Technical Information
ƶƱ
Step
Procedure
7. Remove electric box assy
a. Loosen the connection clasps between
shield cover of electric box sub-assy and
electric box, and then remove the shield
cover of electric box sub-assy.
b.
Take off the water retaining sheet.
i.
Cut off the wire binder and pull out the
indoor tube temperature sensor.
ii. Remove one grounding screw.
iii. Remove the wiring terminals of motor
and stepping motor.
iv. Remove the electric box assy.
v. Remove the screws locking each lead
wire.
c. Rotate the electric box assy. Twist off
the screws locking the wire clip and
loosen the power cord. Remove the
wiring terminal of power cord. Lift up
the main board and take it off.
Instruction: Some wiring terminal of
this product is with lock catch and other
devices.
The pulling method is below:
1. Remove the soft sheath for some
terminals, hold the circlip and then pull
out the terminals.
2. Pull out the holder for some terminals
(holder is not available for some wiring
terminal, hold the connector and pull the
terminal.
Indoor tube
temperature s ensor
Main
board
W i ring
terminal
of motor
W iring
terminal
of stepping
motor
S crew
G rounding
s c rew
W ire binder
S crew
W ire clip
P ower cord