12

1.

NOTICE

: Checking before use-season

4.

5.

Check whether air inlets and air outlets are bl-

Do not remove the panel when cleaning it.

Check whether drainage pipe is damaged.

 in good condition.

3.Check whether filter is clean.

Check whether mounting bracket for outdoor

NOTICE

   ocked.

2.Check whether air switch, plug and socket  are

unit is damaged or corroded . If yes, please

contact dealer.

NOTICE

:  Checking after use-season

1.

2.

3.

Clean and maintenance

 

■ 

2.

 

■ 

WARNING

WARNING

■ 

If there're other error codes, please contact  qu-

alified professionals for service.

■ 

■ 

■ 

■ 

Error Code

Error code

F2

E8

Disconnect power supply.

Clean filter and indoor unit’s panel.

Please contact qualified professionals for

service.

C5

F0

F1

Notice for recovery

Troubleshooting

1.

U8

H6

H3

E1

E5

E6

Many packing materials are recyclable mate-

Check whether mounting bracket for outdo or

unit is damaged or corroded. If yes, please

contact dealer.

Clean surface of indoor unit

When the surface of indoor unit is dirty, it is recomm-

ended to use a soft dry cloth or wet cloth to wipe it. 

The filter should be cleaned every three months .

If  there is much dust in the operation environme-

nt, clean frequency can be increased.

After removing the filter, do not touch fins to 

avoid injury.

Do not use fire or hair dryer to dry the filter to 

avoid deformation or fire hazard.

rials. Please dispose them in appropriate 

recycling unit.

If you want to dispose of the air conditioner, 

please contact local dealer or consultant service

center for the correct disposal method.

NOTE

It can be eliminated after restarting the unit.

If not, please contact qualified professionals

for service.

When air conditioner status is abnormal, tempe-

rature indicator on indoor uni t will blink to display

corresponding error code. Please refer  to below 

list for identification of error code. 

2.

4.

Clean filter

1.

3.


Open panel

Pull out the panel

to a certain angle

as shown in the fig.

Remove filter

 

Remove the filter as

indicated in the fig.

Turn off the air conditioner and disconnect the 

power before cleaning the air conditioner to av-

oid electric shock.

Do not wash the air conditioner with water to 

avoid electric shock.

Do not use volatile liquid to clean the air 

conditioner.

Do not use liquid or corrosive detergent to clean 

the appliance and do not splash water or other 

liquid onto it , otherwise, it may damage the 

plastic components , even cause electric shock.

Install filter

Install the filter and then close the panel cover

tightly. 

Clean filter

Use dust catcher or water to clean the filter.

When  the  filter  is  very  dirty,  use  the  water 

(below 45

) to clean it , and then put it in a 

shady and cool place to dry.

Summary of Contents for CHD09KCH19S

Page 1: ...lease read this owner s manual carefully before operating the unit and keep it for future reference Owner s Manual DUCTLESS SINGLE ZONE HEAT PUMP Models CHD09KCH19S CHD12KCH17S CHD18KCH17S CHD24KCH18S...

Page 2: ...06 12 13 14 16 19 20 Parts name Operation and introduction of remote controller Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operatio...

Page 3: ...easons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information use...

Page 4: ...h the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...

Page 5: ...used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other ante...

Page 6: ...conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The grounding...

Page 7: ...e appliance mustbe positioned so that theplug is accessible For the airconditioner withplug theplug should be re achable after finishing in stallation For the air conditioner with out plug a circuit b...

Page 8: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...to the actual display If remote controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel a...

Page 11: ...mp Outdoor ambient temp temp Indoor ambient Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Temp Dry mode Fan mode Heat mode display type I feel Set fan spe...

Page 12: ...h multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 13: ...imum angle When selecting air condition er is blowing fan at a xed position Horizontal louver will stop at the xed position Press or button once to increase or decrease set temperature by 1 F Holding...

Page 14: ...erature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of factory settings 2 Adjust an...

Page 15: ...nd 8 heating function can t operate at the same time If 8 heating function has been set under heat mode press SLEEP button will cancel 8 heating function If sleep function has been set under heat mode...

Page 16: ...the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 17: ...s to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard rials Please dispose them in appropriate recycling unit If you want to dispose of the air conditio...

Page 18: ...or unit is leaking Power failure Is plug loose Reinsert the plug Do not repair or refit the air conditioner by yourself If the air conditioner operates under abnormal conditions it may cause malfuncti...

Page 19: ...Otherwise it may cause abnormal operation wrong action mechanical malfunction or even serious safety accident sure that the unit is running in cooling mode Then fully close the valve at high pressure...

Page 20: ...h the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket...

Page 21: ...s when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led ou...

Page 22: ...ue N m NOTE Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided All wires of indoor unit and outdoor unit should be If the le...

Page 23: ...er cord for installation when binding th em When binding to a certain degree sep arate the indoor power and then separate the drain hose Do not bend the drain hose too excessively in order to prevent...

Page 24: ...tion or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of...

Page 25: ...pipe The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging...

Page 26: ...pipe A mm Max Min 6 6 35 1 4 1 3 0 7 1 6 1 0 9 9 52 3 8 12 12 7 1 2 1 8 1 0 15 8 16 5 8 2 4 2 2 Outer diameter mm 26 7 19 4 80 67 50 24 Remove the union nut on the indoor connection 122 75 cooling Max...