Chapter 1
23
Hardware Monitor Function
Environment Requirements
Drop Test
Item
Description
Feature
•
Smart fan control system, Thermal Cruise and Speed Cruise support
•
Six VID input pins for CPU Vcore identification
•
Two thermal inputs from optionally remote thermistors or 2N3904
transistors or Pentium 4 thermal diode output
•
Four external voltage detect inputs
•
Three intrinsic voltage monitoring (typical for Vbat, +5VSB, +5CC)
•
Two fan speed monitoring inputs
•
Two fan speed control (DC analog output)
•
WATCHDOG comparison of all monitored items
•
Overheat indication output
•
Issue SMI#, IRQ, OVT# to activate system protection
Item
Specification
Temperature
Operating
+5
O
C ~ +35
O
C
Non-operating
-20
O
C ~ +60
O
C (storage packed), -10
O
C ~ +60
O
C (unpacked)
Humidity
Operating
15% to 80% RH, non-condensing
Non-operating
10% to 90% RH, non-condensing at 40
o
C
Vibration
Operating
5 ~ 500Hz, 2.20g RMS random, 10 minutes per axis in all three axes
Non-operating
5 ~ 500Hz, 1.09g RMS random, one hour per axis in all three axes
Drop Test
Definition
The protection ability of packing & cushion must be capable of
withstanding, with no physical or functional damage, mechanical impact
from height-specific drops.
Test Standard
Package Cross Weight
Drop Height
Not of Drop
KGs
lbs
CM
Inch
0~9.1
0~20
76
30
10
9.1~18.2
20~40
61
24
10
18.2~27.3
40~60
46
18
10
27.3~45.4
60~100
31
12
10
10 drops: one corner, three edges, six surfaces