61
<oid-string> {include|exclude}
no snmp-server view <view-string>
command is used for SNMP v3.
8.
Configuring TRAP
Command
Explanation
snmp-server enable traps
no snmp-server enable traps
Enable the switch to send Trap message.
This command is used for SNMP v1/v2/v3.
snmp-server host <host-address >
{v1|v2c|{v3
{NoauthNopriv|AuthNopriv|AuthPriv}}}
<user-string>
no snmp-server host <host-address>
{v1|v2c|{v3 {NoauthNopriv|AuthNopriv
|AuthPriv}}} <user-string>
Set the host IP address which is used to
receive SNMP Trap information. For SNMP
v1/v2, this command also configures Trap
community string; for SNMP v3, this
command also configures Trap user name
and security level.
9.
Enable/Disable RMON
Command
Explanation
rmon enable
no rmon enable
Enable/disable RMON.
2.4.4.2 SNMP Configuration Commands
2.4.4.2.1
snmp-server
Command: snmp-server
no snmp-server
Function:
Enable the SNMP agent server function on the switch; the “
no snmp-server
enable”
command disables the SNMP agent server function
.
Command mode:
Global Mode
Default:
SNMP agent server function is disabled by default.
Usage Guide:
To enable configuration and management via network administrative
software, this command must be executed to enable the SNMP agent server function on
the switch.
Example:
Enable SNMP Agent server function on the switch.
Switch(Config)#snmp-server
Summary of Contents for ES4626
Page 1: ...1 ES4626 ES4650 Layer 3 Gigabit Switch Management Guide www edge core com...
Page 122: ...122...
Page 209: ...209...