Chapter 1
17
Environmental Requirements
Parameter
Limits
Operating Temperature
+5
o
C to +50
o
C (32
o
F to 131
o
F)
Note: Chassis design must provide airflow to avoid exceeding Intel
Xeon processor maximum case temperature.
Non-Operating
Temperature
-40
o
C to +70
o
C (-40
o
F to 158
o
F)
DC Voltage
+/- 5% of all nominal voltages
Non-Operating Humidity
90%, non-condensing @ 35
o
C
Acoustic noise
Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office
ambient temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical office ambient
temperature. (23 +/- 2 degrees C)
Shock (Unpackaged)
Trapezoidal, 50g, 170inches/sec
Shock (Packaged)(>/=40
lbs to <80 lbs)
24inches
Vibration (Unpackaged)
5Hz to 500Hz 3.13g RMS random
ESD
+/- 15KV per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
1826 BTU/ hour