11
www.acclaimlighting.com
Ethernet input
and thru ports
Note: A maximum cable size of 12 AWG
(4mm
2
) can be used directly within the
terminal block contacts.
1
2
3
Eth
ern
et
Th
ru
Po
we
r 2
00W
Ma
x
Power/signal GND
Signal data output
No connection
+24VDC
PIXEL DRIVER 400 CONNECTIONS
Each Pixel Driver 400 unit accepts an Art-Net control input via Ethernet and provides an
Ethernet Thru port to allow multiple units to be directly daisy-chained. Each unit has eight
SPI outputs labeled 1 to 8 to which Flex Tube Pixel strips can be directly connected. The
eight ports are powered in two groups: ports 1 to 4 and ports 5 to 8.
In each group of four output ports, ensure the total power draw
does not exceed 200W (8.3A). Flex Tube Pixel strips have the
following power requirements: 6.7W per foot (22W per
meter).
SPI output ports
1 to 8