Programming Parameters
Compact Readout Programming Parameters are listed below. Values in [ ]
are the available range of values that may be programmed for that
parameter.
Factory defaults are shown in
Bold
Red.
Pr 1 – Datum Key Value
[
0
to + 999.999in] or
[
0
to +9999.99mm]
This value will be recalled and displayed when the
DATUM
key is pressed
during normal operation (not during programming).
Default = 0
Pr 2 – Reading Direction
[
0
or 1]
This parameter controls the direction of measurement (positive vs negative)
when the measuring system is moved.
Default = 0
Pr 3 – Key Lockout
[
0
or 1]
This parameter controls the operation of the
+
,
-
and
DATUM
keys. If enabled,
(set to 1), these keys will not function and the
LOCK
symbol will appear on
the readout. This prevents accidental changes when depressing these keys
during normal operation.
Default = 0
Pr 4 – Resolution
[1,
2
or
3]
This parameter sets the number of places to the right of the decimal point on
the readout.
A value of 1 will display x.x.
A value of 2 will display x.xx
A value of 3 will display x.xxx
Default = 2
NOTE:
Decimal inch mode has a maximum of 3 places.
Millimeter mode has a maximum of 2 places (even if parameter is set to 3.)
Fractions mode is not affected by this setting.