NOTE

Introduction for buttons on 

remote controller 

Press this button to turn on the unit. Press this 

button  again to turn off the unit.

Press this button to select your required operat-

ion mode.

MODE

HEAT

FAN

DRY

AUTO COOL

TURBO

adjust fan blowing angle.

Under COOL or HEAT mode, press this button to

When selecting heating mode, the air condition-

er operates under heat mode. Press " " or "    " 

button to adjust set temperature. Press "FAN" 

button to adjust fan speed. Press "     " / "    " 

button to adjust fan blowing angle. (Cooling 

only unit won't receive heating mode signal. If 

setting heat mode with remote controller, press 

ON/OFF button can’t start up the unit).  

NOTE

 

  

 

 

 

When selecting auto mode, air conditioner will

operate automatically according to factory

setting. Press "FAN" button to adjust fan

speed. Press "     " / "    " button can adjust fan

blowing angle.

After selecting cool mode, air conditioner will

operate under cool mode. Press " " or " "

button to adjust set temperature. Press "FAN"

button to adjust fan speed. Press "    " / " "

button to adjust fan blowing angle.

When selecting dry mode, the air conditioner

operates at low speed .Under dry mode, fan 

speed cannot be adjusted.

Press"     " / "     " button to adjust fan blowing

angle. When selecting fan mode, the air 

conditioner will only blow fan, no cooling and no 

heating. All indicators are OFF. Press "

FAN" button to adjust fan speed. Press "     " 

/ "    " button to

 

For preventing cold air, after starting up heating mode, 
indoor unit will delay 1~5 minutes to blow air (actual 
delay time is depend on indoor ambient temperature).
Set temperature range from remote controller: 
16~30

 (61-86°F);

 

Under auto mode, temperature can be displayed; 

 

Under auto mode, set temperature can be adjusted.
This mode indicator is not available for some models.

FAN

, then back to Auto.

, to

,

NOTE

This button is used for setting Fan Speed in the 

sequence that goes from AUTO,

,     ,

,

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

This is a general use remote controller. It could be

used for the air conditioner with multifunction. For the

functions which the model doesn't have, if press the

corresponding button on the remote controller, the unit

will keep the original running status.

After putting through the power, the air conditioner will

give out a sound. Power indicator "     " is ON. After

that, you can operate the air conditioner by using

remote control.

Under on status, pressing the button on the remote

control, the signal icon "       " on the display of

remote control will blink once and the air conditioner

will give off a " ding " sound, which means the signal

has been sent to the air conditioner.

As for the models with functions of WiFi or wired

controller, the indoor unit must be controlled by a

standard remote control under auto mode first, and

then the function of adjustable temperature under auto

mode can be realized by APP or the wired controller.

This remote control can adjust the temperature

under auto mode. When matching with the unit which

is without the function of adjustable temperature under

auto mode, the set temperature under auto mode may

be invalid, or the displayed set temperature on the unit

is not same as that on the remote control under

auto mode.

7

Under AUTO speed, air conditioner will select proper 
fan speed automatically according to factory default
setting.
It

'

s low fan speed under dry mode.

X-FAN function: Holding fan speed button for 2s in
cool or dry mode, the icon 

"

      

"

 is displayed and the

indoor fan will continue operation for a few minutes in 
order to dry the indoor unit even though you have
turned off the unit. After energization, X-FAN OFF is
defaulted. X-FAN is not available in auto, fan or heat
mode.
This function indicates that moisture on evaporator of
indoor unit will be blowed after the unit is stopped to
avoid mould.

Having set X-FAN function on: After turning off the
unit by pressing ON/OFF button, indoor fan will
continue running for a few minutes at low speed. In
this period, hold fan speed button for 2s to stop
indoor fan directly.
Having set X-FAN function off: After turning off the
unit by pressing ON/OFF button, the complete unit
will be off directly.

ON/OFF

Summary of Contents for CHD09KCH19S

Page 1: ...lease read this owner s manual carefully before operating the unit and keep it for future reference Owner s Manual DUCTLESS SINGLE ZONE HEAT PUMP Models CHD09KCH19S CHD12KCH17S CHD18KCH17S CHD24KCH18S...

Page 2: ...06 12 13 14 16 19 20 Parts name Operation and introduction of remote controller Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operatio...

Page 3: ...easons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information use...

Page 4: ...h the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...

Page 5: ...used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other ante...

Page 6: ...conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The grounding...

Page 7: ...e appliance mustbe positioned so that theplug is accessible For the airconditioner withplug theplug should be re achable after finishing in stallation For the air conditioner with out plug a circuit b...

Page 8: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...to the actual display If remote controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel a...

Page 11: ...mp Outdoor ambient temp temp Indoor ambient Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Temp Dry mode Fan mode Heat mode display type I feel Set fan spe...

Page 12: ...h multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 13: ...imum angle When selecting air condition er is blowing fan at a xed position Horizontal louver will stop at the xed position Press or button once to increase or decrease set temperature by 1 F Holding...

Page 14: ...erature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of factory settings 2 Adjust an...

Page 15: ...nd 8 heating function can t operate at the same time If 8 heating function has been set under heat mode press SLEEP button will cancel 8 heating function If sleep function has been set under heat mode...

Page 16: ...the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 17: ...s to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard rials Please dispose them in appropriate recycling unit If you want to dispose of the air conditio...

Page 18: ...or unit is leaking Power failure Is plug loose Reinsert the plug Do not repair or refit the air conditioner by yourself If the air conditioner operates under abnormal conditions it may cause malfuncti...

Page 19: ...Otherwise it may cause abnormal operation wrong action mechanical malfunction or even serious safety accident sure that the unit is running in cooling mode Then fully close the valve at high pressure...

Page 20: ...h the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket...

Page 21: ...s when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led ou...

Page 22: ...ue N m NOTE Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided All wires of indoor unit and outdoor unit should be If the le...

Page 23: ...er cord for installation when binding th em When binding to a certain degree sep arate the indoor power and then separate the drain hose Do not bend the drain hose too excessively in order to prevent...

Page 24: ...tion or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of...

Page 25: ...pipe The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging...

Page 26: ...pipe A mm Max Min 6 6 35 1 4 1 3 0 7 1 6 1 0 9 9 52 3 8 12 12 7 1 2 1 8 1 0 15 8 16 5 8 2 4 2 2 Outer diameter mm 26 7 19 4 80 67 50 24 Remove the union nut on the indoor connection 122 75 cooling Max...

Reviews: