background image

Electrical 

Connection

Page6

STEP3

A

A

B

B

C

C

D

D

Switch for A, B, C

Switch for D, E

Working

Low Voltage Indicater

(Red LED)

DC sockets for 
12VDC LED lamp

DC socket for 5.5VDC 
mobile phone

Mobile Phone
(not included)

Note: 

Ensure correct connection as indicated. 
The red  LED is a low voltage indicator. 
If the battery is low, red LED will turn 
on, and the lamp will stop working. 
The red indicator light is also the 
indicator of failure. The red light will 
turn on in the case of overload or short 
circuit, at the same time, the power 
supply will be cut off. Turn off the main 
switch, eliminate the failure and the red 
light will be off.

E

E

STEP2

Before initial use or non-use of two months, please charge the battery for more than 
20 hours in sunny day.

PV

 

Module

DC socket for 12VDC PV module

Charging Indicater

(Yellow LED)

Yellow LED Mode:

 

·

 ON----Battery is charging.

·

 Flash----Battery is fully charged.

 

AC Power Supply

Charging

Warning:

The Power Pack can be supplied with the AC adaptor with special 
configuration. Please do not use other AC adaptor not supplied by 
use. This may influence the electrical properties of the products.

Main Switch

AC Adaptor(Optional)

Summary of Contents for BSS-00504S

Page 1: ...Solar LED Matrix Lamp Kit User Manual Product Specifications Model BSS 00504S...

Page 2: ...Page5 Page7 Page8 Page9 Page9 General Information Storage Tips and Operating Environment Components Kit How Solar Home System Works Specifications Installation Electrical Connection Maintenance Troub...

Page 3: ...Operating Temperature Range 14 F to 122 F Humidity Range 0 90 Page1 Due to the phenomenon of the self discharge of battery before initial use or non use of two months please charge the battery for mo...

Page 4: ...Battery Switch DC output for mobile phone DC output for lamp How Solar Home System Works System components Components Kit Your system should include all the following components If there is anything...

Page 5: ...y DC Lamp 4pcs Charging Time Continuous Use Operating Temperature Range Battery Type Capacity Light Source Rate Power Rate Voltage Rate Current Luminosity 12V 1A 2mA 5W 17V 0 29A 21 6V 0 34A Maintenan...

Page 6: ...om fountains sea spray Do not install module near flammable gases Do not install module on smooth roof Flammable Gases The light intensity of street light can not recharge to battery throught solar pa...

Page 7: ...tected use only Hang the lamp based on requirements Knock two nails into the wall which the PowerPack is going to be installed with the distance of 100mm between the two nails Hang the Power Pack on t...

Page 8: ...verload or short circuit at the same time the power supply will be cut off Turn off the main switch eliminate the failure and the red light will be off E E STEP2 Before initial use or non use of two m...

Page 9: ...essary Use water and a soft sponge or cloth for cleaning A mild non abrasive cleaning agent can be used if necessary Do not use dishwasher detergent Protect the cables against mechanical stress when t...

Page 10: ...w light flashes If connected to a load the battery discharges soon The red light is on The main switch is not turned on Turn on the main switch The connector of solar panel is loose There is something...

Page 11: ...shall not be liable if there has been service or repair carried out by any nuauthorized person unusual use wrong installation or bad system design Does not apply for system which in the estimate were...

Page 12: ......