ACD CHD09KCH19S Owner'S Manual Download Page 14

I FEEL


NOTE

CLOCK

SLEEP

Press this button, can select Sleep 1 (     1),

Sleep 2 (      2), Sleep 3 (      3) and cancel the

Sleep, circulate between these, after electrified, 

Sleep Cancel is defaulted.

9

 
 

Clock time adopts 24-hour mode.
The interval between two operations can

'

t exceed 5s.

Otherwise, remote control will quit setting status.
Operation for TIMER ON/TIMER OFF is the same.

Sleep 1 is Sleep mode 1, in Cool modes; sleep

status after run for one hour, the main unit setting

temperature will increase 1 , two hours, setting

temperature increased 2

, then the unit will run at

this setting temperature; In Heat mode: sleep

Sleep 2 is sleep mode 2, that is air conditioner

status after run for one hour, the setting tempera- 

ture will decrease 1 , two hours, setting tempera-

ture will decrease 2 , then the unit will run at this

setting temperature.

will run according to the presetting a group of 

sleep temperature curve.

Sleep 3-the sleep curve setting under Sleep

Press this button to set clock time. "      " icon on 

remote  controller  will  blink.  Press  " "  or  " " 

button within 5s to set clock time. Each pressing of 

" "  or  " "  button,  clock  time  will  increase  or 

decrease  1  min.  If  hold  " "  or  " "  button  ,  2s 

later,  time  will  change  quickly.  Release  this  button 

when  reaching  your  required  time.  Press  "CLOCK" 

button to confirm the time. "     " icon stops blink-

ing.

NOTE

 

Under on and off status, you can set T-OFF or T-ON

simultaneously.

Before setting T-ON or T-OFF, please adjust the

clock time.

After starting up T-ON or T-OFF,set the constant

circulating valid.

After that, air conditioner will be turned on or turned

off according to setting time. ON/OFF button has no

effect on setting. If you don’t need this function,

please use remote control to cancel it.

Sleep3- the sleep curve setting under Sleep

 

mode by DIY;

(1)Under Sleep 3 mode, press “TURBO” button for a

long time, remote control enters into user indi-

viduation sleep setting status, at this time, the time

of remote controller will display “1hour”, the setting

temperature “88” will display the corresponding

temperature of last setting sleep curve and blink

(The first entering will display according to the

initial curve setting value of  factory settings);

(2)Adjust “

” and “

” button,to change the

corresponding temperature, after adjusted,press

“TURBO” button for confirmation;

(3) At this time, 1hour will be automatically

increased at the timer position on the remote con-

trol, (that are "2hours" or "3hours" or "8hours"), the

place of setting temperature "88" will display the

corresponding temperature of last setting sleep

curve and blink;

(4) Repeat the above step (2)~(3) operation, until

8 hours temperature setting finished, sleep,curve

setting finished, at this time, the remote control

will resume the original timer display; temperature

display will resume to original setting temperature.

mode by DIY could be inquired:

The user could accord to sleep curve setting

method to inquire the presetting sleep curve, enter

into user individuation sleep setting status, but do

not change the temperature, press "TURBO" button

directly for confirmation. Note: In the above preset-

ting or enquiry procedure, if continuously within

10s, there is no button pressed, the sleep curve

setting status will be automatically quit and

resume the original display. In the presetting

or enquiry procedure, press

"ON/OFF" button, "MODE" button, "SLEEP" button,

the sleep curve setting or enquiry status will quit

similarly.

 

 

 

 

 

 

 

 

 

 

 

 

Press this button to start I FEEL function and "      "

will be displayed on the remote control. After this

function is set, the remote control will send the

detected ambient temperature to the controller

and the unit will automatically adjust the indoor te-

mperature according to the detected temperature.

Press this button again to cancel I FEEL function

and "

" will disappear.

Please put the remote control near user when this

function is set. Do not put the remote controller

near the object of high temperature or low temper-

ature in order to avoid detecting inaccurate ambie-

nt temperature.When I FEEL function is turned on,

the remote control should be put within the area

where indoor unit can receive the signal sent by the

remote controller.

 

Summary of Contents for CHD09KCH19S

Page 1: ...lease read this owner s manual carefully before operating the unit and keep it for future reference Owner s Manual DUCTLESS SINGLE ZONE HEAT PUMP Models CHD09KCH19S CHD12KCH17S CHD18KCH17S CHD24KCH18S...

Page 2: ...06 12 13 14 16 19 20 Parts name Operation and introduction of remote controller Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operatio...

Page 3: ...easons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information use...

Page 4: ...h the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...

Page 5: ...used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other ante...

Page 6: ...conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The grounding...

Page 7: ...e appliance mustbe positioned so that theplug is accessible For the airconditioner withplug theplug should be re achable after finishing in stallation For the air conditioner with out plug a circuit b...

Page 8: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...to the actual display If remote controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel a...

Page 11: ...mp Outdoor ambient temp temp Indoor ambient Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Temp Dry mode Fan mode Heat mode display type I feel Set fan spe...

Page 12: ...h multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 13: ...imum angle When selecting air condition er is blowing fan at a xed position Horizontal louver will stop at the xed position Press or button once to increase or decrease set temperature by 1 F Holding...

Page 14: ...erature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of factory settings 2 Adjust an...

Page 15: ...nd 8 heating function can t operate at the same time If 8 heating function has been set under heat mode press SLEEP button will cancel 8 heating function If sleep function has been set under heat mode...

Page 16: ...the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 17: ...s to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard rials Please dispose them in appropriate recycling unit If you want to dispose of the air conditio...

Page 18: ...or unit is leaking Power failure Is plug loose Reinsert the plug Do not repair or refit the air conditioner by yourself If the air conditioner operates under abnormal conditions it may cause malfuncti...

Page 19: ...Otherwise it may cause abnormal operation wrong action mechanical malfunction or even serious safety accident sure that the unit is running in cooling mode Then fully close the valve at high pressure...

Page 20: ...h the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket...

Page 21: ...s when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led ou...

Page 22: ...ue N m NOTE Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided All wires of indoor unit and outdoor unit should be If the le...

Page 23: ...er cord for installation when binding th em When binding to a certain degree sep arate the indoor power and then separate the drain hose Do not bend the drain hose too excessively in order to prevent...

Page 24: ...tion or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of...

Page 25: ...pipe The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging...

Page 26: ...pipe A mm Max Min 6 6 35 1 4 1 3 0 7 1 6 1 0 9 9 52 3 8 12 12 7 1 2 1 8 1 0 15 8 16 5 8 2 4 2 2 Outer diameter mm 26 7 19 4 80 67 50 24 Remove the union nut on the indoor connection 122 75 cooling Max...