30
PROGRAMMING
TRANSITION TEMPERATURE SETTING
Customizes how the device will ramp up in levels when
triggered ON by temperature in AUTO MODE. Set a
transition threshold to determine how much the probe
temperature would need to surpass your trigger point
for the device to increase in level by one. The higher
the transition threshold figure is set to, the more the
probe temperature would need to surpass your set
temperature trigger for the level to increase. The lower
the figure, the less the probe temperature would need
to surpass your set temperature trigger for the level to
increase. If the figure is set to zero, it will jump to your
maximum set level without ramping when triggered ON.
Press the up or down button to cycle through 0°F to 8°F
(0°C to 4°C) and set a transition threshold. The level
will be set one level above the OFF Mode level when
the sensor temperature first meets or exceeds the
high temperature trigger. For every transition threshold
crossed, the level will ramp up by one level, up until it
reaches the level set in ON Mode.
In this example, your high temperature trigger is set at
80°F, the OFF Mode level is 0, and the ON Mode level
is 6. If the transition threshold is set to 0°F, then the
devices will trigger to run at level 6 when the sensor
temperature meets or exceeds 80°F. However, if the
transition threshold is set to 2°F, then the devices
will trigger to run at level 1 when it meets or exceeds
80°F. It will then step up to level 2 when meeting or
exceeding 82°F, level 3 at 84°F, level 4 at 86°F, and
level 5 at 88°F. From 90°F on, it will run at level 6, the
level set in ON Mode.
Level