3. Description for Using 

 

 

 

 

 

2.

 

 

 

 

 

- 7

 

 

 

3-2 MENU Description (Applying display units by changes in Mode) 

 

LCD light contrast 

 

In principle LCD adjust the contrast. When a product is shipped, LCD contrast is set at "10"

 

(25 as a standard). If the area is hot or it is summer time, set at 

5

7

(about 30

35

). 

If it is cold or winter time, set at 

12

15

(about 0

15

). The contrast can be adjusted 

from 1 to 20. 

 

   

Change of Sweep mode 

 

Adjust the frequency range of the unit to come into the Sweep Mode, and change the 
sweep mode. 

 

   

Applying display unit by 

Changes in Mode   

As the below table, apply the measuring unit, depending on the change in the Display 
Mode. VW ACE-1000 readout unit shows frequency (Hz) always, and simultaneously the 
chosen display unit is shown as below. 

     
 

 

MODE 

Measuring Unit 

Main display 

Applying sensors 

Mode 1 

Period(

μsec) 

μs 

All VW Sensors 

Mode 2 

10

3

Hz

2

 

10

3

Hz

2

 

VW Load Cells 

Mode 3 

Strain(με0.391) 

0.391 

VW Spot-weldable Strain 
Gage 

Mode 4 

Strain(με0.7756) 

0.7756 

VW Shotcrete Strain Gage 

Mode 5 

Strain(με3.304) 

3.304 

VW Embedment Strain 
Gage 

Mode 6 

Strain(με4.062) 

4.062 

VW Weldable Strain Gage 

 

Reference 

As A1000Pro saves only frequency (Hz), the saved data should be converted by it if you 
use other units. 

 

3-3 How to use ACE-1000 

 

 

 

Model ACE-1000 is effectively used as following. 
 

 Connect a jumper cable to the connector. 

 Press [ON] button. 

    (After popping up ACE's logo, it converts into the Main screen.) 

 Check out the sweep and unit, and press [MENU], [ENTER],   

    [

▲/LIGHT], [▼/SAVE] to set the basic menu.   

(See [3-1] for detailed specifications and [3-2] for MENU) 

 Connect with a signal cable by the clip of the jumper cable.   

    (See [3-1] for detailed specifications) 

 Record or save the output frequency. 

 Get rid of the clip and turn off power. 

 Download the data by connecting RS-232 cable to the computer. 

Summary of Contents for ACE-1000

Page 1: ...Warranty VW Data Recorder Model ACE 1000...

Page 2: ...akdown owing to carelessness has happened and other operations such as dealing with zero point are needed services would be provided at a minimum cost 3 But in the case the purpose of use is changed i...

Page 3: ...g 5 3 1 Detail description for the function 5 3 2 Description of MENU 6 3 3 How to use ACE 1000 7 4 Program usage 8 4 1 Connect ACE 1000 to computer 9 4 2 A1000Pro Connect 9 4 3 A1000Pro Edit 10 4 4 A...

Page 4: ...measurement Function to automatically shut off the power by user selection up to 60 minutes in 10 minutes to efficiently extend the battery life and the usage period and it can measure 30 hours conti...

Page 5: ...Setting mode of MENU Button Transducer Connector Connect to a jumper cable to measure the frequency RS 232 Connector It is useful to download or delete the saved data from the computer or to set the...

Page 6: ...Communication port RS 232 Port Temperature sensor Thermistor 3k RTD 2k Temperature resolution 0 1 Display 256 128 Graphic LCD Keyboard Membrane key 6 Function keys pad Data capacity 4 000 Data points...

Page 7: ...isplay Mode 2 103 Hz2 2 Click Display Mode 3 0 391 3 Click Display Mode 4 0 7756 4 Click Display Mode 5 3 304 5 Click Display Mode 6 4 062 1 Click LCD Contrast 10 LCD Brightness adjustment 2 Click POW...

Page 8: ...ease Click ID change decrease 1 Click Saving measured data 1 Click Return to main display Reference Used while the measured value is on the screen Transducer Connector 10pin Jumper Cable Connect 10Pin...

Page 9: ...Applying sensors Mode 1 Period sec s All VW Sensors Mode 2 103 Hz2 103 Hz2 VW Load Cells Mode 3 Strain 0 391 0 391 VW Spot weldable Strain Gage Mode 4 Strain 0 7756 0 7756 VW Shotcrete Strain Gage Mod...

Page 10: ...ike MS Excel Only Ace Instrument offers A1000Pro Application description The Application program belonging with our VW data recorder ACE 1000 named A1000pro exe can be also downloaded from our website...

Page 11: ...he shape of follow ACE 1000 Connect If operate the program display main screen as follows Icon of Edit and Down is not activated because this is not connect For connect of VW data recorder turn on the...

Page 12: ...ow that able to check for battery of data recorder and set an option of Clock setup Reading setup Save option Auto power break Clock setup The first you must set time of computer and VW data recorder...

Page 13: ...4 Program usage 5 11 Reading setup Reading setup menu can be remote control the Sweep mode and Temperature sensor type ACE 1000 Sweep mode change ACE 1000 Temp Sensor Type change...

Page 14: ...rding mode the oldest data is deleted and the latest data is saved when the save capacity is full If you choice Stop recording mode subsequent data is not save when the save capacity is full Auto powe...

Page 15: ...00Pro Down If click the Down icon in the connected screen display the screen that arranged all saved data in VW data recorder as follows When a screen listing all saved data appears click ID option it...

Page 16: ...ion of csv and dat for using in operation program like MS Excel And this make use of extension of txt for checking in text file program like WordPad After choose the txt file save it Then WordPad prog...

Page 17: ...ck the storage space and delete the data If you click the Erase button on the Down screen a question about full deletion will be displayed After confirmation all data will be deleted 4 5 A1000Pro Exit...

Page 18: ...with great force When not using the jumper cable put it in a bag or case and store it in a place where it will not be damaged Check battery voltage Confirm the voltage of the built in battery before o...

Page 19: ...ce from the measuring machine an amplifier should be installed in proportion of measurement distance to prevent drop of voltage for sensor transmission 8 Atmospheric pressure adjustment When manometer...

Page 20: ...5 17...