116
Chapter 4
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE: Verify that all attached devices are supported by the computer.
NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 99.):
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
K
Non-Acer devices
K
Printer, mouse, and other external devices
K
Battery pack
K
Hard disk drive
K
DIMM
K
CD-ROM/Diskette drive Module
K
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
K
System board
K
LCD assembly
Summary of Contents for Aspire 2420
Page 6: ...VI ...
Page 10: ...X Table of Contents ...
Page 48: ...38 Chapter 1 ...
Page 106: ...96 Chapter 3 ...
Page 120: ...110 Chapter 4 F5h Boot to Mini DOS F6h Clear Huge Segment F7h Boot to Full DOS Code Beeps ...
Page 127: ...Chapter 5 117 Top View Jumper and Connector Locations Chapter 5 ...
Page 128: ...118 Chapter 5 Bottom View ...
Page 162: ...Appendix A 152 ...
Page 166: ...156 Appendix B ...
Page 168: ...158 Appendix C ...