28
s
g
n
i
R
f
o
o
N
n
o
i
t
a
r
e
p
O
l
e
n
a
P
0
0
.
s
ll
a
c
g
n
i
m
o
c
n
i
s
r
e
w
s
n
a
r
e
v
e
n
l
e
n
a
P
4
1
–
1
0
e
h
t
e
r
o
f
e
b
s
g
n
i
r
f
o
r
e
b
m
u
n
e
h
t
s
l
a
u
q
e
y
r
t
n
E
.
s
r
e
w
s
n
a
l
e
n
a
p
5
1
.
t
a
e
f
e
d
e
n
i
h
c
a
m
r
e
w
s
n
A
Table 3.11 No of Rings
Call Back:
The call is initiated from the PC. The panel answers and the PC
establishes that the correct Downloader ID is present. The panel hangs up and calls
the Downloader Telephone No. Remote servicing may begin when the PC answers
and a correct Downloader ID is confirmed.
Wait for Call:
Enter a valid user code at a keypad, press the # key then 1 to initiate
dialling of the Downloader Telephone No. Remote servicing may begin when the
PC answers and a correct Downloader ID is confirmed.
Dial Site:
The call is initiated from the PC. The panel answers and checks the
programmed Account No and Downloader ID. If correct, a valid link is established
and remote servicing may begin.
Note: This option cannot be used if downloader telephone number is programmed.
Access to the system via the Downloader software is subject to menu option
Group 7 Option 8 Downloader Options.
Group 6 Option 5 Downloader Telephone Number.
A Downloader Telephone Number of up to 20 digits may be entered. If less than 20 digits
are used, end programming by pressing the
Ö
key.
This option should only be programmed if the Ademco Microtech Windows Downloader
software is to be used with the panel. The Ademco Microtech Windows Downloader is a
software programme that allows remote servicing of the Accord xpC panel, including
programme/event-log uploading and downloading. The Ademco Microtech Windows
Downloader software runs on an IBM compatible PC running Microsoft Windows 3.0,
3.1, 95 or 98.
The Downloader software must be operated in one of three modes:
Group 6 Option 6 Downloader I.D. Number
This option specifies a eight digit I.D. number for panels communicating via the
Downloader Software.
This option defaults to 99999999.
Group 6 Option 7 Ring Count
This option determines how many times the telephone line rings before the panel
picks up. The programmable range of 00 to 15 is outlined in
Table 3.11
.
If set to answer machine defeat (15) the Accord xpC only picks up the line if the download
PC dials in, hangs up after one ring then redials.
This option defaults to 14 rings (14).
Summary of Contents for XPC
Page 1: ...i Installation Manual...
Page 2: ...ii...
Page 12: ...6...
Page 22: ...16...
Page 56: ...50...
Page 61: ...55 IE1 1230 B February 2001...
Page 62: ...56 IE1 1230 B...