39
IE1-1230-B
February 2001
Group 0 Option 3 Assistance Channel
The engineer can assign any zone as an Assistance Channel. This option when enabled
will overide any chosen Group 8 Option.
0. Disabled
1. Overide report Fire to ARC
2. Overide report PA channel to ARC
3. Overide report Alarm channel to ARC
4. Overide report Set/Unset channel to ARC
5. Overide report Day Tamper channel to ARC
6. Overide report RF Low Battery channel to ARC
7. Overide report Abort channel to ARC
8
Overide report Verify Alarm channel to ARC
This option defaults to 0 (Disabled).
Note:
The function of Assistance Channel depends upon the relevant Group 8 Option
being enabled.