-31-
BURNER AND PILOT SYSTEM
The burner assembly may be removed for easier access to the
control compartment.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Vacuum all components of the burner system.
• Visually check burner ports for blockage, especially near the pilot.
•
Visually check pilot light and burner flame pattern when in
operation. Flames should be steady, not lifting or floating.
FAN
Performed by:
Qualified Service Person
Frequency:
Every 6 months
Action:
• Disconnect the fans from electrical current and vacuum.
• The bearings are sealed and require no oiling.
VENT SYSTEM
NOTE: If the vent-air intake system is disassembled for any reason, reinstall per instructions provided with installation
(see Installation section).
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Examination of the vent system is required.
•
The flow of combustion and ventilation air must not be obstructed.
GLASS ASSEMBLY
Burner Ports
Burner And Pilot System
Burner Orifice
Breakout View For
Clarification Purposes Only
WARNING: The fireplace area must be kept clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
CAUTION: Do not operate with the glass assembly removed, cracked, or broken. Use protective gloves to
handle any broken or damaged glass assembly components.
WARNING: Do not use substitute materials. Avoid striking or slamming glass assembly. Avoid abrasive cleaner.
DO NOT clean glass while it is hot.
CAUTION: Any safety screen, guard, or barrier removed for servicing must be replaced prior to operating.
Performed by:
Homeowner
Frequency:
Annually
Action:
•
Prepare a work area large enough to accommodate the glass assembly on a flat, stable surface.
• Remove safety screen and glass frame assembly.
• Clean glass with a soft cloth and a non-abrasive cleaner.
• Reinstall glass assembly and safety screen.
•
Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating
the appliance.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Inspect the glass for cracks, scratches, and nicks.
• Verify the glass assembly is properly intact and not damaged.
• Replace the glass and the assembly as necessary.
• Only Ashley will supply the replacement of glass assembly as a complete unit.