INNOVATIONS TO ENABLE LONG RUNS

There are numerous challenges involved with creating long runs of high output LED fixtures, 
most notably concerning control and power; in response, Acclaim Lighting engineers have 
created ingenious solutions to ensure consistent and reliable operation:

CONTROL

Long distances and high fixture counts are detrimental even to such a robust control 
solution as DMX; usually a maximum of 32 fixtures is possible before the signal-to-noise ratio 
threatens to affect operation. That is why Terra Drum fixtures act as their own signal isolator 
and conditioner before passing the control feed down the line. The result is a clean, reliable 
and [still] industry-standard control solution right to the end of the line. Additionally, as each 
fixture supports RDM, the passage of conditioned and isolated signals is fully bi-directional.    

POWER 

Every Terra Drum fixture conditions its own power using a high-efficiency internal switched-
mode power supply. A well known feature of such devices is their behavior during the 
fractions of a second after power is first applied, known as ‘in-rush current’. This is when their 
internal components top themselves up with charge to progress from empty to a working 
state, which causes a very brief rise above their usual maximum consumption level. If you 
place many such devices on the same power line and activate them all simultaneously, their 
collective temporary overruns can easily swamp an otherwise perfectly adequate power 
feed, causing breaker trips.
To reliably solve this issue, the common high voltage power rail running through the supply 
cables is not a ‘dumb run’ but rather a managed resource. Every fixture energizes itself fully 
before passing power through to the next fixture in the chain. The delay at each fixture is 
measured in milliseconds, but it is sufficient to ensure that the installation as a whole never 
stresses the main power feed during the initial startup.     

Summary of Contents for Terra Drum

Page 1: ...User guide Terra Drum 15 10 5 0 5 10 15 15 10 5 0 5 10 15...

Page 2: ......

Page 3: ...3 Interconnecting 14 Termination 14 Optional AJBOX1 conduit connections 15 Run lengths fixture maximum 16 Run lengths overall maximum 16 Important cabling considerations 17 Control 18 Tips for achievi...

Page 4: ...industry standard DMX 512A format with RDM for configuration DALI and 0 10V control inputs can also be used when optional converters are employed SAFETY Terra Drum fixtures should not be recessed into...

Page 5: ...ACCESSORIES Terra Drum HO SO or EO Feed cables incl terminator end cap 10 3m TLAFC10 50 15m TLAFC50 In ground sleeve plus removable pour cover HO TDAIGS SO TDBIGS EO TDCIGS continued For dimensions o...

Page 6: ...0 Link cables 1 30cm TLALC1 5 1 5m TLALC5 10 3m TLALC10 Terminator end cap TLATEC Full snoots HO SO EO Black TDAFSB TDBFSB TDCFSB White TDAFSW TDBFSW TDCFSW Gray TDAFSG TDBFSG TDCFSG Custom TDAFSC TDB...

Page 7: ...uts as well as an acrylic pour cover for the upper surface which fully protects the internal chamber while surface work is in progress IMPORTANT To achieve a full 6000 lbs 2 721kg drive over rating th...

Page 8: ...as a permeable stone gravel mix If the base is concrete then suitable drainage holes should be created DRAINAGE RATE A minimum drainage rate of 0 022 gallons per minute 0 1 liters per minute should be...

Page 9: ...For walk and drive over installations the sides of the sleeve must be fully supported and the sleeve height must be arranged to ensure that its top edge is exactly level with the finished surface Slee...

Page 10: ...or the final fixing screws and also for making fine tilt adjustments to the head angle once the fixture is in place TO INSTALL A TERRA DRUM FIXTURE 1 Prepare the mounting location s see Mounting on pa...

Page 11: ...nduit lock nut 5 Run the link cable s through the conduit s into the sleeve chamber using a draw wire if necessary 6 If possible test the connections before the final surface is laid 7 Prior to surfac...

Page 12: ...ration Failure to do so may invalidate the warranty See page 14 15 10 5 0 5 10 15 10 Carefully fold the cables into the chamber as the Terra Drum is lowered Note It is a tight fit particularly on the...

Page 13: ...at least its axis is pointing towards the object to be illuminated 15 10 5 0 5 10 15 ILLUMINATED SURFACE Marker arrow 12 Place the supplied trim ring onto the Terra Drum top face and align its three b...

Page 14: ...ty driver not supplied to loosen the bung on the glass surface of the fixture Once loosened prise out the bung and set aside 15 10 5 0 5 10 15 15 10 5 0 5 10 15 The indicator will show the level of in...

Page 15: ...ns supply At each connection remove the cover caps from both the socket and plug Align the orientation marks of the socket and plug then push them together and twist the locking collar to lock them fu...

Page 16: ...l link cable can be used between any two fixtures to make up a gap To next fixture Feed cable link cable or output from previous fixture Orientation keys marks TERMINATION It is important that the fin...

Page 17: ...le connections should be arranged on the internal connector blocks as shown here The separate power and control input connections can be made on the other side of these connector blocks IMPORTANT The...

Page 18: ...tures in a single run as discussed above you also need to adhere to the working limits for the overall length of the whole installation ie the total length fixtures in the run plus all their additiona...

Page 19: ...AWG minimum Additional DMX control cabling For initial control runs leading to the Terra Drum cabling these cables or direct equivalents are recommended Indoor exposed or inside conduit above grade B...

Page 20: ...e an Acclaim Lighting DDC 1 AC or similar to convert one or more DALI channels into a combined DMX feed NOTES When using Acclaim Lighting ZDM 6 or DDC 1 AC modules it is possible to convert up to six...

Page 21: ...plit into the control cabling If it is necessary to split the control link in order feed fixtures located in different directions use a powered DMX splitter such as the Acclaim Lighting RDS 6 https ac...

Page 22: ...ignal to a Terra Drum run over distances up to 2600 feet 792m For further details please see Acclaim Lighting Aria Wireless user guide Tx 0 10V IN ZDM 6 OPTIONAL WIRELESS 0 10V CONTROL Add an Acclaim...

Page 23: ...ER Every Terra Drum fixture conditions its own power using a high efficiency internal switched mode power supply A well known feature of such devices is their behavior during the fractions of a second...

Page 24: ...IN TERRA DRUM HO TERRA DRUM HO TERRA DRUM HO 005 009 012 PATCH OPTIONS 004 004 RESTART PATCHING MAIN TERRA DRUM HO TERRA DRUM HO TERRA DRUM HO 005 009 012 PATCH OPTIONS 004 004 TERRA DRUM HO 001 4 On...

Page 25: ...l emitters equally TO CHECK EMITTERS USING INTERNAL TEST MODES You can also optionally check operation using either of two internal test modes 1 Connect an XMT 350 to the DMX input line of the Terra D...

Page 26: ...to full output until the control signal is restored If power is cycled while the control signal is absent each fixture will remain at full until the signal is restored Dynamic white RGBW and RGBA vers...

Page 27: ...an RDM tool to perform an emitter test Check that the DMX address set within the fixture matches that being output by the controlling source device Check the DMX output near to the source to confirm...

Page 28: ...cm lengths with IP68 multi pin connectors Mounting In ground sleeve required ordered separately Includes pour cover and knock outs for 1 5 conduit Material Anodized aluminum with marine grade coating...

Page 29: ...27 www acclaimlighting com TERRA DRUM HO DIMENSIONS 12 36 314mm 7 48 190mm 1 3 33mm 0 16 4mm 0 16 4mm 0 87 22mm 9 72 247mm 11 14 283mm...

Page 30: ...28 www acclaimlighting com 9 53 242mm 7 24 184mm 1 54 39mm 0 16 4mm 0 63 16mm 9 63 176mm 8 15 207mm 0 16 4mm TERRA DRUM SO...

Page 31: ...29 www acclaimlighting com 7 24 184mm 1 14 29mm 0 16 4mm 0 57 14 5mm 5 28 134mm 5 98 152mm 7 13 181mm 0 16 4mm TERRA DRUM EO...

Page 32: ...30 www acclaimlighting com 1 85 47mm 8 46 215mm 7 01 178mm 0 16 4mm 12 36 314mm HO SLEEVE OD 12 28 312mm OD 12 28 312mm 5 91 150mm 5 91 150mm HO SNOOTS...

Page 33: ...31 www acclaimlighting com SO SLEEVE 1 85 47mm 0 16 4mm 9 53 242mm 8 46 215mm 7 01 178mm OD 9 84 240mm OD 9 45 240mm 3 94 100mm 3 94 100mm SO SNOOTS...

Page 34: ...32 www acclaimlighting com EO SLEEVE 1 85 47mm 8 46 215mm 7 01 178mm 0 16 4mm 7 13 181mm OD 7 09 180mm OD 7 09 180mm 3 54 90mm 3 54 90mm EO SNOOTS...

Page 35: ...33 www acclaimlighting com CABLES Feed cable 10 or 50 Link cable 1 5 or 10 Terminator end cap...

Page 36: ...34 www acclaimlighting com AJBOX1 1 No NPT conduit outlet 2 No NPT conduit inlets 2 No NPT conduit inlets...

Page 37: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 38: ...www acclaimlighting com...

Reviews: