2015.04.16
Flow2 - Stairlift
Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.com
Warning code
C70
Warning message
Test run required
Description
Lift has not made a full trip yet.
Safety action
Report the warning
Possible solution
Make full test run.
Warning suppressed in
Mode -3- / ELD mode
Warning code
C71
Warning message
Test user emergency stop required
Description
Switches in UI must be tested on correct functioning.
Safety action
Report the warning
Possible solution
Remove joystick from UI and re-insert.
Warning suppressed in
Mode -3- / ELD mode
Warning code
C73
Warning message
Position outside programmed rail data
Description
Safety action
Report the warning
Possible solution
Programm correctly
Warning suppressed in
Mode -3- / ELD mode
Warning code
C80
Warning message
Main motor temp. high
Description
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C81
Warning message
Level motor temp. high
Description
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C85
Warning message
Backup battery low warning
Description
The backup battery falls below 1,65V
Safety action
Report the warning
Possible solution
Replace battery
Warning suppressed in
-
Warning code
C86
Warning message
Level deviation warning
Description
Deviation between level sensors > 4°
Safety action
Reduce speed
Possible solution
-
Reduce speed at point of occurrence
-
Recalibrate level sensors
-
Replace sensor board(s)
Warning suppressed in
Mode -3-