9
IE1-1230-B
February 2001
Fitting the Tamper Switch
The Accord xpC enclosure is supplied without a Tamper Actuator in place. The panel
will not function without a Tamper, it is therefore, the installers responsibility to correctly
attach the Tamper Actuator. The Tamper Actuator consists of a spring, which is supplied
in the Accord xpC Installation Kit, and one of the Knockout Tamper Posts, see
figure
2.1.
The installer should knockout one of these Tamper Posts from the enclosure base and
ensure the spring is securely attached to the short end of the Tamper Post, before fitting
the opposite end of the spring to the Tamper Switch (SW1) on the PCB (see below).
1 Amp
0.5 Amp
0.5 Amp
AUX
KP
AD
TRIG
LS
1
5
AC
AC
BA
TTER
Y
+
1
4
A
B
PHONE
EE Volume
+
VADJ
SW 1
BELL
STRB
BTMP
ZONE
TAMP
1
ZONE
2
ZONE
7
ZONE
6
ZONE
5
ZONE
4
ZONE
3
ZONE
8
ZONE
BELL
AUX
BA
TT
T1
RL1
S1
X1
IC12
1
5
LED
+ _
_
_
R
Tamper
Post
Tamper
Spring
Fit Tamper to SW1