5. Calibration & Service 

 

 

 

 

 

 

 

 

 

- 16 

 

 

5-1 Maintenance 

 

Keeping 

 

Part from other goods or cover with attention sign not to be shocked or vibrated because 
ACE-1000 VW data recorder is a precise apparatus with built-in electronic circuit. 
Keep in well-ventilated room without direct light. Long exposure to direct light makes 
measuring malfunction due to extreme temperature change.

 

 

   

Carrying 

 

Take great care not to make big measuring errors based on changing zero point due to 
heavy impact or vibration in carrying. Do not put any heavy things on it, settle down and 
take actions not to be shocked when carrying in vehicles.

 

 

   

Keeping jumper cable 

 

Do not bend the jumper cable. Keep it carefully so that it will not be disconnection. When 
using it, do not pull it by pulling it hard or do not pull it with great force. When not using the 
jumper cable, put it in a bag or case and store it in a place where it will not be damaged.

 

 

   

Check battery voltage 

 

Confirm the voltage of the built-in battery before or after using it. 
Too low voltage makes no signal of the measuring by the sensor.

 

 

   

Check measurement value 

 

Please contact us if you think the measurement value is not correct when measuring the 
sensor.

 

 

5-2 Calibration & service 

 

Calibration 

 

Model ACE-1000 VW data recorder is revised and shipped with exact input / output 
specifications of the electric circuit by using each special rectifier. 
Therefore it allows for highly stable and reliable values in every VW sensor. 

   

 

Service 

 

For effectively using a VW data recorder without any trouble, it is strongly recommended to 
read the manual and to handle it consistently.   
We will check any defects or performances if there are any troubles. 
 
ACE INSTRUMENT A/S team 
Tel) +82-31-459-8753    Fax) +82-31-459-8758 
[email protected] 
www.aceinstrument.com 

 

Summary of Contents for ACE-1000

Page 1: ...Warranty VW Data Recorder Model ACE 1000...

Page 2: ...akdown owing to carelessness has happened and other operations such as dealing with zero point are needed services would be provided at a minimum cost 3 But in the case the purpose of use is changed i...

Page 3: ...g 5 3 1 Detail description for the function 5 3 2 Description of MENU 6 3 3 How to use ACE 1000 7 4 Program usage 8 4 1 Connect ACE 1000 to computer 9 4 2 A1000Pro Connect 9 4 3 A1000Pro Edit 10 4 4 A...

Page 4: ...measurement Function to automatically shut off the power by user selection up to 60 minutes in 10 minutes to efficiently extend the battery life and the usage period and it can measure 30 hours conti...

Page 5: ...Setting mode of MENU Button Transducer Connector Connect to a jumper cable to measure the frequency RS 232 Connector It is useful to download or delete the saved data from the computer or to set the...

Page 6: ...Communication port RS 232 Port Temperature sensor Thermistor 3k RTD 2k Temperature resolution 0 1 Display 256 128 Graphic LCD Keyboard Membrane key 6 Function keys pad Data capacity 4 000 Data points...

Page 7: ...isplay Mode 2 103 Hz2 2 Click Display Mode 3 0 391 3 Click Display Mode 4 0 7756 4 Click Display Mode 5 3 304 5 Click Display Mode 6 4 062 1 Click LCD Contrast 10 LCD Brightness adjustment 2 Click POW...

Page 8: ...ease Click ID change decrease 1 Click Saving measured data 1 Click Return to main display Reference Used while the measured value is on the screen Transducer Connector 10pin Jumper Cable Connect 10Pin...

Page 9: ...Applying sensors Mode 1 Period sec s All VW Sensors Mode 2 103 Hz2 103 Hz2 VW Load Cells Mode 3 Strain 0 391 0 391 VW Spot weldable Strain Gage Mode 4 Strain 0 7756 0 7756 VW Shotcrete Strain Gage Mod...

Page 10: ...ike MS Excel Only Ace Instrument offers A1000Pro Application description The Application program belonging with our VW data recorder ACE 1000 named A1000pro exe can be also downloaded from our website...

Page 11: ...he shape of follow ACE 1000 Connect If operate the program display main screen as follows Icon of Edit and Down is not activated because this is not connect For connect of VW data recorder turn on the...

Page 12: ...ow that able to check for battery of data recorder and set an option of Clock setup Reading setup Save option Auto power break Clock setup The first you must set time of computer and VW data recorder...

Page 13: ...4 Program usage 5 11 Reading setup Reading setup menu can be remote control the Sweep mode and Temperature sensor type ACE 1000 Sweep mode change ACE 1000 Temp Sensor Type change...

Page 14: ...rding mode the oldest data is deleted and the latest data is saved when the save capacity is full If you choice Stop recording mode subsequent data is not save when the save capacity is full Auto powe...

Page 15: ...00Pro Down If click the Down icon in the connected screen display the screen that arranged all saved data in VW data recorder as follows When a screen listing all saved data appears click ID option it...

Page 16: ...ion of csv and dat for using in operation program like MS Excel And this make use of extension of txt for checking in text file program like WordPad After choose the txt file save it Then WordPad prog...

Page 17: ...ck the storage space and delete the data If you click the Erase button on the Down screen a question about full deletion will be displayed After confirmation all data will be deleted 4 5 A1000Pro Exit...

Page 18: ...with great force When not using the jumper cable put it in a bag or case and store it in a place where it will not be damaged Check battery voltage Confirm the voltage of the built in battery before o...

Page 19: ...ce from the measuring machine an amplifier should be installed in proportion of measurement distance to prevent drop of voltage for sensor transmission 8 Atmospheric pressure adjustment When manometer...

Page 20: ...5 17...

Reviews: