrated SAS hardware RAID 2 you need to make a driver diskette from the EasyBUILD first before the installation 2 Press F6 at the start of installation to provide the driver disk for the onboard ROMB 3 Select Intel R SAS RAID Controller Driver Windows 2000 as target driver 4 After loading the driver from diskette ...

Page 82: ...river 6 Follow the instructions to finish the installation 7 After installing the driver you would see Intel R PRO 1000 EB Network Connection with I O Acceleration listed in Network adapters IOAT Driver Installation 1 For Base System Device it should be the onboard IOAT device You could find the driver in Resource CD 2 Right click on the Base System Device and select Properties 3 Select Driver tab...

Page 83: ...Follow the instruction to install the VGA driver and reboot the server after the driver is installed 5 After installing the driver you would see ATI ES1000 listed in Display adapters RAID Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Integrated SAS Hareware RAID select RAID Web Console 2 Windows and click on Setup 3 Follow the instruction a...

Page 84: ...BUILD 7 1 build 400 or later Intel PROSet Utility 10 4 4 2 EasyBUILD 7 1 build 400 or later Configuring integrated SAS SW RAID Please refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE There is no built in driver Integrated SAS SW RAID in the Windows Server 2003 You need an external USB floppy drive to load driver during the OS installation 1 As Windows 200...

Page 85: ...the driver in EasyBUILD Please do the same on the both of the devices 2 Right click on the Ethernet Controller and select Properties 3 Select Driver tab and click on Update Driver 4 Follow the instructions Select Search for a suitable driver for my device Recommended and click on Next 5 Check on the Specify a location and click on Next to specify the path for the driver 6 Follow the instructions t...

Page 86: ...000 and double click on Windows 2000 4 Follow the instruction to install the VGA driver and reboot the server after the driver is installed 5 After installing the driver you would see ATI ES1000 listed in Display adapters RAID Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Integrated SAS SW RAID select RAID Web Console 2 Windows and click on...

Page 87: ...asyBUILD 7 1 build 400 or later Intel PROSet Utility 10 4 4 2 EasyBUILD 7 1 build 400 or later Configuring onboard SATA RAID Please refer to the Appendix C for the onboard SATA RAID configuration Installation Tips NOTE There is no built in driver Onboard SATA RAID in the Windows Server 2003 You need an external USB floppy drive to load driver during the OS installation 1 As Windows 2000 can t reco...

Page 88: ...the driver in EasyBUILD Please do the same on the both of the devices 2 Right click on the Ethernet Controller and select Properties 3 Select Driver tab and click on Update Driver 4 Follow the instructions Select Search for a suitable driver for my device Recommended and click on Next 5 Check on the Specify a location and click on Next to specify the path for the driver 6 Follow the instructions t...

Page 89: ...nd double click on Windows 2000 4 Follow the instruction to install the VGA driver and reboot the server after the driver is installed 5 After installing the driver you would see ATI ES1000 listed in Display adapters RAID Utility Installation 1 Please insert the EasyBUILD into the optical drive 2 Expand Utilities Altos R520 Onboard SATA RAID select RAID Web Console 2 Windows and click on Setup 3 F...

Page 90: ...LD 8 0 build 100 or later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE There is no built in driver for Integrated SAS hardware RAID in the Red Hat Enterprise Linux 5 0 EM64T You need an external USB floppy drive for applying driver during the OS installation 4 Since Red Hat Enterprise Linux 5 0 EM6...

Page 91: ...all the driver cd tmp src make install insmod e1000 ko 4 Run the kudzu utility it will auto detect the Gigabit Ethernet controller and help you to configure it kudzu 5 Restart the network service to bring up both of the network interfaces service network restart IOAT driver installation 1 Please remove the old version of IOAT driver from the system manually cd lib modules uname r kernel drivers dm...

Page 92: ... r520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v2_19_01 zip chmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 on select applications System Tools RAID Web Console 2 Startup UI Red Hat Enterprise Linux 5 0 EM64T Installation with integrated S...

Page 93: ...stallation 1 Since Red Hat Enterprise Linux 5 0 EM64T cannot recognize the integrated SAS hardware RAID 2 you need to make a driver diskette from the EasyBUILD first before the installation 2 Type linux dd when the prompt boot appears at the start 3 Please select the sda as the Driver Disk Source 4 Follow the instruction to load the integrated SAS hardware RAID 2 driver from the driver diskette 5 ...

Page 94: ...es uname r kernel drivers dma mv ioatdma ko ioatdma ko bak 2 You can find the IOAT driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first Copy the IOAT driver to tmp cd tmp tar zxf ioatdma ioat version tar gz 3 Install the IOAT driver cd ioatdma ioat version make install 4 Load the IOAT driver modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT...

Page 95: ...ole 2 Startup UI Red Hat Enterprise Linux 5 0 EM64T Installation with integrated SAS SW RAID Below information describes how to manually install Red Hat Enterprise Linux 5 0 EM64T on Altos R520 with integrated SAS SW RAID Drivers Required For Red Hat Enterprise Linux 5 0 EM64T Installation the following device drivers are required Device Version EasyBUILD Version Integrated SAS hardware RAID 09 32...

Page 96: ...ruction to load the integrated SAS hardware RAID driver from the driver diskette 5 At the package selection step select Software Development for the installation package 6 Please follow the normal procedure to finish the installation Gigabit Ethernet Driver Installation NOTE Please install the kernel devel version package with the CD 1 of Red Hat Enterprise Linux 5 EM64T prior to install the Gigab...

Page 97: ... modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT driver installation completed you could see subdirectories and files for each subdirectory of sys class dma folder RAID Utility Installation NOTE Please install the compat libstdc 296 2 96 138 i386 rpm and compat libstdc 33 3 2 3 61 i386 rpm packages with the CD 3 of Red Hat Enterprise Linux 5 EM64T prior to ins...

Page 98: ... later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 6 5 EasyBUILD 8 0 build 100 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in IOAT 2 15 EasyBUILD 8 0 build 200 or later Software Required The management utility of onboard SATA RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 2 19 01 EasyBUILD 8 0 build 100 or later Configu...

Page 99: ... installation Gigabit Ethernet Driver Installation NOTE Please install the kernel devel version package with the CD 1 of Red Hat Enterprise Linux 5 EM64T prior to install the Gigabit Ethernet driver 1 You can find the Gigabit Ethernet driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first mount dev dvd mnt cp R mnt Disk R520 NIC Intel pro1000 lx tmp 2 Remove the OS built in NIC...

Page 100: ...s and files for each subdirectory of sys class dma folder RAID Utility Installation NOTE Please install the compat libstdc 296 2 96 138 i386 rpm and compat libstdc 33 3 2 3 61 i386 rpm packages with the CD 3 of Red Hat Enterprise Linux 5 EM64T prior to install the RAID Web Console 2 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount med...

Page 101: ...OAT 2 15 EasyBUILD 8 0 build 200 or later Software Required The management utility of integrated SAS hardware RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 2 19 01 EasyBUILD 8 0 build 100 or later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE There is no bu...

Page 102: ...o1000 lx tmp 2 Remove the OS built in NIC driver rmmod e1000 ko 3 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 4 Run the kudzu utility it will auto detect the Gigabit Ethernet controller and help you to configure it kudzu 5 Restart the network service to bring up both of the network interfaces service network restart IOAT driver installat...

Page 103: ...yBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorder cp R media cdrecorder app r520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v2_19_01 zip chmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 on select applicatio...

Page 104: ... for Integrated SAS hardware RAID 2 in the Red Hat Enterprise Linux 5 0 You need an external USB floppy drive for applying driver during the OS installation 1 Since Red Hat Enterprise Linux 5 0 cannot recognize the integrated SAS hardware RAID 2 you need to make a driver diskette from the EasyBUILD first before the installation 2 Type linux dd when the prompt boot appears at the start 3 Please sel...

Page 105: ...e it kudzu 5 Restart the network service to bring up both of the network interfaces service network restart IOAT driver installation 1 Please remove the old version of IOAT driver from the system manually cd lib modules uname r kernel drivers dma mv ioatdma ko ioatdma ko bak 2 You can find the IOAT driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first Copy the IOAT driver to t...

Page 106: ...tmp unzip ir3_Linux_RWC2_v2_19_01 zip chmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 on select applications System Tools RAID Web Console 2 Startup UI Red Hat Enterprise Linux 5 0 Installation with integrated SAS SW RAID Below information describes how to manually install Red Hat Enterprise ...

Page 107: ...skette from the EasyBUILD first before the installation 2 Type linux dd when the prompt boot appears at the start 3 Please select the sda as the Driver Disk Source 4 Follow the instruction to load the integrated SAS hardware RAID driver from the driver diskette 5 At the package selection step select Software Development for the installation package 6 Please follow the normal procedure to finish th...

Page 108: ...LD to HDD first Copy the IOAT driver to tmp cd tmp tar zxf ioatdma ioat version tar gz 3 Install the IOAT driver cd ioatdma ioat version make install 4 Load the IOAT driver modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT driver installation completed you could see subdirectories and files for each subdirectory of sys class dma folder RAID Utility Installation ...

Page 109: ...0 on Altos R520 with onboard SATA RAID Drivers Required For Red Hat Enterprise Linux 5 0 Installation the following device drivers are required Device Version EasyBUILD Version Integrated SAS hardware RAID 09 32 0207 20 08 EasyBUILD 8 0 build 100 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 6 5 EasyBUILD 8 0 build 100 or later Onboard VGA N A OS built in Onboard USB 2 0 N A ...

Page 110: ... driver list and select LSI megasr Driver version in the list 9 Follow the instruction to load the integrated SAS hardware RAID driver from the driver diskette 10 At the package selection step select Software Development for the installation package 11 Please follow the normal procedure to finish the installation Gigabit Ethernet Driver Installation NOTE Please install the kernel devel version pac...

Page 111: ...ver cd ioatdma ioat version make install 4 Load the IOAT driver modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT driver installation completed you could see subdirectories and files for each subdirectory of sys class dma folder RAID Utility Installation NOTE Please install the compat libstdc 296 2 96 138 i386 rpm and compat libstdc 33 3 2 3 61 i386 rpm packages...

Page 112: ...g device drivers are required Device Version EasyBUILD Version Integrated SAS hardware RAID 00 00 03 03 EasyBUILD 7 1 build 400 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 0 38 NAPI EasyBUILD 7 1 build 400 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Software Required The management utility of integrated SAS hardware RAID can be found in the EasyBUIL...

Page 113: ...it Ethernet Driver Installation 1 You can find the Intel 82546EB driver in EasyBUILD Please refer to directory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder cp R media cdrecorder Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3...

Page 114: ...Version EasyBUILD Version Integrated SAS hardware RAID 2 00 00 03 18 EasyBUILD 8 0 build 200 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 0 3 3 3 EasyBUILD 8 0 build 200 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Software Required The management utility of integrated SAS hardware RAID 2 can be found in the EasyBUILD Software Version EasyBUILD Version ...

Page 115: ...Intel 82546EB driver in EasyBUILD Please refer to directory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder cp R media cdrecorder Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the kudzu utility it will auto detect the Inte...

Page 116: ...6 EasyBUILD 7 1 build 400 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 0 38 NAPI EasyBUILD 7 1 build 400 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Software Required The management utility of integrated SAS SW RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring...

Page 117: ... in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder cp R media cdrecorder Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the kudzu utility it will auto detect the Intel 82563EB network controller and help you to configure it kudzu 4 Restart the net...

Page 118: ...asyBUILD 7 1 build 400 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Software Required The management utility of onboard SATA RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring onboard SATA RAID Please refer to the Appendix C for the onboard SATA RAID configuration Installation Tips NO...

Page 119: ...IC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the kudzu utility it will auto detect the Intel 82563EB network controller and help you to configure it kudzu 4 Restart the network service to bring up both of the network interfaces service network restart RAID Utility Installation 1 You can find the RAID Web Co...

Page 120: ... 2 0 N A OS built in Software Required The management utility of integrated SAS hardware RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE There is no built in driver Integra...

Page 121: ... driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the kudzu utility it will auto detect the Intel 82563EB network controller and help you to configure it kudzu 4 Restart the network service to bring up both of the network interfaces service network restart RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the...

Page 122: ...can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 2 63 EasyBUILD 8 0 build 200 or later Configuring integrated SAS hardware RAID 2 Please refer to the APPENDIX D for the integrated SAS hardware RAID 2 configuration Installation Tips NOTE There is no built in driver Integrated SAS hardware RAID 2 in the Red Hat Enterprise Linux 4 0 Update2 You need an external USB ...

Page 123: ...src make install insmod e1000 ko 3 Run the kudzu utility it will auto detect the Intel 82563EB network controller and help you to configure it kudzu 4 Restart the network service to bring up both of the network interfaces service network restart RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorde...

Page 124: ...D Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring integrated SAS SW RAID Please refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE There is no built in driver Integrated SAS SW RAID in the Red Hat Enterprise Linux 4 0 Update2 You need an external USB floppy drive to load driver during the OS install...

Page 125: ... Run the kudzu utility it will auto detect the Intel 82563EB network controller and help you to configure it kudzu 4 Restart the network service to bring up both of the network interfaces service network restart RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorder cp R media cdrecorder app R520 r...

Page 126: ...oftware Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring onboard SATA RAID Please refer to the Appendix C for the onboard SATA RAID configuration Installation Tips NOTE There is no built in driver Onboard SATA RAID in the Red Hat Enterprise Linux 4 0 Update2 You need an external USB floppy drive to load driver during the OS installation 1 Since Red ...

Page 127: ...lp you to configure it kudzu 4 Restart the network service to bring up both of the network interfaces service network restart RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt app R520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v...

Page 128: ...later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE The driver of Integrated SAS hardware RAID is required for the SUSE Linux Enterprise Server 10 EM64T installation Please install an external USB floppy drive for applying driver during the OS installation 1 Since SUSE Linux Enterprise Server 10 EM6...

Page 129: ...even though you ve inserted the installation CD 2 In this case please press Ctrl Alt F2 to switch to another terminal Issue the reboot command to reboot the system Then remove the driver diskette and continue the installation 8 Follow the instruction to complete the installation with remained installation CDs Gigabit Ethernet Driver Installation 1 You can find the Intel 82546EB driver in EasyBUILD...

Page 130: ...site http csd acer com tw SI Download2006 nsf ServerWeb or EasyBUILD 8 0 build 100 or later 1 Please remove the old version of IOAT driver from the system manually cd lib modules uname r kernel drivers dma mv ioatdma ko ioatdma ko bak 2 You can find the IOAT driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first Copy the IOAT driver to tmp cd tmp tar zxf ioatdma ioat version ta...

Page 131: ...Linux Enterprise Server 10 EM64T Installation with integrated SAS hardware RAID 2 Below information describes how to manually install SUSE Linux Enterprise Server 10 EM64T on Altos R520 with integrated SAS hardware RAID 2 Drivers Required For SUSE Linux Enterprise Server 10 EM64T Installation the following device drivers are required The drivers can be found in the EasyBUILD 7 1 build 600 or later...

Page 132: ...e screen select Installation Then press F5 and select YES for the driver loading in the installation Press Enter to continue 4 Follow the instruction to load the integrated SAS hardware RAID 2 driver from the driver diskette 5 At the Installation Settings select the Software and click on Details Select Package Groups in the Filter drop down menu then click Development sources to add kernel package...

Page 133: ...ctory of the 82546EB driver in Driver Required section above and copy the driver from the EasyBUILD 7 1 to HDD first mount media dvdram cp R media dvdram Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the YaST2 utility YaST2 4 Select Network Devices Network Card it will auto detect the Intel 82563E...

Page 134: ...oatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT driver installation completed you could see subdirectories and files for each subdirectory of sys class dma folder RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD 7 1 Please refer to the directory of the RAID Web Console 2 in Software Required section above and copy the utility from the EasyBUILD 7 1 ...

Page 135: ...re Required The management utility of integrated SAS SW RAID can be found in the EasyBUILD 7 1 build 600 or later Software Version EasyBUILD Version RAID Web Console 2 1 19 00 EasyBUILD 7 1 build 600 or later Configuring integrated SAS SW RAID Please refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE The driver of Integrated SAS SW RAID is required for the ...

Page 136: ...zed as sda but SuSE Linux still tries to load system files from sdb To solve this issue the grub menu list file and the fstab file needs to be modified 8 At prompt type the following command to mount file system on mass storage mount dev sda2 tmp Edit the grub menu list file to change all entries with sdb to sda tmp bin vi tmp boot grub menu lst Next edit the fstab file to change all entries with ...

Page 137: ... manually cd lib modules uname r kernel drivers dma mv ioatdma ko ioatdma ko bak 2 You can find the IOAT driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first Copy the IOAT driver to tmp cd tmp tar zxf ioatdma ioat version tar gz 3 Install the IOAT driver cd ioatdma ioat version make install 4 Load the IOAT driver modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll s...

Page 138: ...e Server 10 EM64T on Altos R520 with onboard SATA RAID Drivers Required For SUSE Linux Enterprise Server 10 EM64T Installation the following device drivers are required Device Version EasyBUILD Version Onboard SATA RAID 06 28 1110 20 06 EasyBUILD 7 1 build 600 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 3 15 NAPI EasyBUILD 7 1 build 600 or later Onboard VGA N A OS built in ...

Page 139: ... Groups in the Filter drop down menu then click Development sources to add kernel package Select Patterns in the Filter drop down menu then add C C Compiler and Tools packages 6 Follow the instruction to complete the installation of CD 1 7 After system reboot the following message would appears resume device dev sdb1 not found ignoring waiting for device dev sdb2 to appear not found exiting to bin...

Page 140: ... Devices Network Card it will auto detect the Intel 82563EB network controller and help you to configure it IOAT driver installation NOTE Please update the onboard Gigabit Ethernet driver to version 7 6 5 or later prior to install IOAT driver you could found the driver from Acer GCSD website http csd acer com tw SI Download2006 nsf ServerWeb or EasyBUILD 8 0 build 100 or later 1 Please remove the ...

Page 141: ...hmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 click on start button select System More Programs RAID Web Console 2 Startup UI SUSE Linux Enterprise Server 9 EM64T Service Pack 3 Installation with integrated SAS hardware RAID Below information describes how to manually install SUSE Linux Ente...

Page 142: ...tion 2 Boot the system form SUSE Linux Enterprise Server 9 EM64T Service Pack3 bootable CD 3 When you see the boot menu on the screen select Installation press F6 then press Enter to continue 4 Follow the instruction to load the integrated SAS hardware RAID driver from the driver diskette 5 Follow the instruction to change the CD to SUSE Linux Enterprise Server 9 EM64T CD 1 6 At the Installation S...

Page 143: ...dia cdrecorder mnt cp R mnt app R520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v1 13 00 zip chmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 click on start button select System More Programs RAID Web Console 2 Startup UI SUSE Linux Enterpris...

Page 144: ...ed an external USB floppy drive to load driver during the OS installation 1 Since SUSE Linux Enterprise Server 9 EM64T Service Pack 3 cannot recognize the integrated SAS hardware RAID 2 you need to make a driver diskette from the EasyBUILD first before the installation 2 Boot the system form SUSE Linux Enterprise Server 9 EM64T Service Pack3 bootable CD 3 When you see the boot menu on the screen s...

Page 145: ...ard it will auto detect the Intel 82563EB network controller and help you to configure it RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt app R520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v1 13 00 zip chmod 755 install sh chm...

Page 146: ...n driver Integrated SAS SW RAID in the SUSE Linux Enterprise Server 9 EM64T Service Pack 3 You need an external USB floppy drive to load driver during the OS installation 1 Since SUSE Linux Enterprise Server 9 EM64T Service Pack 3 cannot recognize the integrated SAS SW RAID you need to make a driver diskette from the EasyBUILD first before the installation 2 Boot the system form SUSE Linux Enterpr...

Page 147: ... pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the YaST2 utility YaST2 4 Select Network Devices Network Card it will auto detect the Intel 82563EB network controller and help you to configure it RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to ...

Page 148: ...BUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring onboard SATA RAID Please refer to the Appendix C for the onboard SATA RAID configuration Installation Tips NOTE There is no built in driver Onboard SATA RAID in the SUSE Linux Enterprise Server 9 EM64T Service Pack 3 You need an external USB floppy drive to load driver during the OS installation 1 Since SUSE Linu...

Page 149: ...ory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the YaST2 utility YaST2 4 Select Network Devices Network Card it will auto detect the Intel 82563EB network con...

Page 150: ...0 or later Software Required The management utility of integrated SAS hardware RAID can be found in the EasyBUILD 7 1 build 600 or later Software Version EasyBUILD Version RAID Web Console 2 1 19 00 EasyBUILD 7 1 build 600 or later Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE The driver of Integrat...

Page 151: ...C Compiler and Tools packages 6 Follow the instruction to complete the installation of CD 1 7 Remove the driver diskette when system automatically reboot at the end of the installation process with CD 1 NOTE If the driver diskette is kept in the FDD you would see below message even though you ve inserted the installation CD 2 In this case please press Ctrl Alt F2 to switch to another terminal Issu...

Page 152: ...EB network controller and help you to configure it IOAT driver installation NOTE Please update the onboard Gigabit Ethernet driver to version 7 6 5 or later prior to install IOAT driver you could found the driver from Acer GCSD website http csd acer com tw SI Download2006 nsf ServerWeb or EasyBUILD 8 0 build 100 or later 1 Please remove the old version of IOAT driver from the system manually cd li...

Page 153: ...sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 click on start button select System More Programs RAID Web Console 2 Startup UI SUSE Linux Enterprise Server 10 Installation with integrated SAS hardware RAID 2 Below information describes how to manually install SUSE Linux Enterprise Server 10 on Altos R520 with integrated SAS hard...

Page 154: ...ith SUSE Linux Enterprise Server 10 CD 1 3 When you see the boot menu on the screen select Installation Then press F5 and select YES for the driver loading in the installation Press Enter to continue 4 Follow the instruction to load the integrated SAS hardware RAID 2 driver from the driver diskette 5 At the Installation Settings select the Software and click on Details Select Package Groups in the...

Page 155: ...ctory of the 82546EB driver in Driver Required section above and copy the driver from the EasyBUILD 7 1 to HDD first mount media dvdram cp R media dvdram Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the YaST2 utility YaST2 4 Select Network Devices Network Card it will auto detect the Intel 82563E...

Page 156: ...oatdma insmod ioatdma ko modprobe ioatdma ll sys class dma When IOAT driver installation completed you could see subdirectories and files for each subdirectory of sys class dma folder RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD 7 1 Please refer to the directory of the RAID Web Console 2 in Software Required section above and copy the utility from the EasyBUILD 7 1 ...

Page 157: ...Required The management utility of integrated SAS SW RAID can be found in the EasyBUILD 7 1 build 600 or later Software Version EasyBUILD Version RAID Web Console 2 1 19 00 EasyBUILD 7 1 build 600 or later Configuring integrated SAS SW RAID Please refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE The driver of Integrated SAS SW RAID is required for the SUS...

Page 158: ...zed as sda but SuSE Linux still tries to load system files from sdb To solve this issue the grub menu list file and the fstab file needs to be modified 8 At prompt type the following command to mount file system on mass storage mount dev sda2 tmp Edit the grub menu list file to change all entries with sdb to sda tmp bin vi tmp boot grub menu lst Next edit the fstab file to change all entries with ...

Page 159: ... manually cd lib modules uname r kernel drivers dma mv ioatdma ko ioatdma ko bak 2 You can find the IOAT driver in EasyBUILD Please copy the driver from the EasyBUILD to HDD first Copy the IOAT driver to tmp cd tmp tar zxf ioatdma ioat version tar gz 3 Install the IOAT driver cd ioatdma ioat version make install 4 Load the IOAT driver modprobe dca cd ioatdma insmod ioatdma ko modprobe ioatdma ll s...

Page 160: ... onboard SATA RAID Drivers Required For SUSE Linux Enterprise Server 10 Installation the following device drivers are required The drivers can be found in the EasyBUILD 7 1 build 600 or later Device Version EasyBUILD Version Onboard SATA RAID 06 28 1110 20 06 EasyBUILD 7 1 build 600 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 7 3 15 NAPI EasyBUILD 7 1 build 600 or later Onboa...

Page 161: ...s in the Filter drop down menu then click Development sources to add kernel package Select Patterns in the Filter drop down menu then add C C Compiler and Tools packages 6 Follow the instruction to complete the installation of CD 1 7 After system reboot the following message would appears resume device dev sdb1 not found ignoring waiting for device dev sdb2 to appear not found exiting to bin sh Th...

Page 162: ... Devices Network Card it will auto detect the Intel 82563EB network controller and help you to configure it IOAT driver installation NOTE Please update the onboard Gigabit Ethernet driver to version 7 6 5 or later prior to install IOAT driver you could found the driver from Acer GCSD website http csd acer com tw SI Download2006 nsf ServerWeb or EasyBUILD 8 0 build 100 or later 1 Please remove the ...

Page 163: ...755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and select 1 for full installation 4 To start RAID Web Console 2 click on start button select System More Programs RAID Web Console 2 Startup UI SUSE Linux Enterprise Server 9 Service Pack 3 Installation with integrated SAS hardware RAID Below information describes how to manually install SUSE Linux Enterprise Serv...

Page 164: ... Linux Enterprise Server 9 Service Pack 3 cannot recognize the integrated SAS hardware RAID you need to make a driver diskette from the EasyBUILD first before the installation 2 Boot the system form SUSE Linux Enterprise Server 9 Service Pack3 bootable CD 3 When you see the boot menu on the screen select Installation press F6 then press Enter to continue 4 Follow the instruction to load the integr...

Page 165: ...u to configure it RAID Utility Installation 1 You can find the RAID Web Console 2 in EasyBUILD Please copy the utility from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt app R520 raid Integrated_SAS Linux tmp 2 Install RAID Web Console 2 utility cd tmp unzip ir3_Linux_RWC2_v1 13 00 zip chmod 755 install sh chmod 755 RunRPM sh install sh 3 Type y to accept the license agreen and se...

Page 166: ...n Installation Tips NOTE There is no built in driver Integrated SAS hardware RAID 2 in the SUSE Linux Enterprise Server 9 Service Pack 3 You need an external USB floppy drive to load driver during the OS installation NOTE Before the installation please disable the Intel Speedstep technology setting You can find the option in BIOS setting Advanced Processor configuration Enhanced Intel Speedstep te...

Page 167: ...ory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make install insmod e1000 ko 3 Run the YaST2 utility YaST2 4 Select Network Devices Network Card it will auto detect the Intel 82563EB network con...

Page 168: ...USB 2 0 N A OS built in Software Required The management utility of integrated SAS SW RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring integrated SAS SW RAID Please refer to the Appendix B for the integrated SAS SW RAID configuration Installation Tips NOTE There is no built in driver Integrated SAS SW RAID...

Page 169: ...complete the installation Gigabit Ethernet Driver Installation 1 You can find the Intel 82546EB driver in EasyBUILD Please refer to directory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt Disk R520 NIC Intel pro1000 lx tmp 2 Change the directory to the driver source and install the driver cd tmp src make ins...

Page 170: ...board Chipset N A OS built in Onboard Gigabit Ethernet 7 0 38 NAPI EasyBUILD 7 1 build 400 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Software Required The management utility of onboard SATA RAID can be found in the EasyBUILD Software Version EasyBUILD Version RAID Web Console 2 1 13 07 EasyBUILD 7 1 build 400 or later Configuring onboard SATA RAID Please refer to the App...

Page 171: ...r you add the kernel source and C C Compiler and Tools please click on Accept and follow the instruction to complete the installation Gigabit Ethernet Driver Installation 1 You can find the Intel 82546EB driver in EasyBUILD Please refer to directory of the 82546EB driver in Driver Required section and copy the driver from the EasyBUILD to HDD first mount media cdrecorder mnt cp R mnt Disk R520 NIC...

Page 172: ...n EasyBUILD Version Integrated SAS hardware RAID 1 00 07 EasyBUILD 7 1 build 400 or later Onboard Chipset N A OS built in Onboard Gigabit Ethernet 9 22 EasyBUILD 7 1 build 400 or later Onboard VGA N A OS built in Onboard USB 2 0 N A OS built in Configuring integrated SAS hardware RAID Please refer to the Appendix A for the integrated SAS hardware RAID configuration Installation Tips NOTE There is ...

Page 173: ...the following message please select Modify Then move the cursor to Network boards and press Enter The following device drivers were detected for this server Add change or delete device drivers as needed Device types Driver names Network boards NetWare Loadable Modules optional 10 Please press INSERT key to insert the onboard Intel 82563EB Gigabit Ethernet driver After the drivers are successfully ...

Page 174: ...o the APPENDIX D for the integrated SAS hardware RAID 2 configuration Installation Tips NOTE There is no built in driver of integrated SAS hardware RAID 2 in the NetWare 6 5 SP5 You need an external USB floppy drive to load driver during the OS installation 1 Make a driver diskette for integrated SAS hardware RAID 2 and onboard Intel 82563EB Gigabit Ethernet from EasyBUILD 2 Boot the system from t...

Page 175: ...2563EB Gigabit Ethernet driver After the drivers are successfully loaded please select Return to driver summary 11 Then you would see the following message Please select Continue The following device drivers were detected for this server Add change or delete device drivers as needed Device types Driver names Network boards E1000E E1000E Network Loadable Modules optional 12 Please follow the normal...

Page 176: ...f the hard drive Advanced You specify all partition settings 8 Select how the ESX Server will boot in Advanced Optioins NOTE VMware recommends to keep the default setting of Form a drive install on the MBR of the drive option 9 Configure the ESX Serer host network IP address NOTE VMware recommends that you use a static IP address to simplify client access 10 Follow the instruction to complete the ...

Page 177: ...ient utility VMware Infrastructure Client Installation on Windows 1 To install the VMware Infrastructure Client utility on your console system 2 Launch VMware Infrastructure Client utility 3 Now you can manage the ESX Server or create virtual machines with the VMware Infrastructure Client utility ...

Page 178: ...Altos R520 Installation Configuration Guide 162 ...

Page 179: ...3 In the left panel select Adapter Properties The current adapter settings will be listed Please click on Next to change the setting 4 Change the setting of Set Factory Defaults from No to Yes then click on submit 5 Press Ctrl Alt Del to reboot the server Creating and Initialing a RAID Volume 6 In the left panel select Configuration Wizard 7 Select Add Configuration default and click on Next 8 Sel...

Page 180: ...onal SAS HDD 16 Enter the Intel RAID BIOS Console Virtual Configuration 17 Select a free disk marked as UNCONF GOOD and listed under Physical Drives 18 Select Make Global Dedicated HSP or Make Dedicated DSP and click on Go 19 Click on Home to go back to the configuration menu You will see the disk marked as Hotsapare in pink and listed under Physical Drives ...

Page 181: ... screen during the POST Power On Self Test press Ctrl E to enter the Embedded RAID II Configuration Utility Loading integrated SAS SW RAID default setting 25 Select Objects from Management menu 26 Select Adapter from Objects The selectable adapter will be listed 27 Press Enter on the adapter and the adapter setting will be shown on the screen You can change the setting from this menu 28 Select Fac...

Page 182: ...9 Press Esc to return to the Management Menu 40 Select Initialize from Management menu All logical drives should be listed under Logical Drives 41 Press Spacebar to select drives for initialization The selected drive will be shown in yellow 42 After selecting the drives press F10 and select YES to start the initialization process 43 When initialization is complete press any key to continue 44 Pres...

Page 183: ...ing the POST Power On Self Test press Ctrl E to enter the Embedded RAID II Configuration Utility Loading onboard SATA RAID default setting 6 Select Objects from Management menu 7 Select Adapter from Objects The selectable adapter will be listed 8 Press Enter on the adapter and the adapter setting will be shown on the screen You can change the setting from this menu 9 Select Factory Default and YES...

Page 184: ...0 Press Esc to return to the Management Menu 21 Select Initialize from Management menu All logical drives should be listed under Logical Drives 22 Press Spacebar to select drives for initialization The selected drive will be shown in yellow 23 After selecting the drives press F10 and select YES to start the initialization process 24 When initialization is complete press any key to continue 25 Pres...

Page 185: ...g 3 In the left panel select Adapter Properties The current adapter settings will be listed Please click on Next to change the setting 4 Change the setting of Set Factory Defaults from No to Yes then click on submit 5 Press Ctrl Alt Del to reboot the server Creating and Initialing a RAID Volume 6 In the left panel select Configuration Wizard 7 Select Add Configuration default and click on Next 8 S...

Page 186: ...onal SAS HDD 16 Enter the Intel RAID BIOS Console Virtual Configuration 17 Select a free disk marked as UNCONF GOOD and listed under Physical Drives 18 Select Make Global Dedicated HSP or Make Dedicated DSP and click on Go 19 Click on Home to go back to the configuration menu You will see the disk marked as Hotsapare in pink and listed under Physical Drives ...