2015.04.16
Flow2 - Stairlift
Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.com
Error code
F41
Error message
Opto failure ELD
Description
Defective opto emergency lowering device
Safety action
Normal stop
Possible solution
Replace opto
Error suppressed in
Mode -3-
Error code
F42
Error message
Opto failure swivel zero
Description
Defective opto swivel zero
Safety action
Normal stop
Possible solution
Replace opto
Error suppressed in
Mode -3- / ELD mode
Error code
F47
Error message
Opto failure squeeze
Description
Defective squeeze opto
Safety action
Normal stop
Possible solution
Replace opto
Error suppressed in
Mode -3- / ELD mode
Error code
F49
Error message
Receiver board failure
Description
Defective receiver board
Safety action
Normal stop
Possible solution
-
Check cable and connections and receiverboard version.
Replace if damaged.
-
Replace receiver board
Error suppressed in
Mode -3- / ELD mode
Error code
F50
Error message
Parameters corrupt
Description
Failed to read parameters (motor control or application)
Safety action
Normal stop
Possible solution
Reboot / Mode -9- CLR,
please note to backup your raildata
.
Error suppressed in
Mode -3-
Error code
F51
Error message
Rail data corrupt
Description
For example: less than 2 halt positions or speed entries programmed
Safety action
Normal stop
Possible solution
Program correctly or restore by Mode -9- (RES)
Error suppressed in
Mode -3- / ELD mode
Error code
F52
Error message
Drive position unknown
Description
Reset point not “seen” (yet).
Safety action
Normal stop
Possible solution
Drive to reset point in mode -3-
Error suppressed in
Mode -3- / ELD mode