background image

23

www.acclaimlighting.com

TESTING FIXTURES

After you have addressed each Terra Drum fixture we recommend that you also test each 
one prior to installation. This can be achieved with your RDM (Remote Device Management) 
tool. Various third party DMX/RDM tools are available; we recommend the Acclaim Lighting 
XMT-350 for this task.

TO TEST OPERATION USING THE ACCLAIM LIGHTING XMT-350

1  Connect an XMT-350 to the DMX input line of either a single fixture or multiple fixtures in 

a pre-arranged daisy chain configuration.

2  Power on the fixture(s) and the XMT-350.
3  On the XMT-350, press the 

MODE

 button, then use 

the arrow buttons to highlight the 

SEND

 function and 

press the   button to select. 

4  Use the arrow buttons to determine the DMX output:

 

Use the left and right buttons to choose the DMX 
address,

 

Use the up and down buttons to increase/
decrease the level at the chosen address. 

Note: If you wish to send DMX values to all addresses simultaneously (rather than cycling 
through them individually), when the XMT-350 is showing address 001, press the left button 
once to change to 

ALL CHANNELS

. Now when you set the level it will affect all emitters equally.

 

TO CHECK EMITTERS USING INTERNAL TEST MODES

You can also optionally check operation using either of two internal test modes.
1  Connect an XMT-350 to the DMX input line of the Terra Drum installation.
2  On the XMT-350, press the 

MODE

 button, then use the arrow buttons to highlight the 

RDM

 function and press the   button to select. The XMT-350 will search for RDM devices 

and after a short while the XMT-350 will display a list of all located fixtures. The fixture 
highlighted in the list will flash its emitters to identify itself.

3  If necessary, use the up/down buttons to highlight an alternative fixture. 
4  Press the   button to view details for the chosen 

fixture and then use the down button to highlight 
the 

DMX PERSONALITY

 entry:

5  Press the    button to view the options:

 

For a color (or dimmed white) chase, choose 

PROGRAM TEST

,

 

For 100% static output on all emitters, choose  

FULL OUTPUT TEST

.

  

6  Highlight the required test mode and press the    button to select. 
7  Press the   button to return to the previous screen and then exit the RDM function 

completely to allow the fixture to respond.

Note: To end the test, go back to the 

DMX PERSONALITY

 option and choose the original 

configuration setting, eg RGBW.

  

TERRA DRUM HO

MODEL:

TERRA DRUM HO

MAN:

DMX START ADDRESS:

DMX SLOTS:

ACCLAIM

001

4

LABEL:

TERRA DRUM HO

DMX PERSONALITY:

RGBW

Summary of Contents for Terra Drum

Page 1: ...User guide Terra Drum 15 10 5 0 5 10 15 15 10 5 0 5 10 15...

Page 2: ......

Page 3: ...3 Interconnecting 14 Termination 14 Optional AJBOX1 conduit connections 15 Run lengths fixture maximum 16 Run lengths overall maximum 16 Important cabling considerations 17 Control 18 Tips for achievi...

Page 4: ...industry standard DMX 512A format with RDM for configuration DALI and 0 10V control inputs can also be used when optional converters are employed SAFETY Terra Drum fixtures should not be recessed into...

Page 5: ...ACCESSORIES Terra Drum HO SO or EO Feed cables incl terminator end cap 10 3m TLAFC10 50 15m TLAFC50 In ground sleeve plus removable pour cover HO TDAIGS SO TDBIGS EO TDCIGS continued For dimensions o...

Page 6: ...0 Link cables 1 30cm TLALC1 5 1 5m TLALC5 10 3m TLALC10 Terminator end cap TLATEC Full snoots HO SO EO Black TDAFSB TDBFSB TDCFSB White TDAFSW TDBFSW TDCFSW Gray TDAFSG TDBFSG TDCFSG Custom TDAFSC TDB...

Page 7: ...uts as well as an acrylic pour cover for the upper surface which fully protects the internal chamber while surface work is in progress IMPORTANT To achieve a full 6000 lbs 2 721kg drive over rating th...

Page 8: ...as a permeable stone gravel mix If the base is concrete then suitable drainage holes should be created DRAINAGE RATE A minimum drainage rate of 0 022 gallons per minute 0 1 liters per minute should be...

Page 9: ...For walk and drive over installations the sides of the sleeve must be fully supported and the sleeve height must be arranged to ensure that its top edge is exactly level with the finished surface Slee...

Page 10: ...or the final fixing screws and also for making fine tilt adjustments to the head angle once the fixture is in place TO INSTALL A TERRA DRUM FIXTURE 1 Prepare the mounting location s see Mounting on pa...

Page 11: ...nduit lock nut 5 Run the link cable s through the conduit s into the sleeve chamber using a draw wire if necessary 6 If possible test the connections before the final surface is laid 7 Prior to surfac...

Page 12: ...ration Failure to do so may invalidate the warranty See page 14 15 10 5 0 5 10 15 10 Carefully fold the cables into the chamber as the Terra Drum is lowered Note It is a tight fit particularly on the...

Page 13: ...at least its axis is pointing towards the object to be illuminated 15 10 5 0 5 10 15 ILLUMINATED SURFACE Marker arrow 12 Place the supplied trim ring onto the Terra Drum top face and align its three b...

Page 14: ...ty driver not supplied to loosen the bung on the glass surface of the fixture Once loosened prise out the bung and set aside 15 10 5 0 5 10 15 15 10 5 0 5 10 15 The indicator will show the level of in...

Page 15: ...ns supply At each connection remove the cover caps from both the socket and plug Align the orientation marks of the socket and plug then push them together and twist the locking collar to lock them fu...

Page 16: ...l link cable can be used between any two fixtures to make up a gap To next fixture Feed cable link cable or output from previous fixture Orientation keys marks TERMINATION It is important that the fin...

Page 17: ...le connections should be arranged on the internal connector blocks as shown here The separate power and control input connections can be made on the other side of these connector blocks IMPORTANT The...

Page 18: ...tures in a single run as discussed above you also need to adhere to the working limits for the overall length of the whole installation ie the total length fixtures in the run plus all their additiona...

Page 19: ...AWG minimum Additional DMX control cabling For initial control runs leading to the Terra Drum cabling these cables or direct equivalents are recommended Indoor exposed or inside conduit above grade B...

Page 20: ...e an Acclaim Lighting DDC 1 AC or similar to convert one or more DALI channels into a combined DMX feed NOTES When using Acclaim Lighting ZDM 6 or DDC 1 AC modules it is possible to convert up to six...

Page 21: ...plit into the control cabling If it is necessary to split the control link in order feed fixtures located in different directions use a powered DMX splitter such as the Acclaim Lighting RDS 6 https ac...

Page 22: ...ignal to a Terra Drum run over distances up to 2600 feet 792m For further details please see Acclaim Lighting Aria Wireless user guide Tx 0 10V IN ZDM 6 OPTIONAL WIRELESS 0 10V CONTROL Add an Acclaim...

Page 23: ...ER Every Terra Drum fixture conditions its own power using a high efficiency internal switched mode power supply A well known feature of such devices is their behavior during the fractions of a second...

Page 24: ...IN TERRA DRUM HO TERRA DRUM HO TERRA DRUM HO 005 009 012 PATCH OPTIONS 004 004 RESTART PATCHING MAIN TERRA DRUM HO TERRA DRUM HO TERRA DRUM HO 005 009 012 PATCH OPTIONS 004 004 TERRA DRUM HO 001 4 On...

Page 25: ...l emitters equally TO CHECK EMITTERS USING INTERNAL TEST MODES You can also optionally check operation using either of two internal test modes 1 Connect an XMT 350 to the DMX input line of the Terra D...

Page 26: ...to full output until the control signal is restored If power is cycled while the control signal is absent each fixture will remain at full until the signal is restored Dynamic white RGBW and RGBA vers...

Page 27: ...an RDM tool to perform an emitter test Check that the DMX address set within the fixture matches that being output by the controlling source device Check the DMX output near to the source to confirm...

Page 28: ...cm lengths with IP68 multi pin connectors Mounting In ground sleeve required ordered separately Includes pour cover and knock outs for 1 5 conduit Material Anodized aluminum with marine grade coating...

Page 29: ...27 www acclaimlighting com TERRA DRUM HO DIMENSIONS 12 36 314mm 7 48 190mm 1 3 33mm 0 16 4mm 0 16 4mm 0 87 22mm 9 72 247mm 11 14 283mm...

Page 30: ...28 www acclaimlighting com 9 53 242mm 7 24 184mm 1 54 39mm 0 16 4mm 0 63 16mm 9 63 176mm 8 15 207mm 0 16 4mm TERRA DRUM SO...

Page 31: ...29 www acclaimlighting com 7 24 184mm 1 14 29mm 0 16 4mm 0 57 14 5mm 5 28 134mm 5 98 152mm 7 13 181mm 0 16 4mm TERRA DRUM EO...

Page 32: ...30 www acclaimlighting com 1 85 47mm 8 46 215mm 7 01 178mm 0 16 4mm 12 36 314mm HO SLEEVE OD 12 28 312mm OD 12 28 312mm 5 91 150mm 5 91 150mm HO SNOOTS...

Page 33: ...31 www acclaimlighting com SO SLEEVE 1 85 47mm 0 16 4mm 9 53 242mm 8 46 215mm 7 01 178mm OD 9 84 240mm OD 9 45 240mm 3 94 100mm 3 94 100mm SO SNOOTS...

Page 34: ...32 www acclaimlighting com EO SLEEVE 1 85 47mm 8 46 215mm 7 01 178mm 0 16 4mm 7 13 181mm OD 7 09 180mm OD 7 09 180mm 3 54 90mm 3 54 90mm EO SNOOTS...

Page 35: ...33 www acclaimlighting com CABLES Feed cable 10 or 50 Link cable 1 5 or 10 Terminator end cap...

Page 36: ...34 www acclaimlighting com AJBOX1 1 No NPT conduit outlet 2 No NPT conduit inlets 2 No NPT conduit inlets...

Page 37: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 38: ...www acclaimlighting com...