1-4 The LC 1200 System LC 1200 Manual
Perimeter Door application
If desired, the LC unit can be used as a perimeter
door system. When in this mode, the door would
alarm the instant it was opened. If the door has
Magnetic Locks, the door would remain locked
(Lock energized) at all times and would require
a valid code entered into the Keypad or
activating a PBO to open the door. Delayed
Egress Circuitry would function normally if
3101 Magnetic Locks were used.
To use the LC unit as a perimeter door full time
remove the jumper from P1-1 and P1-2
(Perimeter Door) or to use the LC unit as a
perimeter part time use a Timer.
Alarms
Egress
Tamper
Power Loss Supervisor
Perimeter Door
The LC unit has the following alarms:
Egress
An Egress alarm occurs whenever a Tag enters
an LC unit’s Tx Activation Field
and
contacts
P2-3 and P2-4 of the LC unit are open (usually
interfaced with a Magnetic Switch or PIR).
Tamper
A Tamper alarm occurs when the LC unit cover
is removed and the Tamper Switch (S1) is
disengaged. Remember, JP2 (Tone Enable) must
be in place for this alarm to be heard.
Power Loss Supervisor (Optional)
A Power Loss Supervisor alarm occurs when a
charged 9V NiCAD battery is installed and the
LC unit loses power.
Remember, JP2 (Tone
Enable) must be in place for this alarm to be
heard.
Note:
This battery does not power the LC unit.
When the battery is installed and the power is
applied to the LC unit, the battery is being
trickle-charged constantly. When power is lost
to the LC unit, a Piezo Alert of the LC unit will
sound for as long as the 9-volt battery has
enough power to drive the Piezo.
WARNING:
For the Power Loss Supervise function, use a 9-
volt
Ni-Cad (nickel-cadmium)
rechargeable
battery ONLY as other types of batteries may
explode or leak causing damage to the LC unit
or injury to the person(s) working on the
equipment.
If a battery is not installed, make sure that the
battery clip cover is in place over the battery
lead terminals. If you have lost the cover, then
be sure to cover the terminals of the battery clip
with electrical tape or heat shrink tubing before
you apply power to the unit. Failure to do so
can result in the terminal leads shorting to
something conductive inside the unit and
causing damage to the LC unit or electric shock.
Summary of Contents for 800121
Page 1: ...LC 1200 Manual 800 356 2671 Accutech www accutech ics com...
Page 2: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 20: ......
Page 21: ...LC 1200 Manual Chapter 2 The LC unit...
Page 22: ......
Page 33: ...LC 1200 Manual Chapter 3 Tags TAD Part s 77L016 67L016 660021...
Page 34: ......
Page 43: ...LC 1200 Manual Chapter 4 The Magnetic Switch Part 650514...
Page 44: ......
Page 49: ...LC 1200 Manual Chapter 5 Passive Infrared Reader PIR Part 300302...
Page 50: ......
Page 54: ...5 4 Passive Infrared Reader PIR LC 1200 Manual Figure 5 4 Wiring the PIR...
Page 56: ......
Page 57: ...LC 1200 Manual Chapter 6 The Keypad Part 650202...
Page 58: ......
Page 68: ......
Page 69: ...LC 1200 Manual Chapter 7 Push Button Override PBO Part 700022...
Page 70: ......
Page 74: ...7 4 Push Button Override PBO LC 1200 Manual Figure 7 2 Wiring the PBO to the LC unit...
Page 75: ...LC 1200 Manual Chapter 8 External Sounders Part s 700216 300150...
Page 76: ......
Page 80: ......
Page 81: ...LC 1200 Manual Chapter 9 Magnetic Locks Part s 700218 700228...
Page 82: ......
Page 86: ...9 4 Magnetic Locks LC 1200 Manual Figure 9 1 3101 Magnetic Lock PCB...
Page 87: ...LC 1200 Manual Magnetic Locks 9 5 Figure 9 2 Wiring the 3101 Magnetic Lock...
Page 91: ...LC 1200 Manual Magnetic Locks 9 9 Figure 9 4 Wiring a 3000 Series Magnetic Lock...
Page 92: ......
Page 93: ...LC 1200 Manual Chapter 10 Elevator Deactivation Part 700027...
Page 94: ......
Page 98: ...10 4 Elevator Deactivation LC 1200 Manual Figure 10 2 Wiring Elevator Deactivation...
Page 99: ...LC 1200 Manual Chapter 11 Automatic Door Deactivation Part 700033...
Page 100: ......
Page 103: ...LC 1200 Manual Chapter 12 Fire Panel Interface FPI Part 700013...
Page 104: ......
Page 106: ...12 2 Fire Panel Interface FPI LC 1200 Manual Figure 12 1 The FPI with cabinet...
Page 109: ...LC 1200 Manual Chapter 13 Timer Part 700018...
Page 110: ......
Page 114: ......
Page 115: ...LC 1200 Manual Chapter 14 Alert Panels Part s 700080 700050 700052...
Page 116: ......
Page 119: ...LC 1200 Manual Alert Panels 14 3 14 2 Wiring a SAP or GDP FPI also shown...
Page 121: ...LC 1200 Manual Chapter 15 System Maintenance Testing...
Page 122: ......
Page 130: ......
Page 131: ...LC 1200 Manual Chapter 16 FAQ Troubleshooting...
Page 132: ......
Page 136: ......
Page 137: ...LC 1200 Manual Appendix A Component Cut Sheets...
Page 138: ......