4
VITAL Installation and User Guide
FUNCTIONAL SPECIFICATIONS
VITAL is a versatile solution to track any powered asset. Each input can be customized
based on the asset being monitored so reports can provide data in the context of how
the asset is maintained.
Electrical
Voltage Input
12-80 VDC
Current
50 mA (Typical) 150 mA (Peak)
Communication
Wi-Fi (WPA2 - PSK) Cellular (GSM, 3G/2G)
Location Tracking
GPS, Cell Assist
Inputs
4 (12-80 VDC)
Active High or Low (Programmable)
Output
Relay, NO (Optional)
Mechanical and Environmental
Dimensions
5 X 3 X 1.25 (in inches)
Mounting
#10 or M4 Screws (2) - Included
Temperature
Operating: -20 - 70 Deg C
Storage: -20 - 80 Deg C
Humidity
97%, Non-condensing
Sealing
IP65