![Accu-Flo Meter Service Red Jacket AGUMP33R1 Installation, Operation, Service & Repair Parts Download Page 30](http://html1.mh-extra.com/html/accu-flo-meter-service/red-jacket-agump33r1/red-jacket-agump33r1_installation-operation-service-and-repair-parts_3749377030.webp)
— 24 —
4” Petroleum & AG
4: Be certain all mating surfaces are clean. Install new functional element o-rings on
functional element (see figure 4.5). Install small o-ring in groove of packer. Carefully
set new functional element in place. Replace two 3/8” bolts and torque to 20-35 ft lb
(27-50 N•m).
5: If no siphon is used, make sure the vacuum port on the functional element is plugged
with a 3/8” NPT plug.
6:
Check the seating pressure of the adjustable Functional Element for proper setting.
R
EPLACING THE
C
APACITOR IN
P
ACKER
Serious injury or death can result from using a generic–type
capacitor. Generic–type capacitors do not contain internal
bleed resistors.
ALWAYS DISCONNECT and LOCK or TAG OUT the power
before starting to service the pump.
Capacitor is 440V, 17.5 µF continuous duty with internal bleed
resistor for 1/3 & 3/4 HP models. Capacitor is 440V, 25 µF
continuous duty with internal bleed resistor for 1-1/2 HP
models.
1:
Remove wiring compartment cover.
2: Remove retaining clip
3:
Pull out capacitor.
4:
Pull quick connectors.
5: Push connectors onto new capacitor.
6:
Push capacitor into wiring compartment. Clip into place.
7:
Reinstall capacitor cover. Do not use thread sealant. Torque to 35 ft lb (50 N•m).
I
NSTALLING A
R
EPLACEMENT
E
XTRACTABLE
P
UMP
If fixed length, skip to step 7
1:
Remove existing Red Jacket pump. (See “Removing the Pump” in Chapter 4).
Make Sure that the packer o-ring and discharge o-ring seal
surfaces are clean.
Confirm length of pump prior to installation.
Do not damage the surface above the discharge port. The
o-ring below the leak detector port seals on this surface.
2:
Attach the UMP (see “Attaching the UMP” in Chapter 2)
3:
Measure the distance from the bottom of the tank to the sealing surface of the
manifold.
NOTICE
DANGER
DANGER
NOTICE
CAUTION
Summary of Contents for Red Jacket AGUMP33R1
Page 14: ...8 4 Petroleum AG...