IX. STANDARD WARRANTY 

We warrant gas calibration equipment manufactured and sold by us to be 

free from defects in materials, workmanship and performance for a period 

of one year from date of shipment.  Any parts found defective within that 

period will be repaired or replaced, at our option, free of charge, F.O.B. 

factory.  This warranty does not apply to those items which by their nature 

are subject to deterioration or consumption in normal service, and which 

must be cleaned, repaired, or replaced on a routine basis.

Such items may include:

 

a. 

Electrochemical type generating cells

  b. Batteries

Warranty is voided by abuse including rough handling, mechanical damage, 

alteration, or repair procedures not in accordance with the instruction 

manual.  This warranty indicates the full extent of our liability, and we 

are not responsible for removal or replacement cost, local repair costs, 

transportation costs or contingent expenses incurred without our prior 

approval.

Advanced Calibration Designs, Inc.’s obligation under this warranty shall 

be limited to repairing or replacing, and returning any product which shall 

be returned to Advanced Calibration Designs, Inc. at its manufacturing 

facilities, with transportation charges prepaid, and which Advance Calibration 

Designs, Inc.’s Material Review Board examination shall disclose to its 

satisfaction to have been defective.

This warranty is expressed in lieu of any and all other warranties and 

representations, expressed or implied, and all other obligations or liabilities 

on the part of Advanced Calibration Designs, Inc. including, but not limited to, 

the warranty of fitness for a particular purpose.  In no event shall Advanced 

Calibration Designs, Inc. be liable for direct, incidental or consequential loss 

or damage of any kind connected with the use of its products or failure of 

its products to function or operate properly.

The following is a listing of the available electrochemical CAL-101 cells 

and their standard warranty when installed in equipment manufactured and 

supplied by Advanced Calibration Designs, Inc. 

Chlorine, Hydrogen, Hydrogen Sulfide, and Hydrogen Cyanide

 

- 2 Hour Cell -  2 hour of 

use

Page 11

Summary of Contents for CAL-101

Page 1: ...InstructionManual CalibrationGasGenerator AdvancedCalibrationDesigns Inc CAL 101...

Page 2: ...al Description Page 2 II Start Up Page 4 III Normal Operation Page 5 IV Non Normal Operation Page 6 V Cell Life Page 8 VI Corrections to Volumetric Flow Page 9 VII Maintenance Page 10 VIII Accessory I...

Page 3: ...can lead to improper calibrations This instrument conforms to the protection requirements of the EC DIRECTIVE 89 336 EEC on Electromagnetic Compatibility EMC in accordance with the provisions of Stat...

Page 4: ...is produced when the CAL 101 supplies a known amount of current and a known amount of air continuously to the cell Alkaline AA Batteries A set of two fully charged alkaline AA batteries provides 10 12...

Page 5: ...ed The bump generating cell is equipped with a switch to initiate a bump cycle In this configuration the cell remains in the instrument and automatically turns off after a 30 second bump cycle Deliver...

Page 6: ...ndicates that 2 hours remain on the cell 1 LED lit indicates less than 12 minutes of calibration time remain These are the normal operating conditions for the CAL 101 Complete equilibrium may take an...

Page 7: ...the delivery hose This adapter or cup is then placed over the gas sensor Be sure not to restrict or block the delivery hose while the pump is running This method is used for calibrating diffusion typ...

Page 8: ...corresponding pads on the cell for corrosion and attempt cleaning If the cell has been depleted it should be removed and replaced with a new generating cell Please refer to the section on cell life fo...

Page 9: ...er minute STP standard temperature and pressure of sea level and 20o C see chart in section VI To trim the flow hold the magnetic screw driver over the flow trim area of the instrument indicated with...

Page 10: ...plete list of correct cell part numbers please refer to the parts list at the end of this manual To replace the generating cell in the instrument press down firmly on the cell eject button at the top...

Page 11: ...ilized Note Altitude and Temperature are cumulative i e you must correct for both factors to obtain the most accurate calibration Altitude Correction Table Temperature Correction Table Altitude Correc...

Page 12: ...t fitting body panel mount 400 0000 00 Circuit board for CAL 101 Processor 400 0001 00 Circuit board for CAL 101 Interface 400 0002 00 Circuit board for CAL 101 pump assy 510 0101 00 Chlorine generati...

Page 13: ...ation Designs Inc s obligation under this warranty shall be limited to repairing or replacing and returning any product which shall be returned to Advanced Calibration Designs Inc at its manufacturing...

Page 14: ...tured by Advanced Calibration Designs Inc 2024 W McMillan St Tucson Arizona 85705 USA Phone 520 290 2855 Fax 520 290 2860 Int l Phone 001 520 290 2855 Fax 001 520 290 2860 Web site www GoACD com E mai...

Page 15: ...2024W McMillanSt Tucson Arizona85705USA Telephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0601 00 AdvancedCalibrationDesigns Inc...

Reviews: