background image

www.acclima.com   DataSnap/SnapView

 

User Manual

 

13 

Acclima has engineered a more efficient and intelligent way to configure multiple Acclima sensors simultaneously. This significantly 

simplifies the configuration process and is done using the ‘Add Acclima Sensors’ option.

 

 
Add Acclima Sensors 
To add one or more Acclima sensors to the DataSnap: 

 

Wire each Acclima sensor to the DataSnap as described in the ‘Wiring Sensors to the SDI

-

12 Port’ section earlier in this 

document 

 

Click the ‘Add Acclima Sensors’ button

 

 

Each Acclima sensor will be automatically detected and added to the DataSnap. Each newly added sensor will be configured 
with a set of default properties. These can be changed at any time. This is addressed later in this document.  

 
Add a Single Sensor 
To add a single, non-Acclima sensor to the DataSnap: 

 

Physically disconnect the wires of all existing sensors from the DataSnap 

 

Wire the new sensor to the DataSnap as described in the ‘Wiring Sensors to the SDI

-

12 Port’ section earlier in this 

document 

 

Click the ‘Add a Single Sensor’ button

 

 

The sensor is detected automatically and added to the DataSnap. The newly added sensor will be configured with a set of 
default properties. These can be changed at any time. 

 
The DataSnap does not support duplicate serial numbers. If there are one or more sensors with the same serial number, the sensor 
that was configured last will be used. 
 
Modifying Sensor Settings 
Each sensor has its own unique set of reading descriptions which can be modified. This includes a descriptive sensor name and 
descriptive names for each of the 5 reading

s. To modify sensor settings, click on the sensor in the ‘Configured Sensors’ list. Details 

for the selected sensor will be displayed. Make any desired changes and click the ‘Save’ button.

 

 
When a sensor is added, its reading descriptions are automatically set based on the defaults for this type of sensor. These default 

reading descriptions can be modified or removed using the ‘Manage Reading Descriptions’ screen in the Tools menu. If there ar

e no 

defaults for a particular sensor type, SnapView can automatically create them. This occurs the first time a user enters reading 

descriptions on the ‘Sensor Details’ window and clicks ‘Save’.

 

  
There may be times when it is necessary to remove a configured sensor since it is no longer needed or to make room for a new 

sensor. This is easily done by clicking the ‘Remove Sensor from DataSnap’ button at the top of the ‘Sensor Details’ window. T

his does 

not remove any data from the PC, it only removes it from the configuration on the DataSnap. 
 

 

Figure 12 - Adding Sensors 

Summary of Contents for ACC-AGR-D01

Page 1: ...DataSnap User Manual SDI 12 Data Recorder Part Number ACC AGR D01...

Page 2: ...Up a New System 7 Selecting Acclima Moisture Sensor Locations 8 Installing Acclima Moisture Sensors 8 Wiring Sensors to the SDI 12 port 8 Using Acclima SnapView Software 10 Configuration 10 Automatic...

Page 3: ...aSnap 2 pluggable terminal blocks for the SDI 12 connection USB cable type A B AC power adapter 12V DC battery power pack Installation CD with SnapView software and driver Supported Sensors The Acclim...

Page 4: ...can be unplugged from the DataSnap while wiring sensors together Multiple sensors can be wired in parallel to the same SDI 12 port External Power Port This connection is provided should the sensor ne...

Page 5: ...via a USB cable Windows will automatically detect the new Data Snap hardware and will attempt to find the appropriate driver This driver installation process will only occur once per Data Snap Each n...

Page 6: ...because the driver was installed to this location when the SnapView software was installed Figure 3 Once the driver is found and installed the Data Snap will be assigned to a port and will be availabl...

Page 7: ...aSnap Each newly added sensor is configured with a set of default properties that can be changed at any time This is addressed later in this document Add non Acclima Sensors Each non Acclima sensor mu...

Page 8: ...ort soil moisture as a percentage of the total volume measured This means that the measured volume of soil should be free of foreign objects or variations that may alter the measurement made by the se...

Page 9: ...res to a separate single wire and then connecting the single new wire to the terminal block in the appropriate position Follow the same procedure to connect the white and blue wires The wiring should...

Page 10: ...top of the screen This will display the Configuration wizard The SDI 12 protocol requires that a sensor be given a specific address All communication with a sensor is based on this address When a sen...

Page 11: ...ormed on the connected DataSnap Click the Refresh List button to scan the computer for DataSnaps and update the connection list System Configuration Settings The system configuration screen allows mod...

Page 12: ...It is not limited to Acclima sensors The DataSnap must be configured to know which sensors to read This is done by adding sensors in the Sensors screen The current list of configured sensors is displ...

Page 13: ...e can be changed at any time The DataSnap does not support duplicate serial numbers If there are one or more sensors with the same serial number the sensor that was configured last will be used Modify...

Page 14: ...en Hovering the mouse over the icon displays the number of logs that still need to be retrieved from the DataSnap as shown in figure 18 If one or more DataSnaps are connected via a USB port the SnapVi...

Page 15: ...p s name To expand collapse the list of sensors click the gray circle or click the DataSnap s name Individual sensors can be selected deselected by clicking the checkmark next to the sensor name Figur...

Page 16: ...to be easily pasted into any Windows application View Graphs Sensor readings for all sensors can be viewed visually through the Graph screen To see the Graph screen click on the Graph button at the t...

Page 17: ...right will change the displayed start date in the main graph to a later date The right most range indicator behaves similarly and effects the end date on the main graph The selected date range is dis...

Page 18: ...e viewed by selecting the Errors in the list to the left Errors are displayed in a separate grid When both grids are displayed the grid size can be adjusted To do this hover the cursor over the horizo...

Page 19: ...can be selected or not selected as desired If an item is selected it will be displayed in the grid If it is not selected it will be hidden in the grid To select all items click the Select All option...

Page 20: ...Field Test Only data between 5am on January 16 2012 and 9 30pm on January 23 2012 will be exported The output file will be named myDataSnapExport csv and will be saved in the C data folder Tools The t...

Page 21: ...eric COM port on that computer This COM port should be visible in Device Manager as Acclima Virtual COM port The communications settings for this COM port are unimportant and can be ignored since the...

Page 22: ...22 2015 2017 Acclima Inc Toll Free 1 866 887 1470 Acclima Inc 1763 West Marcon Lane Ste 175 Meridian ID 83642 USA www acclima com...

Reviews: