POWER AND CONTROL WIRING
AL Dot fixtures use Chogori™ Standard (22) series IP67 5-pin
connectors for their combined power/control inputs and
outputs. AL Dot fixtures can be either daisy chained directly
to each other or via intermediary link cables, depending on
distances between fixtures.
AL Dot fixtures require both a regulated 24VDC power input as
well as DMX control. The final fixture in the line should have a
120Ω terminating resistor connected between the DMX + and
DMX – lines.
Due to the limited current carrying capacity of the internal
power buses, runs of AL Dot fixtures must not exceed 100 feet
(30m). See page 8 if longer runs are needed.
The required feed cables (available as separate purchase)
also include (male plus matching female) pluggable
terminal sockets (5.08mm pitch) at the external end for rapid
connections. The cable designations are as follows:
Connections to
feed cables are best
protected within
junction boxes with
suitable IP ratings
AL Dot
3’ (10m)
feed-in cable
24VDC and DMX
[Part #: ADOFC10]
Chogori™
22 series
5-pin
Signal
Ground
DMX+
DMX–
24VDC
Power
Ground
Female connector
pin-out
IMPORTANT: These connectors are not rated for live connection or disconnection.
Check that power is isolated before making or breaking any links. Ensure the
connectors have locked and are seated correctly before applying power.
Note: Acclaim requires Belden 9842
or approved equivalent for all DMX
wiring applications.